8.3.1
ADD-ACTDA
Create the feature-specific user data in the database.
Procedure Overview
Command Code
Parameter
ADD-ACTDA
TYPE=STN,STNO=<number>,
FEATCD=FWD,CFVAR=<param>,DTYPE=<param>,
[ITYPE=<param>],SI=<param>,[DESTNO=<key-num>];
| FEATCD=DND;
| FEATCD=CWT;
| FEATCD=VCR;
| FEATCD=RNGXFER;
| FEATCD=REPSECR;
| FEATCD=REMIND,REMIND=<number>;
| FEATCD=OPTISET,{(min1)RINGVOL=<number>,
RINGSOUN=<number>,ALERTVOL=<number>,
CALLVOL=<number>,SPKRVOL=<number>,
ROOMCHAR=<param>,DISPCONT=<number>,
ROLLVOL=<number>,SLKCONT=<number>};
| FEATCD=RCUTOFF;
| FEATCD=VARRING,[RNGTIME=<number>];
|TYPE=ATNDGR;ATNDGR=<number>,
{(min1)[NOPT=<number>],[ACT=<param>]};
|TYPE=ITR,[ITR=<number>],FEATCD=<param>;
|TYPE=MOBHFA,
| ACTION=MLOGON, HOMESTNO=<key-num>,
HOMEPIN=<string>, VISSTNO=<number>;
| ACTION=MLOGOFF, HOMESTNO=<key-num>,[COND=<param>];
Note:
If no entry is made for parameter ACT in the branch ATNDGR, the entered night option will be preselected, but not activated.
Call forwarding is not allowed between subscribers (source and destination) who belongs to the same ONS group.
Examples
1.
Enter a variable call-forwarding destination (and activate) and enter a timed reminder for STN 62850.
Input:
ADD-ACTDA:STN,62850,FWD,STATIONV,CFU,GEN,VCE,63627;
ADD-ACTDA:STN,62850,REMIND,01130;
2.
Activate night option 3 for ATND group 2.
Input:
ADD-ACTDA:ATNDGR,2,3,ACT;
Output:
H04 : NIGHT SWITCH FOR ATND GROUP 2 ACTIVATED.
3.
Set maximum number of rings until call forwarding is executed.
Input:
ADD-ACTDA:TYPE=STN,
STNO=37278
,
FEATCD=FWD
,CFVAR=STATIONV,DTYPE=CFNR,ITYPE=GEN,SI=VCE,DESTNO=32149;
ADD-ACTDA:TYPE=STN,
STNO=37278
,
FEATCD=VARRING
,
RNGTIME=10
;
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.