12.3.1
ADD-ANUM
The system number is entered only in those database subsystems that can contain customer-specific data. Already existing entries are overwritten. If single values are entered for the parameter SUSY, i.e., a system number is not to be entered in all DB subsystems; thus the system numbers of the DB subsystems not to be processed are compared with the newly entered number and the advisory H01 is issued in case of discrepancies. An empty database is initialized with "EMPTY DB ZDBxxxxx". In addition, the SP code number entered in the DIR file on hard disk for the corresponding APS can be changed by specifying the parameter SP.
Note
The system number (SYSNO) is defined during the SP production; a subsequent change (via ADD) is not permitted.
Procedure Overview
Command Code
Parameter
ADD-ANUM
TYPE=SYSNO,[UNIT=<param>],SYSNO=<string>;
|TYPE=SP,APS=<string>,SP=<string>;
Examples
The system number is to be entered into the database of the ADS.
Input:
ADD-ANUM:SYSNO,A1,"L31617S0001X ";
The SP number P30252B1111A00101 is to be entered in the DIR file of the APS A6-E50AC.
Input:
ADD-ANUM:SP,"A0-EJ0AC","P30252B4100A50401";
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.