18.4
Parameter Description
ANS
Answer
Type of Input
:
Single value
optional
Possible Values
:
(TEST, COPY and OUTPUT)
Y
= Yes
N
= No
Possible Values
:
(DISPLAY)
Y
= SUBSYSTEM
N
= FUNCTION FOR CURRENT FILE NOT CARRIED OUT
C
= PROCEED WITH FUNCTION FOR ALL FOLLOWING FILES
I
= DIRECTORY FILE
DESTDEV
name of the destination device
name of the HD-area on which the program library is located
Type of Input
:
Single value, optional
Possible Values
:
logical area name (3 to 9 characters)
Default Value
:
":PDS:"
DIRNAME
Name of directory file
Type of Input
:
Single value, max. 8 linked single values (TEST)
Single value (DUMP)
optional
Possible Values
:
Filename on data carrier max. 17 chars. (TEST)
Filename in PGLIB (DUMP).
FILENAME
Filename of MML CMD file
Type of Input
:
Single value
mandatory (DISPLAY, OUTPUT, DUMP)
optional (TEST)
Possible Values
:
File name (max. 32 chars.)
Part of file name, describes type of production
file (TEST)
Default Value
:
(TEST)
:BF0:
LANAME
Logical area name
Type of Input
:
Single value
optional
Possible Values
:
logical area name (3 to 9 chars.)
Default Value
:
:DBDA:
MODE
Desrired test mode
Type of Input
:
Single value
optional
Possible Values
:
NORMAL
Normal test
DBNORM
Normal test with database
DBONLY
Database only
DELETE
Delete program system or SELE
FORCE
Forced test
NALL
Normal test, all
NALLDB
Normal test, all and database
FALL
Forced test, all
FGEN
Forced test
NGEN
Normal test
Default Value
:
Normal test
OLDDIR
Old directory file against which delta is created
Type of Input
:
Single value
mandatory
Possible Values
:
File name (max. 32 chars.)
SELE
Name of the selection for status output (DISPLAY).
Name of the selection to be transferred/deleted. (TEST)
Type of Input
:
Single value
optional
Possible Values
:
Name of a selection (max. 8 chars.)
SP
Name of system program
Type of Input
:
Single value
mandatory (DISPLAY, TYPE=PSGL,SUSY)
optional (DISPLAY, TYPE=SELE)
optional (DISPLAY, TYPE=PSALL,SELE)
Possible Values
:
system program name (max. 8 chars.)
SUSY
Name of subsystem, for which status display is required. (DISPLAY)
Name of database to be dumped. (DUMP)
Type of Input
:
Single value
mandatory (DISPLAY, TYPE=SUSY)
Possible Values
:
Subsystem name (max. 8 chars.)
TYPE
Desired software load upgrade option
Type of Input
:
Single value
optional
Possible Values
:
(DISPLAY)
ALL
All DISPLAYED files
PSALL
All system programs
PSGL
One system program
SUSY
Subsystem
DIR
Directory file
Possible Values
:
(DUMP)
PS
All program systems
DB
Database subsystems
GEN
Forced test according to cartridge
DELTA
DUMP-APS creates deltas to old directory
Default Value
:
PSALL
(DISPLAY)
PS
(DUMP)
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.