26.4
Parameter Description
APPL
Application name
Type of Input
:
Single value, optional
Possible Values
:
Valid name (8 chars.)
Default values, depending on loadware:
TTYBSC, IBM, VMRTCO01, TTX01,
FAX01
ISOV24, S0D, UTC,
XLWV24, XLWU*
PSIODAT
CONF
Type of configuration
Type of Input
:
Single value, mandatory
Possible Values
:
SW: Software configuration
HW: Hardware configuration
STYPE = shelf configuration
DPP = Data-Processor-Ports
INS
Board to be activated
Type of Input
:
Single value, optional
Possible Values
:
Y,N
Default Value
:
N
LCXNO
LCX-Number
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 7
LINE
physical Line
Type of Input
:
Single value, mandatory
Possible Values
:
9 to 11
LTG
Line Trunk Group
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 32
LTU
Line Trunk Unit
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 15
LW
Loadware
Type of Input
:
Single value, mandatory
Possible Values
:
TTYBSC, IBM, VOICE, TTX, FAX,
ISOV24,UTC,
S0D,
XLWV24, XLWU*
PARTNO
Part number for a SWU line module
(this is marked on the front panel of each module
and can thus also be read if the module is already plugged in).
Type of Input
:
Single value, mandatory
Possible Values
:
Valid part number (10 chars.)
PARTNO01
The part number must be entered for each line module and slot (this is marked on the
front panel of each module and can thus also be read if the module is already plugged in).
Type of Input
:
Single value, mandatory
Possible Values
:
Valid part number (10 chars.)
PARTNO02
The part number must be entered for each line module and slot (this is marked on the
to
front panel of each module and can thus also be read if the module is already plugged in).
PARTNO05
Type of Input
:
Single value, optional
Possible Values
:
Valid part number (10 chars.)
RMX
Port assignment for RMX
Type of Input
:
Single value, mandatory
Possible Values
:
Y = Port is for RMC/CMS reserved
N = Port is for RMX blocked
SLOT
The slot must be specified for each line module in the SWU shelf.
Type of Input
:
Type of Input
Possible Values
:
1 to 121
SLOT01
The slot must be specified for each line module of the specified server. The maximum
hardware configuration allows for 5 line modules per server.
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 127
SLOT02
The slot must be specified for each line module of the specified server. The maximum
SLOT05
hardware configuration allows for 5 line modules per server.
Type of Input
:
Single value, optional
Possible Values
:
1 to 127
SCONF
shelf configuration
Type of Input
:
Single value, optional
Possible Values
:
WITH
: 1st LBU with LBC and LCU function
WITHOUT
: 1st LBU with LBC function only
MONO
: simplex mono running mode
MULTI
: simplex dual running mode and dual running mode
Default Values
:
WITHOUT
: "B5301-X "
"B5316-X "
"B5317-X "
"B5318-X "
"B5325-X "
WITH
: "B5331-X "
"B5332-X "
"B5333-X "
"B5337-X "
"B5338-X "
"B5339-X "
"B5350-X "
"B5351-X "
"B5384-X "
"B5387-X "
"B5391-X "
"B5391-A "
"Q5361-X "
"Q5365-X "
"Q5377-X "
"Q5380-X "
"Q5382-X "
MULTI
: "B5350-X "
: "B5384-X "
MONO
: "X7659-X "
MULTI
: "X7659-X "
In EC there is the same default value as in BC.
SPARTNO
Part number of basic or extension shelf (depending on parameter TYPE)
Type of Input
:
Single value, mandatory
Possible Values
:
Valid part number (10 chars.)
TYPE
Shelf type
Type of Input
:
Single value, mandatory
Possible Values
:
BC : Basic shelf
EC : Extension shelf
SWU : Line Board in the SWU
DPP : Data-Processor-Ports
UNIT
Functional system unit, i.e. server code
Type of Input
:
Single value, optional
Possible Values
:
A1 = Administration and Data Server (ADS)
${DocTitle}