28.5
Parameter Description
ACTNETIF
Activate network interface
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible values
:
EXTLAN1
NONE
External LAN
None
Default value
:
-
ATMADDR
ATM source address
Type of Input
:
single value,
mandatory (ADD)
optional (CHANGE)
Possible Values
:
15 digits, 0-9
Default Value
-
ATMNPI
Numbering plan identifier of ATMADDR
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
ISDN
NSAP
nsap-e.164
nsap-e.164
Default value
:
NSAP
ATMPROT
ATM protocol
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
UNI31
UNI40
UNITEST
UNI 3.1 protocol
UNI 4.0 protocol
"back to back" connection without atm network
Default value
:
UNI31
The value UNITEST is allowed only in operating mode NW20.
DESTTYPE
Type of destination
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible values
:
NET
HOST
Destination address in the network
Host destination address
Default value
:
-
FIREWALL
Firewall check
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible values
:
MAC
NONE
MAC address check
None
Default value
:
-
IPADDR
IP address (Ex. 192.168.1.4)
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE, DELETE)
Possible values
:
up to 15 characters, 0-9 and ’.’
Default value
:
-
Form: nnn.nnn.nnn.nnn, nnn=(0..255), leading zeros are not required
IPADRNEW
IP address (Ex. 192.168.1.4)
Type of input
:
Single value, optional (CHANGE)
Possible values
:
up to 15 characters, 0-9 and ’.’
Default value
:
-
Form: nnn.nnn.nnn.nnn, nnn=(0..255), leading zeros are not required
IPNMASK
IP network mask (Ex. 255.255.255.0)
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible values
:
up to 15 characters, 0-9 and ’.’
Default value
:
-
Form: nnn.nnn.nnn.nnn, nnn=(0..255), leading zeros are not required
LANHW
Hardware interface for external LAN port
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible values
:
WESTERN
COAX
AUI
Western-PLUG (10BASET)
COAX (10BASE2)
CANNON
Default value
:
-
L1MODE
Mode of ATM Layer 1
interface
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
SONET
SDH
Synchronous Optical Network
Synchronous Digital Hierarchy
Default value
:
SDH
LTG
LTG number
Type of input
:
Single value, optional
Possible values
:
1
Default value
:
1
LTU
LTU number
Type of input
:
Single value,
mandatory (ADD, CHANGE, EXEC)
optional (DISPLAY, REGENERATE)
Possible values
:
1-15, 17-99
1 to 15 in Hicom Host, 17-99 in AP shelves
Default value
:
-
MACADDR
MAC address (Ex. 00.6B.8C.CC.9B.7F)
Type of input
:
Single value, mandatory (ADD)
optional (CHANGE)
Possible values
:
up to 17 characters, 0-9, A-F and ’.’
Default value
:
-
Form: nn.nn.nn.nn.nn.nn, nn=(0..x’FF), 2-digit hexadecimal numbers
MAXTU
Maximum size of a transmission unit
Type of input
:
Single value, optional (ADD, CHANGE)
Possible values
:
256-1500
Default value
:
1500
NEXTROUT
Next router IP address (Ex. 195.4.5.1)
Type of input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible values
:
up to 15 characters, 0-9 and ’.’
Default value
:
-
Form: nnn.nnn.nnn.nnn, nnn=(0..255), leading zeros are not required
OPMODE
Operating mode, branching parameter
Type of Input
:
single value,
mandatory (ADD; CHANGE)
optional (DISPLAY)
Possible Values
:
GLOBAL
NW20
Global module data
Global and networking 2.0 data
Default Value
-
PATTERN
Idle bit pattern for the b-channels
Type of input
:
Single value, optional
group parameter (CHANGE)
Possible values
:
0-255
Default value
:
213
= H’D5
PORTBRD
Port number of the WAML2 module
Type of input
:
Single value,
mandatory (ADD),
optional (CHANGE)
Possible values
:
0-65535
Default value
:
-
PORTTCS
Port number of TC server
Type of input
:
Single value,
mandatory (ADD),
optional (CHANGE)
Possible values
:
0-65535
Default value
:
-
REASBUF
Reassembly buffer size (multiple of 125 microseconds)
Type of Input
:
single value, optional
Possible Values
:
0-128
See text of H26.
Default Value
16
Reassembly Buffer Size defines the total size of a buffer for reassembly of the data stream. The first byte of a new incoming data stream will be processed after the buffer is half full. Thus the Cell Delay Variation Tolerance based on the first incoming cell is 0.5 * Reassembly Buffer Size. The worst case CDVT, assuming that the first cell comes with maximum CDV is
0.25 * Reassembly Buffer size.
SIGVPI
Signalling VPI
Type of input
:
Single value, optional
group parameter (CHANGE)
Possible values
:
0-7
Default value
:
0
SLOT
Slot number of a LTU
Type of input
:
Single value,
mandatory (ADD, CHANGE, EXEC)
optional (DISPLAY, REGENERATE)
Possible values
:
1-121
A suitable module must be configured for the slot addressed by PEN (AMO BCSU).
SRCGRP
Source group index
Type of input
1 to 2 single values, concatenated with "&"
optional
Possible values
1 - 255
TABTYPE
Type of table
Type of input
:
Single value,
mandatory (ADD, CHANGE, DELETE)
optional (DISPLAY, REGENERATE)
Possible values
:
GLOBAL
NETWORK
IPROUTE
FIREMAC
MACADDR
ALL
Global parameter table
Network interface table
IP routing table
Firewall MAC address table
Display MAC address of WAML2
All
TRACELV
Trace and logging functions
Type of input
:
Single value, optional (ADD, CHANGE)
Possible values
:
0-255
Default value
:
3
TYPE
Board type, branching parameter
Type of input
:
Single value, mandatory (ADD, CHANGE, DELETE,DISPLAY)
optional (REGENERATE)
Possible values
:
STMA
WAML2
STMA module
WAML2 module
Default value
:
-
VCIOFS0
VCI offset for VPI0
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS1
VCI offset for VPI1
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS2
VCI offset for VPI2
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS3
VCI offset for VPI3
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS4
VCI offset for VPI4
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS5
VCI offset for VPI5
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS6
VCI offset for VPI6
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VCIOFS7
VCI offset for VPI7
Type of input
:
Single value, optional
Group parameter (CHANGE)
Possible values
:
0 - 127
Default value
:
0
VPCI0..7
VPCI for VPI0..7
Type of Input
:
single value,
optional
Possible Values
:
0-65535
Default Value
0..7
Default value is always the VPI number.