44.3
Parameter Description
ALLOC
Allocation/assignment EXEC <-> SECR.
If no allocation is made in the parameter, that executive is assigned to the first secretary (or to the second, if a dummy number was entered for the first).
Type of Input
:
linked single values
maximum of 4 values permitted
optional
Possible Values
:
E1S1, E2S1, E3S1, E4S1, E1S2, E2S2, E3S2, E4S2
EXEC
Executive station number
The sequence in which the values are entered is important for the allocation EXEC <-> SECR and EXEC <-> MBOX1 to MBOX4
Type of Input
:
single values,optional (CHANGE,DELETE)
single values, required (CHANGE, TYPE=EXECATTR)
maximum of 4 linked single values, required (ADD)
Possible Values
:
1-6 positions, decimal
GRNO
Number of the executive/secretary arrangements
Type of Input
:
single value
optional (ADD)
required (CHANGE, DELETE, DISPLAY, REGENERATE)
Possible Values
:
1 up to 1000
KEY
type of the key on the device
Type of Input
:
single value
required (CHANGE)
Possible Values
RNGXFER1
for EXECSLK
RNGXFER1,
RNGXFER2,
RNGXFER3,
RNGXFER4,
PUS1,
PUS2,
PUS3,
PUS4
for SECRSLK
MBOX
Mailbox for active FWD/RNA
Type of Input
single value
required (CHANGE)
Possible Values
NONE
no mailbox assignment
EXEC
call routed into executive’s mailbox
SECR
call routed into secretary’s mailbox
MBOX1
Mailbox for active FWD/RNA for Executive 1 to 4
MBOX2
Type of Input
single value
MBOX3
optional (ADD)
MBOX4
Possible Values
NONE
no mailbox assignment
EXEC
call routed into executive’s mailbox
SECR
call routed into secretary’s mailbox
Default Value
NONE
MULTN
Multi-tone ring for calls between the executive and the secretary
Type of Input
:
single value
optional (ADD)
required (CHANGE)
Possible Values
:
Y, N
NEWEXEC
New executive station number
Type of Input
:
single value, required
Possible Values
:
1-06 positions, decimal
NEWSECR
New secretary station number
Type of Input
:
single value, required
Possible Values
:
1-06 positions, decimal
NOTRNG
Delayed notification tone ring
Type of Input
:
single value, optional
Possible Values
:
NONE
= no notification
ON3
= with multiple burst notification in all states
ONIDLE3
= multiple burst notification in idle state only
ON1
= single burst notification in all states
ONIDLE1
= single burst notification in idle state only
Default Value
:
ON3
OLDEXEC
Old executive station number
Type of Input
:
single value, required
Possible Values
:
1-6 positions, decimal
OLDSECR
Old secretary station number
Type of Input
:
single value, required
Possible Values
:
1-6 positions, decimal
REP
Representative or deputy secretary station number.
The sequence in which the values are entered is important for the allocation SECR <-> REP (ADD).
Type of Input
:
single value, optional (CHANGE, DELETE)
1-2 linked single values, optional (ADD)
Possible Values
:
1-6 positions, decimal
SECR
Secretary station number
The sequence in which the values are entered is important for the allocation EXEC <-> SECR.
Type of Input
:
1-2 linked single values, required (ADD)
single value, required (CHANGE)
single value, optional (DELETE)
Possible Values
:
1-6 positions, decimal
SLKTEXT
SLK Text
Type of Input
:
single value, mandatory
Possible Values
:
text string upto 12 characters
= individual text
SLKTYPE
type of SLK
Type of Input
:
single value, mandatory
Possible Values
:
SLKSTNO
= display of subscriber number
SLKNAME
= display of subscriber name (from amo persi)
SLKTEXT
= display of individual text
STNO
Station number
Type of Input
:
single value, required
Possible Values
:
1-6 positions, decimal
TYPE
Branching parameter
Type of Input
:
single value, required
Possible Values
:
ADDSTN, EXEC, SECR, EXECSLK, SECRSLK, MULTN, EXECATTR (CHANGE)
SYS, GR, STN (DISPLAY, REGENERATE)
SYS, GR (DELETE)
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.