51.3.1
ADD-CONSY
This function is used to add data to the system configuration table. This data is used for outputs of system layout plan and for physical error messages.
1.
OPT=CAB: Add cabinet data.
2.
OPT=FRAME: Add frame (=module frame) data.
Frame data may only be entered if the cabinet data has already been added (OPT = CAB).
FlexPack- construction (600ECS):
To distinguish the FlexPack -construction from the ordinary 600ECX-construction following pseudo-cabinets have been established:
basic-cabinet C600ECS partnumber: G5298-X
expansion-cabinet C600ECS1 partnumber: G5285-X
power-control-cabinet C600PC partnumber: G5401-X
These cabinets are fictive, therefore the partnumber which hase been "borrowed" by the cabinets of the 600ECX- resp. the 80DSC-construction is also just a pseudo-partnumber.
For the 600ECS-configuration only the frames LTUW and L80XF are possible, whereas for the 600ECX-configuration only LTUW, resp. for the 80CXE the frames CC80F and L80XF are allowed.
Example for ECS-configuration see DISPLAY-CONSY.
Except the ECS-pseudo cabinets also a pseudo-cabinet has been introduced for the 80CXE-configuration. The cabinet has been defined als follows:
C80CXE partnumber: G5284-X
Procedure Overview
Command Code
Parameter
ADD-CONSY
ADDR=<string>,OPT=CAB\FRAME
|
,OPT=CAB,CAB=<string>;
(1)
|
,OPT=FRAME,SHELFNO=<number>,FRAME=<string>
(2)
,[LTU=<number>],[PID=<param>];
Example
1.
Add cabinet C1 under address P205.
Input:
ADD-CONSY: P205,CAB,C1;
2.
Add 600ECS (Flex Pack-configuration)
Input:
ADD-CONSY: "P101",CAB,"C600PC ";
ADD-CONSY:"P101",FRAME,1,"PSD ",,;
ADD-CONSY:"P101",FRAME,2,"PSD ",,;
ADD-CONSY:"P102",CAB,"C600ECS ";
ADD-CONSY:"P102",FRAME,1,"CCDAXD1 ",,"BPA"&"BPB"&"A1";
ADD-CONSY:"P102",FRAME,2,"L80XF ",1,;
ADD-CONSY:"P102",FRAME,3,"LTUW ",2,;
ADD-CONSY:"P102",FRAME,4,"L80XF ",3,;
ADD-CONSY:"P103",CAB,"C600ECS1";
ADD-CONSY:"P103",FRAME,1,"LTUW ",4,;
ADD-CONSY:"P103",FRAME,2,"LTUW ",5,;
ADD-CONSY:"P103",FRAME,3,"LTUW ",6,;
ADD-CONSY:"P103",FRAME,4,"L80XF ",7,;
ADD-CONSY:"P104",CAB,"C600ECS1";
ADD-CONSY:"P104",FRAME,1,"L80XF ",8,;
ADD-CONSY:"P104",FRAME,2,"L80XF ",9,;
ADD-CONSY:"P104",FRAME,3,"L80XF ",10,;
ADD-CONSY:"P104",FRAME,4,"L80XF ",11,;
ADD-CONSY:"P105",CAB,"C600ECS1";
ADD-CONSY:"P105",FRAME,1,"L80XF ",12,;
ADD-CONSY:"P105",FRAME,2,"L80XF ",13,;
ADD-CONSY:"P105",FRAME,3,"L80XF ",14,;
ADD-CONSY:"P105",FRAME,4,"L80XF ",15,;
3.
Add cabinet CAB-NBB under address P106 and the shelf BP-NBB, AP-range.
ADD-CONSY:"P106",CAB,"CAB-NBB ";
ADD-CONSY:"P106",FRAME,1,"BP-NBB ",34;