51.4
Parameter Description
ADDR
Cabinet address
Type of Input
:
Single value,
mandatory (ADD, CHANGE, COPY, DELETE)
optional (DISPLAY, REGENERATE)
Possible Values
:
4 chars., alphanumeric
ADDRNEW
New cabinet address
Type of Input
:
Single value,
mandatory
Possible Values
:
4 chars., alphanumeric
ASSEMBLY
HW type
Type of Input
:
Single value,
optional
Possible Values
:
NONCOMP, COMPACT, EXTCOMP, ECX, ECDSC, ECCXE
BDIDX
Rel. board index
This index is important, if the same boards are used more than once in central SWU-Frames
(e.g. MTS-, MBU- or MEM-boards) and signs the sequence of their use within the frame.
Processes, which use the HW-data (e.g. AMO SDSU, SIT), need this index to address
the different data bases.
Type of Input
:
Single value,
optional
Possible Values
:
0 - 255
BOARD
Name of the board
Type of Input
:
Single value,
optional
Possible Values
:
maximum 8 alphanumeric characters
CAB
Cabinet name
Type of Input
:
Single value
mandatory (ADD, CHANGE, COPY, DELETE, REGENERATE)
optional (DISPLAY)
Possible Values
:
maximum 8 alphanumeric characters
(possible cabs are in SHB, Volume 1, Reg.2, Chapter 4)
CLASS
Classification of HICOM
Type of Input
:
Single value,
optional
Possible Values
:
H40, H80, (beginning at SP300-V3.3)
H180, H600, H3000, H3000E
CS
Board type
Type of Input
:
Single value
optional
Possible Values
:
CCD, CCG, CCH, DPCC, GP, IOCC, IOCG, IPCC, LTGCONF,
LTGDCL, LTGMEM, LTGMTS, LTGSIU, LTUBG, LTUC, LTUR, MBU,
MD, MEMCOM, MEMLOC, MTSGSCS, NOTDEF, PCG, PSCC,
PSCSN, PSLTG, PSLTU
FRAME
Frame name
Type of Input
:
Single value
mandatory (ADD, CHANGE: OPT=BOARD)
optional (CHANGE: OPT=FRAME)
Possible Values
:
maximum 8 alphanumeric characters
(possible frames see Service Manual in the "Hardware Survey" chapter)
HALF
Half of system unit
Type of Input
:
Single value
optional
Possible Values
:
A, B
IDX
Index of board on the shelf (look at mask of display)
Type of Input
:
Single value
mandatory
Possible Values
:
1 - 30
LTU
LTU number
Type of Input
:
Single value
optional
Possible Values
:
1 - 99
OPT
Branching parameter (ADD,CHANGE)
With the aid of this parameter, the user can specify the type of
data to be accessed (cabinet type data or frame type data).
Type of Input
:
Single value
mandatory
Possible Values
:
CAB
= Cabinet type data
FRAME
= Frame type data
BOARD
= Board data
Branching parameter (DISPLAY)
With the aid of this parameter, the user can specify the type of data to be accessed
Type of Input
:
Single value
mandatory
Possible Values
:
CAB
= data of a complete HICOM
CABTYPE
= Cabinet-type-data
FRAMTYPE
= Frame-type-data
PEN
Port equipment number
Type of Input
:
Single value
optional
Possible Values
:
1 - 121
A suitable module must be configured for the slot addressed by PEN (AMO BCSU).
The possible Slot values for PEN depend on the systems architecture and can be found in the BCSU AMO description.
PID
Processor ID
In the case of GP or IOC processors, the IDs of both halves are added.
Type of Input
:
maximum 3 linked single values
optional
Possible Values
:
BPA,BPB
CC half
GP1A - GP32A
LTG half
GP1B - GP32B
LTG half
IOC1A - IOC4A
CSN half
IOC1B - IOC4B
CSN half
A1
Administration and Data Server
SHELFNO
Shelf number
Type of Input
:
Single value
mandatory (ADD, CHANGE)
optional (DELETE)
Possible Values
:
1 - 14
SHELFNEW
New shelf number
Type of Input
:
Single value
optional
Possible Values
:
1 - 14
The parameters CS, BOARD, PEN, HALF and BDIDX form a parameter group of which at least 1 must be entered.
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.