60.2.2
DISPLAY-CTIME
Procedure Overview
Command Code
Parameter
DISPLAY-CTIME
TYPESWU=<param>;
Example
Interrogate the customer-specific timers for call processing part 1:
Input:
DISPLAY-CTIME:CP1;
Output:
CALL PROCESSING TIMERS 1:
+-----------------------+-----------------------+-----------------------+
| USERGD2 = 2 SEC. | USERGD5 = 5 SEC. | LONGPATH = 2 SEC. |
| CBK = 20 SEC. | ANSADV = 20 SEC. | PARK = 30 SEC. |
| SPDPD = 5 SEC. | RECALL = 30 SEC. | CDRDISDE = 10 SEC. |
| ECCSSUPV = 15 SEC. | FAXCD = 5 SEC. | DCIEOD = 5 SEC. |
| AUTOTONE = 200 MS. | RELREC = 90 SEC. | TSUPVCB = 2 SEC. |
| ONHOOK = 15 MIN. | TSUPVAUT = 30 SEC. | CBRLEN = 40 SEC. |
| KNLEN = 30 SEC. | RELCON = 90 SEC. | LCREOD = 10 SEC. |
| RECNIGHT = 180 SEC. | RECPARK = 120 SEC. | PINVO1 = 300 SEC. |
| PINVO2 = 300 SEC. | PINVO3 = 300 SEC. | PINVO4 = 300 SEC. |
| PINVO5 = 300 SEC. | PINVO6 = 300 SEC. | PINVO7 = 300 SEC. |
| PINNV1 = 1800 SEC. | PINNV2 = 1800 SEC. | PINNV3 = 1800 SEC. |
| PINNV4 = 1800 SEC. | PINNV5 = 1800 SEC. | PINNV6 = 1800 SEC. |
| PINNV7 = 1800 SEC. |
DISPCH = 20 SEC.
| OFLPM = 20 SEC. |
| ATDLYANN = 12 SEC. | DANNDIAL = 15 SEC. | ANNDIAL = 5 SEC. |
| LCRET = 5 SEC. | NOTRNG = 5 SEC. | FAXOFLPM = 30 SEC. |
| ROUTEREQ = 5 SEC. | CTHLDREC = 300 SEC. | UUS3T1 = 10 SEC. |
| UUS3T2 = 10 SEC. | UUS3T3 = 10 SEC. |
QDELESTA = 1 SEC.
|
+-----------------------+-----------------------+-----------------------+
Example
Interrogate the customer-specific timers for call processing part 2:
Input:
DISPLAY-CTIME:CP2;
Output:
CALL PROCESSING TIMERS 2:
+-----------------------+-----------------------+-----------------------+
| CCBS5 = 3600 SEC. | AOCT1 = 15 SEC. | AOCT2 = 15 SEC. |
| CTLS1 = 2 SEC. | CTLS2 = 2 SEC. | GPUNST = 1800 SEC. |
| DCPA1 = 10 SEC. | DCPA2 = 15 SEC. | DCPA3 = 10 SEC. |
| RTAD = 0 SEC. | PINVO10 = 300 SEC. | PINNV10 = 1800 SEC. |
| T400 = 20 SEC. | PREDCALL= 20 SEC. | NIRECALL= 900 SEC. |
| TRKTOTRK= 120 SEC. | REPAUSE = 3 SEC. | SYSRCPAR= 30 SEC. |
| AUTCMPON= 60 SEC. | PINVO11 = 300 SEC. | PINNV11 = 1800 SEC. |
| PINVO12 = 300 SEC. | PINNV12 = 1800 SEC. | PINVO13 = 300 SEC. |
| PINNV13 = 1800 SEC. | PINVO14 = 300 SEC. | PINNV14 = 1800 SEC. |
| PINVO15 = 300 SEC. | PINNV15 = 1800 SEC. | VARDIALT= 20 SEC. |
| FTRQTOUT= 10 SEC. | FTWOTOUT= 180 SEC. | GWNAVAIL= 60 SEC. |
| SMPFTIME= 8 SEC. | | |
+-----------------------+-----------------------+-----------------------+
Example
Interrogate the customer-specific timers for trunks:
Input:
DISPLAY-CTIME:TRK;
Output:
CCT/SET TIMERS:
+-----------------------+-----------------------+-----------------------+
| PREEMT = 90 SEC. | NOANSCON = 30 SEC. | NOCALLTR = 30 SEC. |
| ATNDTRNS = 30 SEC. | RPTSZ = 5 SEC. | RPTSZEND = 40 SEC. |
| PRREQI = 30 SEC. | PRREQC = 15 SEC. | NEWCONN = 110 SEC. |
+-----------------------+-----------------------+-----------------------+
Example
Interrogate the customer-specific timers for the attendant console:
Input:
DISPLAY-CTIME:ATND;
Output:
ATTENDANT CONSOLE TIMERS:
+-----------------------+-----------------------+-----------------------+
| ATNDCALL = 60 SEC. | ATNDCQ = 2 SEC. | ATNDHOLD = 5 SEC. |
| ATNDDIS = 20 SEC. | CQPRIO = 15 SEC. | CQOFL = 30 SEC. |
| ATNDTNSR = 7 SEC. | | |
+-----------------------+-----------------------+-----------------------+
Example
Interrogate the customer-specific timers for the multiple search code calling:
Input:
DISPLAY-CTIME:CCM;
Output:
MULTIPLE-CC TIMERS:
+-----------------------+-----------------------+-----------------------+
| NOTRDY1 = 3 SEC. | NOTRDY2 = 6 SEC. | WAIT1 = 1000 MS. |
| WAIT2 = 2000 MS. | CLRANS1 = 20 SEC. | CLRANS2 = 30 SEC. |
| CLRANS3 = 50 SEC. | CLRANS4 = 120 SEC. | |
+-----------------------+-----------------------+-----------------------+
Example
Interrogate the timers for the VECOTIME
Input:
DISPLAY-CTIME:VECOTIME;
Output:
VECO TIMERS:
+-----------------------+-----------------------+-----------------------+
| CBMNXTBD = 20 MIN. | CBMBDANS = 30 SEC. | |
+-----------------------+-----------------------+-----------------------+