72
DEFTM - Define Traffic Measurement
Interrelationships
Parameter Description
Functions of the AMO
Error Messages and Advisories
This AMO is used for
•
set up and administration of the DB table ’’list of measurement objects’’.
•
Starting and stopping of the measurement. In addition a switch (PMON) in the database of the ADP is used.
•
Determining the measurement range by the created parameters from the measurement object file.
The table ’’measurement objects’’ consists of two fields. These both fields together determine a range of objects:
•
lower boundary of the range of objects
•
upper boundary of the range of objects
The object area is described by its lower and upper boundary.
The switch ALLON states the fact that all objects, except processor load and the attendant console activity, are recorded by the measurement.
If no measurement objects are defined in the list of measurement objects, and the switch ALLON is set to N(o), no measurement takes place.
If measurement objects are defined in the list of measurement objects, and the switch ALLON is set to N(o), then the measurement of measurement objects of the list of measurement objects takes place.
Is the switch ALLON set to Y(es), all measurement objects are recorded. All entries of the list of measurement objects have no effect, are preserved however for a new measurement.
The user can make max. 500 entries into the list of measurement objects.
Measurement objects are:
•
subscriber number (range)
•
trunk number (range)
•
trunk group number (range)
•
attendant number (range)
•
attendant group number (range)
•
pilot number of a hunt group
General description
Parameter description for TRUNK
A trunk range TRUNK has a lower and upper limit value, whereby each limit value is structured as follows:
LTU-SLOT-CCT
If the entire possible trunk range is taken off, the value ANY is output.
The default value of parameters CCT, LTU and SLOT is set to ANY.
If only a subrange is covered for example by parameter LTU, then the entire area must be indicated for parameter CCT (see error messages F05 and F06 in
Section 72.4.1, “Error Messages”
)
The complete description of parameters CCT, LTU and SLOT see
Section 72.3, “Parameter Description”
.