72.3
Parameter Description
ACACTON
Events of attendant console (AC) will be monitored:
AC activates/deactivates nightservice,
AC pulls/reconnect the jack,
AC is out of/in service.
Type of Input
:
Single value, optional, 4. parameter of a min-1-group (CHANGE)
Possible Values
:
Y
= Yes
N
= No
Default Value
:
N
ALLON
All objects will be monitored, except processor load and attendant console activity.
If this switch is on, all settings in the list of measurement objects of AMO_DEFTM have no effect.
Is this switch not set, then the measurement of measurement objects of the list of measurement objects takes place.
Type of Input
:
Single value, optional, 2. parameter of a min-1-group (CHANGE)
Possible Values
:
Y
= Yes
N
= No
Default Value
:
N
ATNDGRNO
Attendant group number (AMO-VFGR)
Type of Input
:
Single value, required (ADD)
single value, optional (DELETE)
range, optional
Possible Values
:
0 to 15
CCT
Circuit number
Type of Input
:
Single value, optional
range, optional
Possible Values
:
0 to 255
LOADON
A special CDR record is generated every 10 seconds, containing processor load (SWU and ADP)
Type of Input
:
Single value, optional, 3. parameter of a min-1-group (CHANGE)
Possible Values
:
Y
= Yes
N
= No
Default Value
:
N
LTU
Line Trunk Unit
Type of Input
:
Single value, required (ADD)
single value, optional (DELETE)
range, optional
Possible Values
:
1 to 99
Note
:
LTU 16 is used Hicom internal.
NUMBER
Station number
Type of Input
:
Single value, required (ADD)
single value, optional (DELETE)
range, optional
Possible Values
:
max. 22 digits, digits 0 to 9
OBJECT
Add, delete and display of measurement object types
Type of Input
:
Single value, required (ADD, DELETE)
single value, optional (DISPLAY)
range, optional
Possible Values
:
ALL
= All objects (DELETE and DISPLAY only)
ATTND
= Attendant number
ATTNDGRP
= Attendant group number
HUNTHEAD
= Pilot number of a hunt group
TRUNK
= Trunk number
TRUNKGRP
= Trunk group number
SUBSCR
= Subscriber number
Default Value
:
ALL
= All objects (DISPLAY only)
PMON
Central switch for performance management (PM), needed to start/stop PM.
If this switch is off, all other settings of AMO-DEFTM have no effect.
Type of Input
:
Single value, optional, 1. parameter of a min-1-group (CHANGE)
Possible Values
:
Y
= Yes
N
= No
Default Value
:
N
SLOT
Specification of the mounting pitch in the LTU
Type of Input
:
Single value, optional
range, optional
Possible Values
:
1 to 121
TRKGRNO
Trunk group number (AMO-BUEND)
Type of Input
:
Single value, required (ADD)
single value, optional (DELETE)
range, optional
Possible Values
:
1 to 512