|Command Code | Parameters |
+-----------------+--------------------------------------------+
|REGENERATE-DIDCR | |TYPE=DID,[RULEIDX=<NUMBER>]; |
| | |TYPE=SRT,[SRTABLE=<number>]; |
| | |TYPE=SVC,NETSVC=<param>, |
| | [RULEIDX=<number>]; |
| | |
Example 1:
Output regeneration commands for rule index 1 and 2.
Input:
REGENERATE-DIDCR:DID,1&&2;
Output:
REGENERATE-DIDCR:DID,1&&2;
H500: AMO DIDCR STARTED
ADD-DIDCR:1,5,3;
ADD-DIDCR:2,6,3;
CHANGE-DIDCR:DID,2,1,1;
CHANGE-DIDCR:DID,2,2,22;
CHANGE-DIDCR:DID,2,3,333;
CHANGE-DIDCR:DID,2,4,4444;
CHANGE-DIDCR:DID,2,10,2;
CHANGE-DIDCR:DID,2,52,25;
CHANGE-DIDCR:DID,2,53,355;
CHANGE-DIDCR:DID,2,54,4555;
CHANGE-DIDCR:DID,2,94,2104;
CHANGE-DIDCR:DID,2,95,2105;
CHANGE-DIDCR:DID,2,96,2106;
CHANGE-DIDCR:DID,2,97,2107;
CHANGE-DIDCR:DID,2,98,2108;
CHANGE-DIDCR:DID,2,99,2109;
AMO-DIDCR-... DIRECT INWARD DIAL DIGIT_CONVERSION_RULE
REGENERATE EXECUTED;
Example 2:
Output regeneration commands for service rule table 1.
Input:
REGENERATE-DIDCR:SRT,1;
Output:
REGENERATE-DIDCR:SRT,1;
H500: AMO DIDCR STARTED
CHANGE-DIDCR:SRT,1,INWATS,1;
CHANGE-DIDCR:SRT,1,VDN,2;
CHANGE-DIDCR:SRT,1,INTLWATS,2;
AMO-DIDCR-... DIRECT INWARD DIAL DIGIT_CONVERSION_RULE
REGENERATE EXECUTED;
Example 3:
Output regeneration commands for Network Service INWATS MEG8, RULEIDX 1.
Input:
REGENERATE-DIDCR:SVC,INWATS,1;
Output:
REGENERATE-DIDCR:SVC,INWATS,1;
H500: AMO DIDCR STARTED
CHANGE-DIDCR:SVC,INWATS,1,0&&13,ANI;
CHANGE-DIDCR:SVC,INWATS,1,18&&21,SID;
CHANGE-DIDCR:SVC,INWATS,1,33,SIDPREF;
AMO-DIDCR-... DIRECT INWARD DIAL DIGIT_CONVERSION_RULE
REGENERATE EXECUTED;