76.2.1
ADD-DIMSU
This action allocates or changes the memory entries. The AMO verifies the input parameters and displays an advisory message showing the value update (ACTUAL) in case of a valid input.
The value ACTUAL determines the number of storage elements to be assigned.
The memory allocations are processed in the sequence of the parameters in the parameter tree.
If the requested memory space is insufficient for a specified parameter value, then an error message is output. The memory allocations processed before the error message are correct. The memory allocations processed for subsequent parameters after the error message are also correct if the memory space is sufficient.
If some of the assigned storage elements are no longer required for a parameter, the ACTUAL value can be reduced to the highest used element (MAX_USED). If no assigned storage element is used, the ACTUAL value can be reset to 0.
NOTE:
Exception, parameters CCIDXS and CCIDXD: These parameters can only be increased.
The following parameters use only dynamic memory. The default value should be used for these parameters (if necessary, the value can be increased).
ACDCQ, ACDLOGON, ATNDCQ, CBK, CFWHIST, COSTI, CPB, CPDBUF, DTITMD, GENBUF, HGMEMB, HT, HTCQB, LODS0, LODTMD, PINBUF, SILI, SYNAN
Procedure Overview
Command Code
Parameter
ADD-DIMSU
[TYPE=ADMCC],{CCIDXS=<number>,CCIDXD=<number>};
|[TYPE=ADMLTG],GPIDX=<number>;
|[TYPE=BASIC],{(min 1) STN=<number>, BUS=<number>
,OPTCC=<number>, OPTEXP=<number>, ATND=<number>
,ES=<number>, ESSTN=<number>, S2PP=<number>
,AUXDIGI=<number>, PRI=<number>, TRK=<number>
,CRCP=<number>, DPLNCD=<number>, DPLNGR=<number>
,RTE=<number>, MG=<number>, SG=<number>
,ATNDGR=<number>, HT=<number>, HTCQB=<number>
,CPB=<number>, SILI=<number>, COSTI=<number>
,LODEN=<number>, SU=<number>, NWBCHL=<number>
,LODS0=<number>, LODTMD=<number>, CPDBUF=<number>
,DTILTG=<number>, DTITMD=<number>};
|[TYPE=USER],{(min 1) NAME=<number>, EXTNAME=<number>
,ORG=<number>, COS=<number>, SPDI=<number>
,SPDCL=<number>, SPDCD=<number>, CBK=<number>
,REMIND=<number>, PUGR=<number>, ID=<number>
,PINBUF=<number>, CFWDEST=<number>, CFWHIST=<number>
,HGMEMB=<number>, CUGPROF=<number>, LIN=<number>
,COMGR=<number>, DSS=<number>, DSSNA=<number>
,KEYSYS=<number>, CALLOG=<number>, ATNDCQ=<number>
,NSTN=<number>, ALTROUT=<number>, LCRCOS=<number>
,SLKTEXT=<number>, CALLOGS=<number>, HOTDEST=<number>};
|[TYPE=NETWORK],{(min 1) MFCVAR=<number>
,DSPMOD=<number>, DPDSPMOD=<number>, LODR=<number>
,LROUT=<number>, LRTPROF=<number>, LCRDSR=<number>
,SYNAN=<number>, FORMTAB=<number>, VOICO=<number>
,BLK100=<number>, RSTCON=<number>, TEAMCONN=<number>
,DSS1SDRD=<number>, DSS1SCRP=<number>, REMPUGR=<number>
,PARTNODE=<number>, LDPLN1=<number>, LDPLN2=<number>
,LDPLN3=<number>, LDPLN4=<number>, LDPLN5=<number>
,LDPLN6=<number>, LDPLN7=<number>, LDPLN8=<number>
,LDPLNC1=<number>, LDPLNC2=<number>, LDPLNC3=<number>
,LDPLNC4=<number>, LDPLNC5=<number>, LDPLNC6=<number>
,LDPLNC7=<number>, LDPLNC8=<number>};
|[TYPE=APPLICAT],{(min 1) APPL=<number>, ECCS=<number>
,DCIPAR=<number>, WSPROT=<number>, INFO=<number>
,ACDAGT=<number>, ACDGRP=<number>, ACDLOGON=<number>
,ACDPRIM=<number>, ACDCQ=<number>, ACDRCG=<number>
,ACDRT=<number>, ACDRTX=<number>, ACDSHIFT=<number>
,ACDMONID=<number>, ACDCALEN=<number>, GDTR=<number>
,DNI=<number>, DPDNI=<number>, GENBUF=<number>};
|[TYPE=SYSTEM],{(min 1) PERMDL=<number>, CRICC=<number>
,WAML1=<number>, WAML2=<number>, STMA=<number>
,STMACIR=<number>, STMI=<number>, STMIHFA=<number>
,STMIHFA2<number>, STMI2IGW=<number>, SLC24=<number>
,AP=<number>, GWREG<number>, SCTPATH=<number>
,CCAP=<number>, APEGRP=<number>};
The branch-off parameter is optional. Only parameters of the same branch can be used in one ADD-command.
Example
Input:
ADD-DIMSU:OPTCC=1000;
Output:
ADD-DIMSU:OPTCC=1000;
H500: AMO DIMSU STARTED
H00: +--------------------------+
| OPTCC.ACTUAL : 1000 |
| .PREVIOUS: 500 |
+--------------------------+
AMO-DIMSU-170 DIMENSIONING OF FEATURES, SWITCHING UNIT
ADD COMPLETED;