77.5.2
INPUT-DISPA
The action INPUT-DISPA is only used for WRITE-READ access, and cannot be entered by the user at the administration and maintenance terminal (AMT). Only the text below is displayed at the AMT as an input request to the user (the asterisk which follows the text indicates the ready state):
DISPLAYER-INPUT IN <processor name> PLEASE:
*
This output text also indicates that the AMO has successfully executed the preceding command.
The following commands are possible:
CMD=
CHAR,CTYPE=<param>;
CMD=
COPY,CTYPE=DEF,[NAME=<string>],[AREA=<param>-<param>];
CMD=
COPY,CTYPE=DBL,[NAME=<string>];
CMD=
DEF,CTYPE=ADR,NAME=<string>,TYPE=ADR,ADR=<hex>-<hex>;
CMD=
DEF,CTYPE=ADR,NAME=<string>,TYPE=TBL,TBL=<string>
,IDX=<number>,DISPLACE=<number>;
CMD=
DEF,CTYPE=LOGNAME,NAME=<string>,AREA=<param>
,LEN=<number>,IDX=<number>&&<number>;
CMD=
DEL,CTYPE=DEF,[NAME=<string>],AREA=<param>;
CMD=
DIST,NO=<number>;
CMD=
DUMP,CTYPE=ADR,NAME=<string>,UNIT=<param>,NO=<number>;
CMD=
DUMP,CTYPE=DA,ADR=<hex>,UNIT=<param>,NO=<number>;
CMD=
DUMP,CTYPE=LOGNAME,NAME=<string>,IDX=<number>;
CMD=
E,FILE=<string>;
CMD=
END;
CMD=
EV,CTYPE=D,NO=<number>;
CMD=
EV,CTYPE=H,VAL=<hex>;
CMD=
FILE,FILE=<string>,[NO=<number>];
CMD=
LST,CTYPE=ADR,NAME=<string>,UNIT=<param>,NO=<number>;
CMD=
LST,CTYPE=DA,ADR=<hex>-<hex>,UNIT=<param>,NO=<number>;
CMD=
LST,CTYPE=DEF,[NAME=<string>],AREA=<param>;
CMD=
LST,CTYPE=INT,TYPE=<param>;
CMD=
LST,CTYPE=INT,TYPE=BCA;
CMD=
LST,CTYPE=INT,TYPE=BCASA,SEL=HD,FILE=<string>;
CMD=
LST,CTYPE=INT,TYPE=BCASA,SEL=SCREEN,[DISPLACE=<number>],
,[LEN=<number>],[CONTINUE=<param>];
CMD=
LST,CTYPE=LOGNAME,NAME=<string>,IDX=<number>;
CMD=
P,[PROCID=<param>];
CMD=
PATCH,CTYPE=ADR,NAME=<string>,UNIT=<param>
,NO=<number>,VAL=<hex>;
CMD=
PATCH,CTYPE=DA,ADR=<hex>,UNIT=<param>
,NO=<number>,VAL=<hex>;
CMD=
PATCH,CTYPE=LOGNAME,NAME=<string>,UNIT=<param>,
,NO=<number>,VAL=<hex>,IDX=<number>,DISPLACE=<number>;
CMD=
SET,CTYPE=ADR,NAME=<string>,UNIT=<param>
,NO=<number>,VAL=<hex>;
CMD=
SET,CTYPE=DA,ADR=<hex>-<hex>,UNIT=<param>
,NO=<number>,VAL=<hex>;
CMD=
SET,CTYPE=LOGNAME,NAME=<string>,UNIT=<param>,
,NO=<number>,VAL=<hex>,IDX=<number>,DISPLACE=<number>;
Notes
1.
The default setting of numbers by the AMO is ’H’ (hexadeximal), in other cases, the numbers are explicitly assigned the suffix ’T’ for decimal.
2.
Until otherwise specified after the AMO has been started, hexadecimal dump format is always displayed with the correspondig ASCII charakters (branch CHAR) and not interspersed with empty lines (branch DIST).
3.
The memory address has the same fomat for the commands LST, SET and DEF (ADR=<selektor>-<offset>).
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.