83.3.2
DEACTIVATE-DSSU
Deactivation can be carried out as follows:
•
with pre-blocking (DC),
•
without pre-blocking (DI) or
•
long-term (L)
Deactivation without Pre-Blocking:
The devices are manually blocked. (Long-term blocked devices remain blocked for a long period of time.) Existing connections are released immediately.
Deactivation with Pre-Blocking:
Existing connections are not released, the affected devices are blocked automatically after the release.
Long-Term Deactivation:
The devices are deactivated immediately and will not be administrated by DEP any longer. This is similar to ’Not Equipped’ (NEQ). The feature modem pooling is released.
Reference clock generator:
Parameter REFOFF controls deactivation of reference clock generator. If REFOFF = NO, H10 is displayed for a PEN to which a reference clock generator is assigned. This PEN won’t be deactivated.
If nothing is entered for parameter REFOFF, that means PROMPT, or Y is entered, there will be a check if the trunk represents the active reference clock generator. If the entered PEN leads to the only reference clock generator, H09 prompts, whether to deactivate this PEN or not.
If there are additional reference clock generators available, H08 will be prompted. If Y = deactivate, DEP will select another trunk from the reference clock table (AMO REFTA) as the active reference clock generator.
Voice compression:
If the circuit to be deactivated with OFFTYPE=DC is partner of a voice compression connection, the according VCM circuit will be deactivated automatically and the message H24 will be displayed.
Procedure Overview
Command Code
Parameter
DEACTIVATE-DSSU
[OFFTYPE=<param>]
,TYPE=STNO,STNO=<number>,[SVC=<param>];
|,TYPE=PEN,PEN1=<pen>,[PEN2=<pen>],[REFOFF=<param>];
|,TYPE=BCHAN,PEN1=<pen>,[BCHL=<number>];
Examples
1.
The line at port 1-1-6-1 is to be deactivated regardless of the current device status.
Input:
DEACTIVATE-DSSU:DI,PEN,1-1-6-1;
Output:
H01: SLMA 1-1-6-1 DEACTIVATED
2.
The FAX terminal equipment having DNs 252 to 256 and 205 are to be deactivated with pre- blocking.
Input:
DEACTIVATE-DSSU:DC,STNO,252&&256&205,FAX;
Possible Output:
H03: FAX 252 DEACTIVATED
F11: STNO 253 NOT CONFIGURATED
F12: STNO 254 PARAMETER SVC NOT ALLOWED
H04: FAX 256 PRE-BLOCKED
H05: FAX 205 DEACTIVATED FOR LONG PERIOD (NEQ STATE)
3.
Deactivate second B-channel for PEN 1-1-115-0
Input:
DEACTIVATE-DSSU:,BCHAN,1-1-115-0,2;
Output:
H05: BCHAN 1-1-115-0 DEACTIVATED FOR LONG PERIOD (NEQ STATE)
4.
Deactivate current reference clock at pen 1-1-37-0
Input:
DEACT-DSSU:,PEN,1-1-37-0;
Output:
H08: THE DEACTIVATE JOB AFFECTS THE CURRENT REFERENCE CLOCK GENERATOR"
PLEASE ANSWER PARAMETER REFOFF
Y . . . . DEACTIVATE CURRENT REFERENCE CLOCK GENERATOR
N . . . . DO NOT DEACTIVATE CURRENT REFERENCE CLOCK GENERATOR
*
Input:
Y;
Output:
H03: PEN 1-1-37-0 DEACTIVATED