83.5.1
Error Messages
F01:
PEN2 PRECEDES PEN1
F02:
LTG NUMBER <ltg> DOES NOT HAVE ADMISSIBLE VALUE, MAXIMUM VALUE: <max>
F03:
LTU NUMBER <ltu> DOES NOT HAVE ADMISSIBLE VALUE, MAXIMUM VALUE: <max>
F04:
SLOT <slot> DOES NOT HAVE ADMISSIBLE VALUE
F05:
CIRCUIT NUMBER <cir> DOES NOT HAVE ADMISSIBLE VALUE, MAXIMUM VALUE: <max>
F06:
LTG <ltg> NOT ASSIGNED (NEQ)
F07:
LTU <ltg>-<ltu> NOT ASSIGNED (NEQ)
F08:
MODULE <ltg>-<ltu>-<slot> NOT ASSIGNED (NEQ)
F09:
STNO XXXX / PEN <ltg>-<ltu>-<slot>-<cir> NOT ACTIVATED/SIGNED ON
F10:
PEN <ltg>-<ltu>-<slot> CIRCUIT NUMBER <cct> TOO LARGE
(The specified line number is greater than the largest line number of the module.)
F11:
xxxxx NOT CONFIGURED
(the station number is not in the station number plan)
F12:
STNO xxxxx PARAMETER SVC NOT ALLOWED
F13:
STNO xxxxx HAS NO <svc>-TERMINAL DEVICE
(A terminal matching parameter SVC is not configured for the specified DN.)
F14:
xxxx xxxxx WITHOUT PHYSICAL DEVICE
(There is no line for the specified DN; the station is a ’floating’ chip card user.)
F15:
xxxx xxxxx NOT ACTIVATED (ORDER ERROR)
(the activation job has been rejected by DC / CDC)
F16:
xxxx xxxxx NOT DEACTIVATED (ORDER ERROR)
(the deactivation job has been rejected by DC / CDC)
F17:
STATION CALL NUMBERS <stn1> AND <stn2> HAVE DIFFERENT LENGTHS
F18:
xxxx xxxxx CONSOLE DOES NOT BELONG TO ANY AC-GROUP
(the terminal connection of the attendant console must first be accepted in an AC group)
F19:
LAYER LOST AT PEN @@-@@-@@@-@@@ PLEASE WAIT FOR END OF SOFT LOCK OR LOCK THIS CIRCUIT HARD (DEACT-DSSU:DI,...;)
F20:
STNO <stno> SVC=DTE ONLY ALLOWED FOR CTE
F21:
STNO <stno> SINGLE FUNCTIONAL TERMINAL CANNOT BE SWITCHED
(The parameter SVC may not be specified for functional terminals)
F22:
ENTERED PEN IDENDIFIES NO S0-TRUNK-CHANNEL
F23:
STNO <stno> IS MSN-NUMBER AND THEREFORE SVC=MSN OR SVC=ALL HAS TO BE USED
F24:
STNO <stno> MSN-NUMBER NOT DEACTIVATED FOR CP (ORDER ERROR)
F25:
STNO <stno> IS NO MSN-NUMBER AND THEREFORE SVC=MSN IS NOT ALLOWED
F27:
DEVICE OF STNO <stno> IS NOT ALLOWED FOR SIGN OFF
F28:
MAIN NUMBER <stno> HAS ALREADY SIGNED ON NUMBERS
F29:
STNO <stno> IS ASSOCIATED WITH DATA DEVICE, SIGN OFF NOT POSSIBLE
F30:
STNO <stno> IS ALREADY SIGNOFF
F31:
STNO IS PRE-BLOCKED. REPEAT COMMAND LATER OR DEACTIVATE
IMMEDIATELY BY MEANS OF DEACT-DSSU:DI,STNO,<stno>;
F32:
ID CARD USER <stno> IS NOT SIGNED ON
F35:
STNO <stno> IS NOT SIGNED OFF
F36:
PEN IS ALREADY ASSIGNED
F37:
PEN IS AVAILABLE, BUT NOT SIGNED OFF, USE FIRST
CHANGE-BCSU:SIGNOFF,<ltg>,<ltu>,<ebt>,<cir>,<tsi>;
F38:
BOARD <bg> AND DEVICE <ger> DO NOT MATCH
F39:
PEN <ltg>-<ltu>-<slot>-<cct> <tsi> IS BUSY WITH CALL PROCESSING, THEREFORE SIGN ON NOT POSSIBLE
F40:
STNO IS IN AN UNDEFINED SIGN OFF STATE. SIGN OFF FIRST:
CHANGE-DSSU:SIGNOFF,<stno>;
F41:
STNO <stno> IS SIGNED OFF. THEREFORE IT CANNOT BE SWITCHED
F42:
SIGNON/SIGNOFF NOT POSSIBLE RIGHT NOW, REPEAT COMMAND LATER
F43:
STNO <stno> IS MSN-NUMBER, SIGN OFF NOT POSSIBLE
F44:
FOR STNO <stno> NO OPTISET-MASTER IS SIGNED ON
F45:
<block|unblock|reset> ONLY ALLOWED FOR BOARD DIUS7
F46:
B-CHANNEL <block|unblock|reset> NOT POSSIBLE, CIRCUIT STATUS MUST BE READY
F47:
RESET NOT POSSIBLE, ERROR WHEN READING THE BLOCKING DATA
F48:
BASESTATION <ltg>-<ltu>-<slot>-<cct> NOT LOADED, <loaderror>
F49:
PEN <ltg>-<ltu>-<slot> IDENTIFIES NO BASESTATION
F50:
EXEC ONLY ALLOWED FOR BOARD SLMC
F51:
B-CHANNEL <block|unblock|reset> NOT POSSIBLE, NO SUITABLE B-CHANNELS AVAILABLE
F52:
AN ACD-AGENT IS LOGGED ON STNO <stno>, SIGN OFF NOT POSSIBLE
F53:
PEN <ltg>-<ltu>-<slot> BOARD WITHOUT CIRCUITS
F54:
PEN <ltg>-<ltu>-<slot> NOT ACTIVATED
CANNOT ACTIVATE ATMPVC CIRCUITS WITH ONTYPE=AUL; ALL ATMSVC CIRCUITS OF THE STMA BOARD MUST BE LOCKED
F55:
PEN <ltg>-<ltu>-<slot> IS ONLY PRE-BLOCKED
STMA CIRCUITS CANNOT BE DEACTIVATED WITH ONTYPE=AUL IN THIS STATE (DEACTIVATE WITH OFFTYPE=DI PREVIOUSLY)
F56:
NO PEN FOUND
F57:
NO STATION NUMBER FOUND
F58:
STNO <stno> IS USING ONE OF ITS LINE APPEARANCES, THEREFORE SIGN OFF IS NOT POSSIBLE
F59:
STNO <stno> SIGN OFF IS NOT POSSIBLE, BECAUSE IT’S PRIMARY LINE IS STILL IN USE BY STNO <stno>
F60:
CANNOT LOAD ATMPVC CIRCUITS; ALL ATMSVC CIRCUITS OF THE STMA BOARD MUST BE LOCKED
F61:
<stno> THE MAXIMUM PLANNED NUMBER OF STATIONS HAS BEEN REACHED.
THE NUMBER OF STATIONS ALLOWED CAN BE INCREASED WITH AMO DIMSU
F62:
<stno> INSUFFICIENT LINE MEMORY SPACE FOR VIRTUAL LINES
F63:
<stno> SIGN ON IS NOT POSSIBLE, BECAUSE AN OPTISET WITH AN API CAN
ONLY BE SIGNED ON TO A PEN WITH A SIGNED OFF TSI FOR AN OPTISET AND A SIGNED OFF TSI FOR AN API.
F64:
SIGNON/SIGNOFF IS NOT ALLOWED FOR STNO ^tlnnu^ (AMO SDAT)
F65:
PEN @@-@@-@@@-@@@ BCHAN @@ NOT ACTIVATED (ORDER ERROR)
F66:
PEN @@-@@-@@@-@@@ BCHAN @@ NOT DEACTIVATED (ORDER ERROR)
F67:
PEN @@-@@-@@@-@@@ NOT ACTIVATED (SIGNALLING CIRCUIT)
F68:
PEN @@-@@-@@@-@@@ NOT DEACTIVATED (SIGNALLING CIRCUIT)
F69:
ACTIVATION OF THE CIRCUIT WITH ONTYPE=AUL HAS NOT BEEN PROCESSED,BECAUSE CORRESPONDING WAML BOARD IS PRE-BLOCKED. BOARD MUST BE SWITCHED ON WITH THE FOLLOWING COMMAND FIRST: ACTIVATE-BSSU:,@@,@@,@@@;