114.3.3
CHANGE-HISTA
This verb is used to change the configuration of the HW-Error statistic.
Procedure Overview
Command Code
Parameter
CHANGE-HISTA
ENTRY=STALARM,[STATUS=<param>] ;
ENTRY=NEW/OLD,[NUM=<number>],[THRESH=<number>],
[DECTH=<number>],[DECTM=<number>],
[ALARM=<param>];
Parameter description
ENTRY
IS A branch parameter
ENTRY=STALARM
Statistic - Alarming
STATUS
Activates/deactivates the alarm signalization
ENTRY=NEW
A new entry will be added into the configuration table
NUM
The number of an error message
possible values (2000 to 8999)
THRESH
The threshold value
possible values (1 to 65535)
DECTH
The time interval to decrement the error counter (max. 100h)
possible values (1 minute to 100 hours)
DECTM
The time interval to decrement the error counter (max. 60min.)
ALARM
Alarming in case to exceed the threshold
ENTRY=OLD
Change of an existing configuration entry
NUM
The number of an error message
possible values (2000 to 8999)
THRESH
The threshold value
possible values (1 to 65535)
DECTH
The time interval to decrement the error counter (max. 100h)
possible values (1 minute to 100 hours)
DECTM
The time interval to decrement the error counter (max. 60min.)
ALARM
Alarming in case to exceed the threshold