114.4
Parameter Description
ALARMTYP
Alarm type
Type of Input
:
Single value, mandatory (for CONTEXT = ALARM)
Possible Values
:
CENTRAL
SWUPERI
LOGSPEC
LOGDIR
LOGPERS
SMPERI
ANS
Answer
After every screen page (15 lines) a new "Continue" prompt is issued.
Type of Input
:
Single value, optional
Possible Values
:
Y = output next page
N = stop output
C = continue, i.e. output all further error messages.
CC
Call code
Type of Input
:
Single value, mandatory (for CONTEXT = CC)
Possible Values
:
0001 to FFFE
CCT
Circuit number
Type of Input
Single value, optional (for CONTEXT = PEN)
Possible Values
:
0 to 9999
CENTRAL
Alarm type : CENTRAL
Type of Input
:
Single value, mandatory (for ALARMTYP = CENTRAL)
Possible Values
:
CENTRAL_00 ... LTG_RESTARTS
CENTRAL_01 ... LTG_FAILURE
CENTRAL_02 ... LTU_FAILURE
CENTRAL_03 ... PHONEMAIL_ALARM
CENTRAL_04 ... LTU_HW_STATUS_BUS
CENTRAL_05 ... CC_RESTARTS
CENTRAL_06 ... CC_STBY_FAILURE
CENTRAL_07 ... LTUR_RESTARTS
CENTRAL_08 ... RMS_FAILURE
CENTRAL_09 ... CHARGE_COMPUTER
CENTRAL_10 ... IS_RESTARTS
CENTRAL_11 ... CENTRAL_ALARM_11
CENTRAL_12 ... CENTRAL_ALARM_12
CENTRAL_13 ... SM_RESTARTS
CENTRAL_14 ... CENTRAL_ALARM_14
CENTRAL_15 ... EXTERNAL_SERVER
CENTRAL_16 ... LTG_CENTRAL_CONTROL
CENTRAL_17 ... CC_CENTRAL_CONTROL
CENTRAL_18 ... SWITCHING_NETWORK
CENTRAL_19 ... CLOCKING_SYSTEM
CENTRAL_20 ... SIGNAL_UNIT
CENTRAL_21 ... IS_CENTRAL_CONTROL
CENTRAL_22 ... SM_CENTRAL_CONTROL
CENTRAL_23 ... SW_ERRORS
CENTRAL_24 ... SYSTEM_MESSAGE
CENTRAL_25 ... POWER_SUPPLY
CENTRAL_26 ... SM_FAILURE
CENTRAL_27 ... XENIX_ALARM
CENTRAL_28 ... SYSTEM_TIME_FAILURE
CENTRAL_29 ... MAINTENANCE_NOTE
CENTRAL_30 ... SWITCHING_UNIT_FAILURE
CENTRAL_31 ... CENTRAL_ALARM_31
CENTRAL_32 ACCESS POINT FAILURE
CENTRAL_33 BAD IP CONNECTIVITY
CENTRAL_34 LW-SW VERSION CONFLICT
CENTRAL_35 ... CENTRAL_ALARM_35
CENTRAL_36 ... CENTRAL_ALARM_36
CENTRAL_37 ... CENTRAL_ALARM_37
CENTRAL_38 ... CENTRAL_ALARM_38
CENTRAL_39 ... CENTRAL_ALARM_39
CENTRAL_40 ... CENTRAL_ALARM_40
CENTRAL_41 ... CENTRAL_ALARM_41
CENTRAL_42 ... CENTRAL_ALARM_42
CENTRAL_43 ... CENTRAL_ALARM_43
CENTRAL_44.. CENTRAL_ALARM_44
CENTRAL_45 ... CENTRAL_ALARM_45
CENTRAL_46 ... CENTRAL_ALARM_46
CENTRAL_47 ... CENTRAL_ALARM_47
CENTRAL_48 ... CENTRAL_ALARM_48
CENTRAL_49 ... CENTRAL_ALARM_49
CENTRAL_50 ... CENTRAL_ALARM_50
CENTRAL_51 ... CENTRAL_ALARM_51
CENTRAL_52... CENTRAL_ALARM_52
CENTRAL_53 ... CENTRAL_ALARM_53
CENTRAL_54 ... CENTRAL_ALARM_54
CENTRAL_55 ... CENTRAL_ALARM_55
CENTRAL_56 ... CENTRAL_ALARM_56
CENTRAL_57 ... CENTRAL_ALARM_57
CENTRAL_58 ... CENTRAL_ALARM_58
CENTRAL_59 ... CENTRAL_ALARM_59
CENTRAL_60 ... CENTRAL_ALARM_60
CENTRAL_61 ... CENTRAL_ALARM_61
CENTRAL_62 ... CENTRAL_ALARM_62
CENTRAL_63 ... CENTRAL_ALARM_63
CONTEXT
Search criterion
Type of Input
:
Single value, optional
Possible Values
:
MID
ALARM
PEN
STNO
PRI
FUNCT
EC
CC
UA
EC
Exception code
Type of Input
:
Single value, mandatory (for CONTEXT = EC)
Possible Values
:
0001 to FFFE
ETIME
End time for search operation
Type of Input
:
Single value, optional
Possible Values
:
Default value
:
System time
FUNCT
Function complex
Type of Input
:
Single value, mandatory (for CONTEXT = FUNCT)
Possible Values
:
SWUPER ....... SWU periphery
SWU_CENTRAL .. Central SWU modules
SW_ERROR ..... SW errors
SYSTEM ....... SYSTEM errors
SM_PER ....... SM periphery
SM_CENTRAL ... Central SM modules
LOGDIR
Alarm type : LOGDIR
Type of Input
:
Single value, mandatory (for ALARMTYP = LOGDIR)
Possible Values
:
8 to 519
LOGPERS
Alarm type : LOGPERS
Type of Input
:
Single value, mandatory (for ALARMTYP = LOGPERS)
Possible Values
:
520 to 583
LOGSPEC
Alarm type : SWUSPEC
Type of Input
:
Single value, mandatory (for ALARMTYP = SWUSPEC)
Possible Values
:
SWU_LOG_00 ... NO_DEVICE_CLASS
SWU_LOG_01 ... INWARD_DIALING
SWU_LOG_02 ... OUTWARD_DIALING
SWU_LOG_03 ... SWU_LOG_03
SWU_LOG_04 ... DIUC_ITALY
SWU_LOG_05 ... PHONEMAIL_ACCESS
SWU_LOG_06 ... SWU_LOG_06
SWU_LOG_07 ... SWU_LOG_07
LTG
LTG number
Type of Input
:
Single value, mandatory (for CONTEXT = PEN)
Possible Values
:
0 to 9999
LTU
LTU number
Type of Input
:
Single value, optional (for CONTEXT = PEN)
Possible Values
:
0 to 9999
MID
Type of fault report (error/alarm message)
Type of Input
:
Single value, mandatory (for CONTEXT = MID)
Possible Values
:
AL
EM
NUM
Number of fault report (error/alarm message)
Type of Input
:
Single value, mandatory (for CONTEXT = MID)
Possible Values
:
1000 to 9999
PRI
Priority
Type of Input
:
Single value, mandatory (for CONTEXT = PRI)
Possible Values
:
M1 priority M1
M2 priority M2
M3 priority M3
M4 priority M4
M5 priority M5
M6 priority M6
M7 priority M7
M8 priority M8
E1 priority E1
E2 priority E2
E3 priority E3
E4 priority E4
E5 priority E5
E6 priority E6
E7 priority E7
E8 priority E8
RTYPE
Function type
Type of Input
:
Single value, mandatory
Possible Values
:
SEARCH, SEARCHB .. search function
MIRROR .. alarm mirror
SLOT
SLOT number
Type of Input
:
Single value, optional (for CONTEXT = PEN)
Possible Values
:
0 to 121
A suitable module must be configured for the slot addressed by PEN (AMO BCSU).
The possible Slot values depend on the systems architecture and can be found in the BCSU AMO description.
SMPERI
Alarm type : SMPERI
Type of Input
:
Single value, mandatory (for ALARMTYP = SMPERI)
Possible Values
:
SM_PERI_00 ... SERVICE_TELETYP
SM_PERI_01 ... SERVICE_UTC
SM_PERI_02 ... SERVICE_TTX
SM_PERI_03 ... SERVICE_FAX
SM_PERI_03 ... SERVICE_FAX
SM_PERI_04 ... SERVICE_VOICE
SM_PERI_05 ... SERVICE_XENIX
SM_PERI_06 ... SERVICE_BSC
SM_PERI_07 ... SERVICE_ISO
SM_PERI_08 ... SERVICE_IBM
SM_PERI_09 ... SM_PERI_09
SM_PERI_10 ... SM_PERI_10
SM_PERI_11 ... SM_PERI_11
SM_PERI_12 ... SM_PERI_12
SM_PERI_13 ... SM_PERI_13
SM_PERI_14 ... IS_FLASH_MEMORY
SM_PERI_15 ... SM_FLASH_MEMORY
SM_PERI_16 ... IS_DAT_RECORDER
SM_PERI_17 ... SM_DAT_RECORDER
SM_PERI_18 ... IS_HARD_DISK
SM_PERI_19 ... IS_CARTRIDGE
SM_PERI_20 ... IS_TAPE
SM_PERI_21 ... SM_HARD_DISK
SM_PERI_22 ... SM_PERI_22
SM_PERI_23 ... SM_PERI_23
STIME
Start time for search operation
Type of Input
:
Single value, optional
Possible Values
:
Default value
:
System time - 2 hours
STNO
Station number
Type of Input
:
Single value, mandatory (for CONTEXT = STNO)
Possible Values
:
0 to 999999
SVC
Type of service
Type of Input
:
Single value, optional (for CONTEXT = STNO)
Possible Values
:
VCE
VTX
TTX
FAX
DTE
SWUPERI
Alarm type : SWUPERI
Type of Input
:
Single value, mandatory (for ALARMTYP = SWUPERI)
Possible Values
:
SWU_PERI_00 .. C-O TRUNK/EXCH_LINE
SWU_PERI_01 .. TIE_LINE
SWU_PERI_02 .. MULTIPLE_DEVICES
SWU_PERI_03 .. ANALOG_VOICE_DEVICES
SWU_PERI_04 .. DIGITAL_VOICE_DEVICES
SWU_PERI_05 .. ATTENDANT_CONSOLE
SWU_PERI_06 .. C-O/EXCHANGE_DATA_LINE
SWU_PERI_07 .. TIE_DATA_LINE
SWU_PERI_08 .. BASE_STATION
SWU_PERI_09 .. LOGICAL_DEVICES
SWU_PERI_10 .. TFS_LINE
SWU_PERI_11 .. VMS_LINE
SWU_PERI_12 .. APSE
SWU_PERI_13 .. OTHER_DEVICES
SWU_PERI_14 .. DATA_DEVICES
SWU_PERI_15 .. SWU_PERI_15
SWU_PERI_16 .. SWU_PERI_16
SWU_PERI_17 .. SWU_PERI_17
SWU_PERI_18 .. SWU_PERI_18
SWU_PERI_19 .. SWU_PERI_19
SWU_PERI_20 .. SWU_PERI_20
SWU_PERI_21 .. SWU_PERI_21
SWU_PERI_22 .. SWU_PERI_22
SWU_PERI_23 .. SWU_PERI_23
SWU_PERI_24 .. SWU_PERI_24
SWU_PERI_25 .. SWU_PERI_25
SWU_PERI_26 .. SWU_PERI_26
SWU_PERI_27 .. SWU_PERI_27
SWU_PERI_28 .. SWU_PERI_28
SWU_PERI_39 .. SWU_PERI_29
SWU_PERI_30 .. SWU_PERI_30
SWU_PERI_31 .. SWU_PERI_31
UA
Selector for SW address
Type of Input
:
Single value, mandatory (for CONTEXT = UA)