130.3.1
ADD-LCSM
Restriction:
There don't exist ASYNCH - or V24 - Lines in a Hipath 4000 V2.0 .
Procedure Overview
Command Code
Parameter
ADD-LCSM
[UNIT=<param>]
,MLNTYPE=ASYNC,TYPENO=<number>,BAUD=<number>
,LEN=<number>,STOPLEN=<param>,TRNSCLK=<param>
,RCLK=<param>;
|,MLNTYPE=V24,TYPENO=<number>,NORM=<param>
,OPTYPE=<param>,SPEED=<param>,CLK=<param>
,TIME=<number>,LNTYPE=<param>;
Example
Creation of line data for administration and data module 1 for an asynchronous line.
Input:
ADD-LCSM:A1,ASYNC,1,4800,7,SL1.5,INT,EXT;
Note
The module for the physical line must be present.
Note
If the length of stop has value SL1.5 the value SL1.5 is mapped internally to the value SL1.