145.4
Parameter Description
ACKTIM
Acknowledgement timer: timer specifies the period between transmission of a command frame and the expected receipt of the response or acknowledgement. Value is specified in tenth of seconds.
Type of Input
single value, 7. parameter of a min-1-group
Possible Values
10-50
Default Value
10
APCPN
Analogue pstn call priority number
Type of Input
single value, 3. parameter of a min-1-group
Possible Values
numeric, 0-16
Default Value
14
AROB
Automatic redirection on busy
Type of Input
single value, 5. parameter of a min-1-group
Possible Values
N
Y
Default Value
ATCPN
Analogue trunk call priority number
Type of Input
single value, 1. parameter of a min-1-group
Possible Values
numeric, 0-16
Default Value
12
BCHCONF
DPNSS B Chanel X/Y Configuration
Type of Input
:
0 to 30 single values, concatenated with & or &&, optional
Possible Values
:
numeric, 0-30
Default Value
:
BCHNEG
B Channel Negotiation
Type of Input
:
single value, optional
Possible Values
:
N
Y
no
yes
Default Value
:
Y
BLNO
Parameter block number
Type of Input
:
Single value, mandatory (CHANGE)
Single value or range, optional (DISPLAY)
Possible Values
:
0 - 200
(TMD circuit type)
0 - 25
(DIUS2 circuit type)
0-255
(CDG, DIUS2 circuit type)
0-49
(CDG circuit type)
0-78
(NWWTK networking wtk set type)
1-200
(TMD circuit type)
1-6
(DIUC modul type)
BLNONEW
New parameter block number
Type of Input
single value, optional
Possible Values
numeric, 0-49
COPY, TYPE=CDG
numeric, 0-9
COPY, TYPE=DIUS2
numeric, 1-200
COPY, TYPE=TMD
BLNOOLD
Old parameter block number
Type of Input
single value, mandatory
Possible Values
numeric, 0-255
TYPE=CDG
numeric, 0-200
TYPE=TMD
C3CONF
3-party conference hold allowed from conference master.
Type of Input
:
Single value, 21. parameter of a min-1-group, optional
Possible Values
:
Y
N
Yes
No
CABLETYP
type of cable for tmd span
Type of Input
single value, 2. parameter of a min-1-group
Possible Values
numeric, 1-7
Default Value
3
CBG
Call barring group (Realitis DX)
Type of Input
1 to 8 single values, concatenated with &, optional
Possible Values
numeric, 0-127
CDG
CDG is connected to DIUS2 (conversion from CORNET to DPNSS1 or DASS2, used in Italy and the UK, for example).
Type of Input
:
Single value, optional
Possible Values
:
Y
N
Yes
No
Default Value
:
N
CDGCF
CDG Transit Working on Call Forward
Type of Input
:
single value, optional
Possible Values
:
Y
N
YES
NO
Default Value
:
Y
CDGTYPE
Type of CDG
Type of Input:
single value, mandatory
Possible Values
:
CONF
TIMER
Configuration parameter
Timer and reserve parameter
MAPPING
Mapping tables HICOM <-> Realitis DX
CONF2
Configuration - extension for CDG 6.0
CNTRNR
(CouNT Receiver Not Ready) The number of status queries sent to the partner in regard to "receiver not ready" is defined.
Type of Input
:
Single value, optional
Possible Values
:
0 - 255
Default Value
:
255
CONACK
Connect ack sent by protocol handler
Type of Input
:
Single value, 22. parameter of a min-1-group, optional
Possible Values
:
N
:
Y
:
CONVBN
Conversion back-notify from cornet-n
Type of Input
single value, 19. parameter of a min-1-group
Possible Values
N
no
Y
yes
:
COPA
Adaptation of diuc to various pcm30 central offices
Type of Input
single value, 2. parameter of a min-1-group
Possible Values
CO1G
digital access to tdm central office 1 g
CO2G
dig. access to tdm central office 2g or tne 2g
COIT
identifier for l1 error handling
TNE1A
dig.access to remote equipment 1 g (ver.tne 1a)
TNE1B
dig.access to remote equipment 1g (ver.tne 1b)
:
ZERO
basic initialization, no parameters set
:
COPTYPE
Copper line type
Type of Input
single value, 10. parameter of a min-1-group
Possible Values
COAX75
coax 75 Ohm
STP120
shielded twisted pair 120 Ohm
COS
Class-of-service marks / features
The values CDRAC, CDRC, and CDRS cannot be linked with NCDR.
The values EXTEND and PU cannot be linked.
The values OVR and KN cannot be linked.
Type of Input
:
maximum of 5 linked single values, optional
Possible Values
:
CDRAC
Call data registration on attendant console
CDRC
Central call data registration
CDRS
Call data registration at station
NCDR
No call data registration
EXTEND
Extend
PU
Pickup
OVR
Override
KN
Call waiting
Default Value
:
NCDR, PU, KN
COS1
EMS/System class-of-service assignment (EMS COS:LOC)
COS2
EMS/System class-of-service assignment (EMS COS:AREA)
COS3
EMS/System class-of-service assignment (EMS COS:NAT)
COS4
EMS/System class-of-service assignment (EMS COS:CONT)
COS5
EMS/System class-of-service assignment (EMS COS:INT)
for system as a main PABX or satellite PABX TA and RTA are not valid values here, since they have the identical meaning in the system and EMS, and can therefore be passed through.
Note
:
Overall COS ’CO’ supplements loadware;
RTA for outward restriction is always set as per the basic DB initialization.
Type of Input
:
max. 6 linked single values, optional
Possible Values
:
RTA1:
RESTRICTED TRUNK ACCESS 1
RTA2:
RESTRICTED TRUNK ACCESS 2
RTA3:
RESTRICTED TRUNK ACCESS 3
RTA4:
RESTRICTED TRUNK ACCESS 4
RTA5:
RESTRICTED TRUNK ACCESS 5
RTA6:
RESTRICTED TRUNK ACCESS 6
Default Value
:
RTA1
CRC4C
CRC4 CorNet NQ
Type of Input
:
Single value, optional
Possible Values
:
Y
N NO
Default Value
:
N
CRC4REP
Layer-2 CRC4-Reporting
Type of Input
:
Single value, optional
Possible Values
:
Y, N
Default Value
:
N
CRIDC
Carrier Idenfication Code
Type of Input
:
Single value, optional
Possible Values
:
0000-9999s
Default Value
:
Note
:
mandatory when block is used for CVN
CTYPE
Evaluate digit pre-setting for corresponding existing connection type (incoming) (see parameters DGTPRMS, DGTPRMST, DGTPRMSI) The value N cannot be linked with any other value.
Type of Input
:
Maximum of 3 linked single values, optional
Possible Values
:
HOME, CO, TOLL, N
Default Value
:
N
DASSCPN
DASS call priority number
Type of Input
:
single value, 4. parameter of a min-1-group, optional
Possible Values
:
numeric, 0-16
Default Value
:
13
DASSOPN
DASS operator number
Type of Input
:
single value, optional
Possible Values
:
0-9,*,#,A-D, up to 22 characters
DCHAN1
Definition of timeslot for first data channel
Type of Input
:
Single value, optional
Possible Values
:
0 - 31 (0= no data channel)
Default Value
:
16
DCHAN2
ATTENTION: This function has
not
been implemented!
Definition of timeslot for a second data channel If DCHAN2>0, DCHAN1 may not be 0. Furthermore, DCHAN1 and DCHAN2 must have different values, except when both parameters have the value 0. The specified DCHAN2 number may not be configured as a device. A second D-channel is useful, for example, if a system user leases from the post office 10 B-channels of an S2-path as nailed connections via local exchanges to a certain remote system and, due to extensive signaling, defines one of these 10 B-channels as a ’private channel’. In both systems, the additional D-channel must be made known using loadware parameters and COT.
Type of Input
:
Single value, optional
Possible Values
:
0
(0= no second data channel)
Default Value
:
0
Note
:
DCHAN2 may not be 0 if the parameter block is allocated to a circuit which has been assigned a class of trunk (AMO TDCSU, parameter COTNO) in which the circuit parameter PRDC (private D channel; AMO COT, parameter PAR) is specified.
The speed dialing codes to be pre-set (DGTPR and DGTPRC) are only evaluated if the correct value for parameter SPDCDSS (SPD for DGTPR, SPDC for DGTPRC) has been specified.
DEFID
ROP, default call identity length used in CorNet-NQ
Type of Input:
single value, optional
Possible Values
B001
1 digit
B010
2 digits
B011
3 digits
B100
4 digits
Default Value
:
B010
DEFPASSW
Default password for DPNSS protocol
Type of Input
single value, optional
Possible Values
numeric, up to 6 characters
DEV
Kind of device on trunk
Type of Input
single value, optional (CHANGE)
single value, optional (ADD/DISPLAY)
Possible Values
see parameter values DEV in AMOs TDSCU, TACSU, TSCSU
This parameter indicates for what kind of device the LWPAR block is suitable. All values are accepted, no check is performed. The user is asked to use the right device types.
DGTPR
Speed dialing code to be pre-set for seizure from satellite PABX (valid for SPD 1-15)
If only one speed dialing code has been assigned in the system, and if both speed dialing codes (DGTPR,DGTPRC) are to be evaluated in accordance with parameter SPDCDSS, DGTPR must be equal to DGTPRC and lead to DAR ’SPDC1’ in the DPLN. If two speed dialing codes have been assigned, DGTPR must lead to DAR ’SPDC2’ in the DPLN.
Type of Input
:
Single value (up to 6 digits), optional
Possible Values
:
0 - 9, *, #
Default Value
:
none
DGTPRC
Speed dialing code (central) to be pre-set for seizure from satellite PABX
If only one speed dialing code has been assigned in the system, and if both speed dialing codes (DGTPR,DGTPRC) are to be evaluated in accordance with parameter SPDCDSS, DGTPRC must be equal to DGTPR.
DGTPRC must lead to DAR ’SPDC1’ in the DPLN.
Type of Input
:
Single value (up to 6 digits), optional
Possible Values
:
0 - 9, *, #
Default Value
:
none
The following digit pre-setting parameters DGTPRMS, DGTPRMSI and DGTPRMST are evaluated only if the corresponding parameter value (CO, HOME, TOLL) of the parameter CTYPE is set. The entry ’*’ signifies that no digit pre-setting should be assigned. Pre-set digits are set according to line signal processing of the recorded dial information and handled by call processing as dialed digits.
DGTPRMS
Digit pre-setting after incoming seizure for connection type CO
DGTPRMSI
Digit pre-setting after incoming seizure for connection type HOME or RF_CO
DGTPRMST
Digit pre-setting digit after incoming seizure for connection type TOLL
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 or *
Default Value
:
*
DLVTIM
Data link verification timer: timer specifies maximum period of link inactivity (no frames exchanged). Value is specified in tenth of seconds.
Type of Input
single value, 8. parameter of a min-1-group
Possible Values
50-600
Default Value
30
DXTG
Realitis DX trunk group Number(s)
Type of Input
1 to 8 single values, concatenated with &, optional
Possible Values
numeric, 0-255
DXTGPOS
Position of given DXTG number(s) in TTB table
Type of Input
1 to 8 single values, concatenated with &, optional
Possible Values
numeric, 0-31
EDP
Pause between EOD preliminary pulse and recognized dial end
Type of Input
:
Single value, optional
Possible Values
:
100 - 450 ms
Default Value
:
100 ms
EQVIRC
DPNSS Equipped Virtual Channels
Type of Input
:
0 to 30 single values, concatenated with & or &&, optional
Possible Values
:
numeric, 0-30
Default Value
:
FCBAB
Parameterization of frame code and answering byte
Type of Input
:
Single value, optional
Possible Values
:
two-digit, hexadecimal
Default Value
:
DFH
The hex value to be entered is based on the following context:
In the byte to be parameterized, the answer byte is parameterized in bits 1 and 4 through 8 by counting down from the bit with the highest value. Bit 2, which is free, is used to store information on the frame code. This bit position evaluates the loadware in regard to "bit 1" for the frame code.
The hex value to be entered is thus derived from the bit pattern for the parameterization of the answer byte (AB) and the frame code(FC).
Byte to be parameterized:
(bit with lowest value on the right!)
bits 1 and 4 through 8 of the AB are entered.
Bit 2 : here bit 1 of the FC is entered.
Bit 3 is free.
FIXEDTEI
Option to specify a value other than 0 for "FIXED TEI" for point-to-point connections
Type of Input
:
Single value, optional
Possible Values
:
0 - 63
Default Value
:
0
FORMAT
Format of output
Type of Input:
single value, optional
Possible Values
L long output format
S short output format
Default Value
:
L
ICPN
Internal call priority number
Type of Input
:
Single value, 2. parameter of a min-1-group, optional
Possible Values
:
numeric, 0-16
Default Value
:
11
INFO
Service Informations
Type of Input:
single value, optional
PossibleValues
:
text, up to 50 characters
INFOPAT
Service info text pattern
Type of Input:
single value, optional
Possible Values
:
text, up to 50 characters
IPLDS
The default intrude level assumed by CDG for DPNSS party
Type of Input
single value, 21. parameter of a min-1-group, optional
Possible Values
A
intrusion allowed
NA
intrusion not allowed
ITR
HICOM internal trafic restrictions number
Type of Input
single value, optional
Possible Values
numeric, 0-15
LCOS
LCR Class of service (Hicom)
Type of Input
1 to 8 single values, concatenated with &, optional
Possible Values
numeric, 1-32
LCOSMAP
Enable mapping of LCOS and TRG values?
Type of Input
single value, optional
Possible Values
YES
No
LNTYPE
Line type
Type of Input
:
max.two linked single values, optional
The values COPPER AND OWG may be set only alternatively
Possible Values
:
COPPER
4-wire copper connection
OWG
Optical wave guide
AERIAL
aerial connection
Default Value
:
COPPER
LSCF
loadware saved compressed in flash
Type of Input
:
single value, optional
Possible Values
:
Y
N
YES
NO
Default Value
:
N
N
LWPARREF
output lwpar reference information
Type of Input
single value, optional
Possible Values
Y
N
MASTER
Meaning of Layer 2 message (e.g. DIUS2)
(Command / Response : Master, Slave)
Type of Input
:
Single value, optional
Possible Values
:
Y
Master
N
Slave
Default Value
:
N
MAXTMS
DPNSS Maximum Transit Message Size
Type of Input
:
single value, optional
Possible Values
:
numeric, 0-2048
Default Value
:
500
MFCB
Parameterization of multiple frame code
Type of Input
:
Single value, optional
Possible Values
:
two-digit, hexadecimal
Default Value
:
FEH
Note
:
Value H’0B must be specified for use in France.
NSFIV
NSF IE Code to Access VPN Calling service
Type of Input
:
Single value, optional
Possible Values
:
0-31
Default Value
:
1
NSFTSC
NSF IE Code to Activate CA-TSC
Type of Input
:
Single value, optional
Possible Values
:
0-31
Default Value
:
9
NSIMSGS
msg size nsi to non nsi switchover
Type of Input
:
single value, optional
Possible Values
:
numeric, 100-2048
Default Value
150
NSIOUT
Insert nsi dpnss outgoing
Type of Input
:
single value, optional
Possible Values
:
Y
N
YES
NO
Default Value
Y
NSITR
NSI CORNET-NQ Transit
Type of Input
:
single value, optional
Possible Values
:
Y
N
YES
NO
Default Value
Y
OCTMAX
Maximum number of octets in an information field. Value is specified in number of octets.
Type of Input
single value, 9. parameter of a min-1-group
Possible Values
3-260
Default Value
260
OESDISTH
Out of frame errored seconds disqualification threshold. Number of OES before disqualification of the reference clock occurs. Value is specified in seconds.
Type of Input
single value, 3. parameter of a min-1-group
Possible Values
1 - 65535
Default Value
30
OESREQTH
Out of frame errored seconds requalification threshold. Maximum number of OES which may occur during the requalification interval before requalification of the reference clock source will occur. Value is specified in seconds
Type of Input
single value, 4. parameter of a min-1-group
Possible Values
1 - 65535
Default Value
4
OPMODE
Board operation mode
Type of input
0 to 6 single values, concatenated with &,
Possible Values
BDETON
bipolar violation detection on
BISUB8ON
bipolar 8 substitution on
FRAMEESF
extended framing
NETUSER
user will emulate network end of the digital span
TABSON
digital link switch enable tabs
TIMLOOP
loopback state - TMD frame timing driven by loop
PATM
Pause time for DTMF dialing (dual tone multifrequency signaling)
Type of Input
:
Single value, optional
Possible Values
:
20 - 255 ms
Default Value
:
40 ms
PATTERN
Idle bit pattern for the B-channels on the route
Type of Input
.
Single value, optional
Possible Values
:
two-digit, hexadecimal
Default Value
:
D5H
PERMACT
PCM link is permanently active
Type of Input
:
Single value, 11. parameter of a min-1-group, optional
Possible Values
:
Y, N
Default Value
:
Y
PRIMDXTG
Primary Realitis DX trunk group number
Type of Input
single value, optional
Possible Values
numeric, 0-254
PROT
Protocol - relevant for CORNET-N protocol only
Type of Input
:
single value, optional
Possible Values
:
DASS
DPNSS
dass/cornet-n
dpnss/cornet-n
Default Value
:
DPNSSN
PUTM
Pulse time for DTMF dialing (dual tone multifrequency signaling)
Type of Input
:
Single value, optional
Possible Values
:
20 - 100 ms
Default Value
:
60 ms
QUAL
Activate CRC4 procedures on the DIUC (e.g. use in Denmark).
The two parameters QUAL1 and QUAL2 which are only evaluated if QUAL is set to ON are also included in these procedures.
Type of Input
:
Single value, optional
Possible Values
:
ON
Ascertain transmission quality
OFF
Do not ascertain transmission quality
Default Value
ON
QUAL1
Time (sec.) for transmission quality worse than 10
If an error occurs during the specified time, the path is taken out of service!
This parameter is only in effect if parameter QUAL=ON.
Type of Input
:
Single value, optional
Possible Values
:
0 - 255 sec.
Default Value
:
10 sec.
QUAL2
Time (min.) for transmission quality worse than 10
If an error occurs during the specified time, the route is taken out of service!
This parameter is only in effect if parameter QUAL=ON.
Type of Input
:
Single value, optional
Possible Values
:
0 - 255 min.
Default Value
:
10 min.
RES3
Reserve 3 - may be used for test purpose
Type of Input
:
single value, optional
Possible Values
:
0 - 65535
Default Value
:
0
RES4
Reserve 4 - may be used for test purpose
Type of Input
:
single value, optional
Possible Values
:
0 - 65535
Default Value
:
0
RES5
Reserve 5 - may be used for test purpose
Type of Input
:
single value, optional
Possible Values
:
0 - 65535
Default Value
:
0
RESTALL
restart all laps at startup
Type of Input
:
single value, optional
Possible Values
:
N
Y
NO
YES
Default Value
:
Y
RESTLNK
restart link at startup
Type of Input
:
single value, optional
Possible Values
:
N
Y
NO
YES
Default Value
:
Y
RETMAX
Maximum number of retransmissions. Maximum number of retransmissions before an error is re-ported.
Type of Input
single value, 10. parameter of a min-1-group
Possible Values
1-10
Default Value
3
RRG
Route restriction group (realitis DX)
Type of Input
1 to 8 single values, concatenated with &, optional
Possible Values
numeric, 0-127
SADRTM
DASS-CorNet subaddress translation methode
Type of Input
:
single value, optional
Possible Values
:
NSAP
USER
network service access point
user specified
Default Value
:
NSAP
SCCONF
Station controlled conference
Type of Input
:
single value, 6. parameter of a min-1-group
Possible Values
:
N
Y
no
yes
Default Value
:
SESDISTH
severely errored seconds disqualification threshold. Number of sequential SES before disqualification of the reference clock occurs. Value is specified in tenth of seconds
Type of Input
single value, 5. parameter of a min-1-group
Possible Values
numeric, 1-65535
Default Value
10
SESREQTH
Severely errored seconds requalification threshold. Number of sequential seconds with SES absent before requalification of the reference clock occurs. Value is specified in tenth of seconds
Type of Input
single value, 6. parameter of a min-1-group
Possible Values
numeric, 1-65535
Default Value
10
SMD
Layer 1 configuration (subscriber module digital)
If circuits are allocated with the device type S2COD (AMO TDCSU), SMD must be declared as N (no). If Y (yes) is entered, then all allocated circuits entered in the reference clock table (AMO REFTA) must have a priority of ’0’.
Type of Input
:
Single value, optional
Possible Values
:
Y
SMD
N
TMD
Default Value
:
N
SOURCE
Location of LWPAR block; indicates where the block has to be copied from
Type of Input
single value, optional
Possible Values
HD
Harddisk
DB
Database
SPD1
Assignment of the 16 speed dialing groups from the system to the
SPD2
6 speed dialing groups for WTK (AC voice frequency signaling)
SPD3
Type of Input
:
Single value, optional
SPD4
Possible Values
:
0
Assignment to central SPD
SPD5
1 - 15
Assignment to certain SPD groups
SPD6
Default Value
:
1
SPDC1
Central 1 automatic dialer
Type of Input
single value, optional
Possible Values
numeric, 0-16
SPDCDSS
Parameter indicat. that the spdc from the ss is not transm.
Type of Input
0 to 2 single values, concatenated with &, 21. parameter of a min-1-group
Possible Values
NO
no
SPD
speed dialing
SPDC
speed dialing, central
STABTIM
Stabilization time for pos. messages and message pairs for a PCM link
The timer only goes into effect if message delay is switched on in central system data (AMO ZAND, branch ALLDATA, parameter MSGDELAY).
Type of Input
:
Single value, optional
Possible Values
:
30-180 sec
Default Value
:
180 sec
SUPPTIM
Suppression time for further error messages for PCM link
The timer only goes into effect if message delay is switched on in central system data (AMO ZAND, branch ALLDATA, parameter MSGDELAY).
Type of Input
:
Single value, optional
Possible Values
:
10-60 sec
Default Value
:
60 sec
T301
Timer T301
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
180 sec
T302
Timer T302
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
10 sec
T303
Timer T303
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
4 sec
T304
Timer T304
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
15 sec
T305
Timer T305
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
30 sec
T308
Timer T308
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
4 sec
T309
Timer T309
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
90 sec
T310
Timer T310
Type of Input
:
single value, optional
Possible Values
:
0 - 255
Default Value
10 sec
T313
Timer T313
Type of Input
:
single value, optional
Possible Values
:
0 - 255
Default Value
4 sec
T314
Timer T314
Type of Input
:
single value, optional
Possible Values
:
0 - 255
Default Value
4 sec
T316
Timer T316
Type of Input
:
single value, optional
Possible Values
:
0 - 255
Default Value
120 sec
T322
Timer T322
Type of Input
:
single value, optional
Possible Values
:
0 - 255
Default Value
4 sec
TAMOST
Timer AMO Supervision Timeout
Type of Input
:
single value, optional
Possible Values
:
0-255
Default Value
60 sec
TAROB
Timer for automatic redirection on busy
Type of Input
:
single value, 22. parameter of a min-1-group
Possible Values
:
numeric, 1-63
Default Value
10
TBID
timer callback interdigit
Type of Input
:
single value, optional
Possible Values
:
:numeric, 1-20
Default Value
:
5 SEC
:
:
TBL
Mapping tables between HICOM and Realitis DX
Type of Input
single value, mandatory
Possible Values
DXTGITR
Trunk-trunk barring
LCOSDRRG
Mapping table LCOSD to RRG
LCOSVRRG
Mapping table LCOSV to RRG
TRGCBG
Mapping table TRG to CBG
TDPNSSC
Timer DPNSS Collision
Type of Input
:
single value, optional
Possible Values
:
numeric, 0-50 in 100msec steps (range 0-5000 msec)
Default Value
:
5 (500 msec)
TEIVERIF
TEI is verified upon request by the partner.
Type of Input
:
Single value, optional
Possible Values
:
Y, N
Default Value
:
N
TEMPSIG
Temporary Signaling Connection
Type of Input
:
single value, optional
Possible Values
:
Y YES
N NO
Default Value
:
Y
TIDOP
DPNSS trunk identity (TID) option
Type of Input
:
single value, optional
Possible Values
:
Y YES
N NO
Default Value
:
N
TIPL
Timer to delay the sending of IPL Req after call is conn.
Type of Input
:
single value, 20. parameter of a min-1-group
Possible Values
:
numeric, 0-60, 63
TMDTYPE
TMD board type
Type of Input
:
single value, mandatory
Possible Values
TMDMOS
Board type MOS
TMDBOS
Board type BOS
TRG
Traffic restrictions group (Hicom)
Type of Input
1 to 8 single values, concatenated with &, optional
Possible Values
numeric, 0-15
TROPTBR
Timer ROPT Release - both end released
Type of Input
:
single value, optional
Possible Values
:
numeric, 1-100
Default Value
10
TROPTNR
Timer ROPT Release - neither end released
Type of Input
:
single value, optional
Possible Values
:
numeric, 0-100
Default Value
0
TSABMR
Timer DPNSS SABMR Retransmission
Type of Input
:
single value, optional
Possible Values
:
numeric, 0-255
Default Value
0 SEC
TTSC
TSC (Temporary Signalling Connection) Timer.
Type of Input
:
Single value, optional
Possible Values
:
4-12
Default Value
:
4
TWEOS
Timer wait for EOS from CORNET
Type of Input
:
single value, optional
Possible Values
:
numeric, 1-100
Default Value
60 SEC
TYPE
Selection of circuit types to be processed (memory addressing)
Type of Input
:
Single value, mandatory (CHANGE)
Single value, optional (DISPLAY, REGENERATE)
Possible Values
:
ANALOG
Circuit analog - NWWTK (DELETE)
CDG
Cornet dpnss1 gateway
CDGVAR
Country specific variants for cdg blocks
DIUC
DIUC modul
DIUS2
DIU-S2 modul
DIUS2VAR
Country specific variants for diu-s2 blocks
NWWTK
Networking wtk set type
TMD
TMDN64 module
UNWD
user/network definition
Type of Input
:
single value, optional
Possible Values
:
DPACN dpnss:a/cornet: network
DPACU dpnss:a/cornet: user
DPBCN dpnss:b/cornet: network
DPBCU dpnss:b/cornet: user
Default Value
DPACN
VARNO
Number of country specific variant on hard disk
Type of Input
1 to 2 single values, concatenated with &&, optional (DISPLAY)
ingle value, mandatory (COPY)
Possible Values
numeric,1-255
VCHCONF
dpnss virtual chanels x/y configuration
Type of Input
:
0 to 30 single values, concatenated with & or &&, optional
Possible Values
:
numeric, 1-30
Default Value
:
VERSION
Version of module (e.g. DIUS2)
Type of Input
:
Single value, optional
Possible Values
:
S1
US version
S2
S2 version
Default Value
:
S2
VMSYSTAD
Version of DIU-S2 module
Type of Input
single value, 2. parameter of a min-1-group
Possible Values
numeric, up to 22 characters
WINDOW
Maximum number of outstanding information(I) frames. when this figure is reached, transmission is suspended until a response frame is received. Value is specified in number of frames.
Type of Input
single value, 11. parameter of a min-1-group
Possible Values
1-127
Default Value
7