146.3.1
CHANGE-MFCTA
The action CHANGE allows the user to update data contained in existing, initialized MFC tables.
Procedure Overview
Command Code
Parameter
CHANGE-MFCTA
MFCVAR=<number>,
TYPE=MFCVAR
,OPT=MISC,{BACKTYPE=<param>,FORWTYPE=<param>
,IMP=<number>,PAR=<param>}
,CHEXAC=<param>,[EXACFI=<keynum>]
,CHTRDIS=<param>,[TRDISDI=<keynum>]
,CHLCLTR=<param>,[LCLTRCD=<keynum>]
,CHAREQ=<param>,[ADREQ=<keynum>];
|,OPT=SUPERV,{STADIAL=<number>,NXTSIG=<number>
,RMVSIG=<number>,CTLF=<number>
,RMVCTL=<number>,TNSIG=<number>
,IMPD=<number>,IMPS=<number>
,SIGLENF=<number>,NEXTSIG=<number>
,SPAU=<number>,SLEN1=<number>
,SLEN2=<number>,MFPPULS=<number>
,MFPPAUSE=<number>,IMP2=<number>
,MAXDGTS=<number>,WAITREC=<number>};
|TYPE=TBLB
,OPT=FSIG,PHYSIG=<number>,{SIG=<param>,
,IDX=<number>};
|,OPT=FORIB,EODTYPE=<param>,PHYSIG=<number>
,{ORIG=<param>,IDX=<number>};
|,OPT=FORIA,PHYSIG=<number>,{STNCAT=<param>
,DINFO=<param>,ADINFO=<number>
,COEX=<number>,COEXTRAN=<number>
,CATTRANS=<param>,ANICAT=<param>};
|,OPT=FIDENT,PHYSIG=<number>,SIG=<param>;
|,OPT=BSIGA|BSIGB|BSIGB1|BIDENT,EODTYPE=<param>
,{BSIG=<number>,INFO=<param>};
|,OPT=EVAL,EVTBL=<number>
,CHADGT=Y,[DGTS=<hex>];
|,CHADGT=N;
|TYPF=TBLF
,OPT=BSIGA|BSIGB|BSIGB1|BIDENT
,PHYSIG=<number>,SIGN=<param>;
|,ART=BSIG2,FSIG2=<param>,{PHYSIG=<number>
,IDX=<number>,CATEGORY=<number>};
|,OPT=FIDENT,{ID=<hex>,CNT=<number>
,PABXID=<hex>,PCNT=<number>
,POS1=<number>,POS2=<number>
,POS3=<number>,POS4=<number>
,ANBEG=<number>,ANEND=<number>
,APOS=<number>,BSDIRNO=<hex>
,BSDIRCNT=<number>,FILLCHAR=<number>};
|OPT=DIALOUT,PHYSIG=<number>, {(min 1)
DIGIT=<number>, INFO=<param>};