151.2.3
OUTPUT TRACE-DATA
After executing the command DISPLAY-PETRA the message H3 and the prompt "
*" is displayed asking the user to insert the parameter NO and CONT.
Instead of restarting the AMO, it is based on the DISPLAY action. This makes it possible to examine the data which were retrieved once, any number of times.
The rest of the AMO run is controlled with the second parameter CONT. As long as the parameter value is ’Y’, further DISPLAY commands can be input. After ’N’ the AMO is terminated and the internal PETRA data segment released.
Each individual data record of a module is 16x8 bit long, the first byte contains the LTU No., the second the PBC No., followed by 14 bytes of TRACE data. For TROSS51 modules these consist of individual 3 byte trace entries (1 empty bit, 2 bit flags, 5 bit circuit code and a 16 bit address); in the case of L3X and Rolm modules, on the other hand, the 14 bytes constitute one trace entry.
Procedure Overview
Command Code
Parameter
[NO=<number>],[CONT=<param>];
Examples
1.
The previously retrieved TRACE data are to be displayed and the AMO is subsequently to be ended.
Input:
,N;
2.
The last 100 of the data retrieved using the DISPLAY command are to be displayed.
Input:
100;
Output:
TRACE DATA FROM LTG 1
LTU SLOT CCT DATA
1 1 0 9234 A345 D678 ABCD 88EF 99FA
1 1 5 9234 D678 ABCD 88EF E7E7
LTU PBC CIRCUIT STATE PROC BOARD HEADER L3X HEADER DATA
4 11 0 3 4 8020 075 85 1 1 9A5A5A5
4 11 0 1 4 8620 0 3 4320A5 A5A5A5A5
LTU SLOT CCT TR-TAG DATA
3 79 0 0 010203040506 07080910111213
LTU SLOT CCT DATA
2 13 1 D432 A345 BADE AFFE 8080 8085 8086
2 37 0 FEDE BAFF E969 DAEF 9111 8194 C711 A921 B368 8926 B764