151.4
Error Messages and Advisories
151.4.1
Error Messages
F01:
CIRCUIT NOT PRESENT
The addressed circuit is not available, not active or larger than the maximum permissible value for this module.
F02:
BOARD NOT PRESENT
The addressed module is not available or not active.
F03:
LTU NOT PRESENT
The line trunk unit is not available, not active or larger than the maximum permissible value for this type of system.
F04:
LTG NOT PRESENT
The line trunk group is not available, not active or larger than the maximum permissible value for this type of system.
F05:
BOARD HAS NO PERIPHERAL TRACER
The module type determined for the specified address appears in the internal AMO table of untraceable modules. This also means that no message appears for new untraceable modules not yet included in the table (please notify PETRA developer).
F06:
UNEXPECTED TRACE TYPE: <xxxxxxxxxxxxxxxx> <xxxxxxxxxxxxxxxx>
Trace type is invalid; the trace item data are output for diagnostic purposes (please notify PETRA developer).
F07:
MOUNTING POSITION @@@T IN LTU-TYPE @@T CANNOT BE OCCUPIED
The entered mounting position (SLOT) is not valid for the current shelf type (LTU).
F08:
INVALID PROCESS-VALUE, PERMITTED RANGE: 0H TO FH
Only a maximum value of 15 processes is permitted to be entered for not ROLM modules.
F09:
INVALID TRACE-DATA FOR LTUR; PLEASE ENTER 2 CHAINED VALUES
Only two chained single values (0 - FF) are permitted to be entered as trace data for ROLM modules (e.g. LTUR).
F10:
PROCESSOR-IDENTIFICATION NOT ALLOWED FOR MODULE
The entered processor type is not valid for the selected module.
F11:
BOARD HAS NO DUMP FUNCTION
F12:
SPECIFIED LENGTH SMALLER THAN NUMBER OF INPUT HEX-VALUES