152.3
Parameter Description
ACTIVE
Release or blocking of the protocol for the CP
Type of Input
:
Single value, optional
Possible Values
:
YES, NO
KIND
Branch parameter for selecting wanted output data
Type of Input
:
Single value, mandatory (DISPLAY, CHANGE)
Possible Values
:
1st function DISPLAY
PVCDSHRT
Brief interrogation of protocol variant combination description
PVCDLONG
Interrogation of a protocol variant combination description (complete).
PDSHORT
Brief interrogation of the protocol descriptions
PDLONG
Detailed interrogation of a protocol description
VARTAB
Interrogation of the protocol variant descriptions
2nd function CHANGE
VARTAB
Changing the protocol variant description
PD
Changing the protocol description
BNO
Number of blocks (with max. of 60 bytes) to be output
(see function
DISPLAY-PRODE
)
Type of Input
:
Single value, optional
Possible Values
:
1 to 8
Default Value
:
8
Bxx
Contents of the xxth byte (B00 to B59)
Type of Input
:
Single value, optional
Possible Values
:
Two-digit hexidecimal
Group Condition
:
At least one byte must be specified
CS
Code set, used for further classification of the WELNAME table
Type of Input
:
Single value, optional (DISPLAY)
:
Single value, mandatory (CHANGE)
Possible Values
:
0-7
Default Value
:
0
IDENT
Identifier of the protocol
Type of Input
:
Single value, optional (CHANGE)
Possible Values
:
Two-digit hexidecimal
00 to FE
NO
Number of the byte for memory addressing
Type of Input
:
Single value, optional
Possible Values
:
0 to 500
Default Value
:
0
SRC
Branch parameter for selecting the origin of the
Type of Input
:
Single value, mandatory (DISPLAY)
Possible Values
:
HD Data to be output is on HD
DB Data to be output is in DB
PDA1
Name of first alternative protocol descriptor to be used
Type of Input
:
Single value, optional
Possible Values
:
See parameter PDNAME
PDA2
Name of second alternative protocol descriptor to be used
Type of Input
:
Single value, optional
Possible Values
:
See parameter PDNAME
PDBLK
Name used for addressing the PD table
Type of Input
:
Single value, mandatory
Possible Values
:
MTNAME, MTIDENT, WELHEX, STDWEL, HLCTAB, BCLLCTC,
BCLLCL1, TRSPEED, FACTAB, CAUNAME,CAUIDNT
WELNAME,TIMER, WELMAND
The parameter values are the set values of the memory
PDNAME
Name of the protocol in the database
Type of Input
:
Single value, optional (COPY)
Single value, mandatory (CHANGE,DISPLAY)
Possible Values
:
PD01, PD02, PD03, PD04, PD05, PD06, PD07,
PD08, PD09, PD10, PD11, PD12, PD13, PD14
PDNORM
Name of the standard protocol descriptor to be used
Type of Input
:
Single value, optional
Possible Values
:
See parameter PDNAME
PDNO
Number of the protocol on HD
Type of Input
:
Single value, mandatory (COPY)
Single value, &, &&, optional (DISPLAY)
Possible Values
:
1-50
The value specified is checked with the files on the HD.
PDSTRING
Text string for the description of a protocol
Type of Input
:
Single value, optional
Possible Values
:
Text, 25 chars.
PROTVAR
Protocol variant
Type of Input
:
Single value, mandatory (CHANGE)
Possible Values
:
ANALOG
"analog protocol"
CORNV2
CorNet protocol from SP300-V2.3
CORNV2R
CorNet protocol from SP300-V2.3
CORNV3
CorNet protocol from SP300-V3.1
CORNV3R
CorNet protocol from SP300-V3.1
CORNV33
CorNet protocol from SP300-V3.3
CORNV33R
CorNet protocol from SP300-V3.3
ECMA1
Protocol ECMA QSIG V1
ECMA1R
Protocol ECMA QSIG V1 reserved
ECMAV2
Protocol Cornet-NQ Issue 2.1 Dec.96 basis ETSI
ECMAV2R
Protocol qsig etsi ETS 300 172 3rd. with SS 2nd.
ETSI
Standard-EURO-ISDN
SWISNET2
Swissnet2,Swiss CO protocol
FRA
Numeris, French cornet co protocol
SPA
Protocol Spain
FIN
Protocol Finland
POR
Protocol Portugal
BEL
Protocol Belgium
DEN
Protocol Denmark
NDL
Netherlands
GB
Great Britain
AUST0
Australia T0
AUST2
Australia T2
Q931R5
Q931 reserve 5
Q931R6
Q931 reserve 6
Q931R7
Q931 reserve 7
Q931R8
Q931 reserve 8
CSN7
China 1
CSN7R2
China 2
PSS1V2
Protocol Cornet-NQ Issue 2.1 Dec.96 basis ETSI
PSS1V2R
Protocol qsig iso ISO/IEC 11572 2nd. with SS
RES3
Reserve protocol 3
RES4
Reserve protocol 4
RES5
Reserve protocol 5
RES6
Reserve protocol 6
EDSGER
Protocol EDSS1 Germany
EDSAUT
Protocol EDSS1 Austria
EDSSUI
Protocol EDSS1 Switzerland
EDSFRA
Protocol EDSS1 France
ETSI
Standard Euro ISDN
EDSR3
Protocol EDSS1 Reserve 3
EDSR4
Protocol EDSS1 Reserve 4
EDSR5
Protocol EDSS1 Reserve 5
EDSR6
Protocol EDSS1 Reserve 6
EDSR7
Protocol EDSS1 Reserve 7
EDSR8
Protocol EDSS1 Reserve 8
EDSS1NET
Protocol EDSS1 net side
EDSS1NETR
Protocol EDSS1 net side
SBEDSR1
Station protocol EDSS1 Reserve 1
SBEDSR2
Station protocol EDSS1 Reserve 2
SBEDSR3
Station protocol EDSS1 Reserve 3
SBEDSR4
Station protocol EDSS1 Reserve 4
SBQ9311
Station protocol Q931-1
SBDSS1
Station protocol DSS1
SS7ISUP
SS7-Isup Ref-T user side
SBNIBRI
SBNIBRI protocol
ATT4ESS
AT&T ISDN PRI
ATT4ESSR
AT&T ISDN PRI reserve
MCI250
DMS-250 ISDN PRI
MCI250R
DMS-250 ISDN PRI reserve
MCI600
DEX600 ISDN PRI
MCI600R
DEX600 ISDN PRI reserve
SPRINT
SPRINT ISDN PRI
SPRINTR
SPRINT ISDN PRI reserve
NI2
National ISDN PRI
NI2R
National ISDN PRI reserve
NI2NET
National ISDN PRI net side
NI2NETR
National ISDN PRI net side, reserve
CORNUS
Protocol CORNET-N for US
CORNUSR
Protocol CORNET-N for US, reserve
PVCDNO
PVCD number of protocol on HD
Type of Input
:
Single value, mandatory (COPY)
Single value, &, &&, optional (DISPLAY)
Possible Values
:
1-40
The value specified is checked with the files on the HD.
SETNO
Number for addressing the WELMAND table
Type of Input
:
Single value, optional (DISPLAY)
Single value, mandatory (COPY)
Possible Values
:
0-255
Default Value
:
0
SEC
Branch parameter for selecting the memory area
Type of Input
:
Single value,mandatory (CHANGE)
Possible Values
:
ORG
administration part
WELMAND
WELMAND table
WELNAME
WELNAME table
TIMER
TIMER table
RESTP
other tables defined by PDBLK
TIMEMS
Time in milliseconds
Type of Input
Single value, mandatory
Possible Values
0-999
TIMERID
Identification of timer
Type of Input
:
Single value, mandatory (CHANGE)
Single value, optional (DISPLAY)
Possible Values
:
T301, T302, T303, T304, T305, T306, T307,
T308, T309, T310, T311, T312, T313, T314,
T316, T317, T318, T319, T320, T321, T322,
T323, T382, T384, T385, T386, T30X2, T408
Description of
Timer T311 (the same terminology is in force as written in ITU-T Q.931 cahpter 9.2 "Timers in the user side"):
Timer Number:
T311
Time-out value:
5 .. 9 s ( T303 < T311 < T310 )
State of call:
U9 Incoming Call Proceeding
Cause for start:
CALL PROC sent
Normal stop
ALERT or DISC sent
At the first expiry:
Send ALERT
At the second expiry:
Timer is not restarted
Cross Reference:
Optional
TIMESEC
Time in seconds of timer defined by parameter TIMERID
Type of Input
:
Single value, mandatory
Possible Values
:
0-65535
TYPE
Branch parameter for COPY
Type of Input
:
Single value, mandatory
Possible Values
:
PVCD
All PDs belonging to a PVCD must be loaded
PD
A specific PD must be loaded
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.