154.4
Parameter Description
TYPE
Desired peripheral processing timers options
Type of Input
:
Single value, mandatory
Possible Values
:
REST
SLMA (resp. Optiset/OptiPoint)
SLMA1
TSAC
Parameters for the branch TYPE = SLMA:
Peripheral timers for SLMA modules resp. Optiset/OptiPoint, only ring timers.
The following condition must be satisfied:
FLASHMIN < FLASHMAX < ONHOOK.
FLASH
Time between detecting and reporting flash key
Type of Input
:
Single value, optional
Possible Values
:
0 - 2000 ms
Default Value
:
600 ms
FLASHMAX
Maximum flash time
Type of Input
:
Single value, optional
Possible Values
:
20 - 2000 ms
Default Value
:
110 ms
FLASHMIN
Minimum flash time
Type of Input
:
Single value, optional
Possible Values
:
20 - 2000 ms
Default Value
:
40 ms
INTERDIG
Interdigit pause
Type of Input
:
Single value, optional
Possible Values
:
50 - 2000 ms
Default Value
:
100 ms
ONHOOK
Minimum time for detection of on-hook state
Type of Input
:
Single value, optional
Possible Values
:
20 - 2000 ms
Default Value
:
200 ms
RNGOFF0
Inter-ring pause, single burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
4000 ms
RNGOFF11
Inter-ring pause, double burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
400 ms
RNGOFF12
Inter-ring pause, double burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
4000 ms
RNGOFF2
Inter-ring pause, single burst ring 2
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
1000 ms
RNGOFF31
Inter-ring pause 1, double burst ring 2
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
400 ms
RNGOFF32
Inter-ring pause 2, double burst ring 2
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
1000 ms
RNGOFF61
Inter-ring pause 1, triple burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
200 ms
RNGOFF62
Inter-ring pause 2, triple burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
200 ms
RNGOFF63
Inter-ring pause 3, triple burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
4000 ms
RNGON0
Ring times, single burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
1000 ms
RNGON11
Ring times, double burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
300 ms
RNGON12
Ring times , double burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
300 ms
RNGON2
Ring times, single burst ring 2
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
1000 ms
RNGON31
Ring time 1 , double burst ring 2
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
300 ms
RNGON32
Ring time 2 , double burst ring 2
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
300 ms
RNGON5
Alerting tone
(
not
Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
500 ms
RNGON61
Ring time 1, triple burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
200 ms
RNGON62
Ring time 2, triple burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
200 ms
RNGON63
Ring time 3, triple burst ring 1
(also Optiset/OptiPoint)
Type of Input
:
Single value, optional
Possible Values
:
20 - 60000 ms
Default Value
:
200 ms
SPCL
Cleardown timeout for special station during power-out on a/b wires
Type of Input
:
Single value, optional
Possible Values
:
50 - 2000 ms
Default Value
:
1000 ms (TBLK 0-15)
Parameters for the branch TYPE = SLMA1:
FLASH
Time between detecting and reporting flash key
Type of Input
:
Single value, optional
Possible Values
:
0 - 2000 ms
Default Value
:
600 ms
FLASHMAX
Maximum flash time
Type of Input
:
Single value, optional
Possible Values
:
110 - 2000 ms
Default Value
:
130 ms
(TBLK=0 , Spain)
1000 ms
(TBLK=1 , Spain)
350 ms
(TBLK=2 , France)
110 ms
(TBLK=3 - 15)
FLASHMIN
Minimum flash time
Type of Input
:
Single value, optional
Possible Values
:
20 - 2000 ms
Default Value
:
50 ms
(TBLK=0 , Spain)
50 ms
(TBLK=1 , Spain)
190 ms
(TBLK=2 , France)
40 ms
(TBLK=3 - 15)
INTERDIG
Interdigit pause
Type of Input
:
Single value, optional
Possible Values
:
50 - 2000 ms
Default Value
:
100 ms
ONHOOK
Minimum time for detection of on-hook state
Type of Input
:
Single value, optional
Possible Values
:
150 - 2000 ms
Default Value
:
150 ms
(TBLK=0 , Spain)
1100 ms
(TBLK=1 , Spain)
500 ms
(TBLK=2 , France)
200 ms
(TBLK=3 - 15)
PAUSED
SLMAR call charge pulse - pause duration (in 10 ms steps)
Type of Input
:
Single value, optional
Possible Values
:
0 - 2550 ms
Default Value
:
0 ms
PULSED
SLMAR call charge pulse - pulse duration (in 10 ms steps)
Type of Input
:
Single value, optional
Possible Values
:
0 - 2550 ms
Default Value
:
0 ms
SPCL
Cleardown timeout for special station during power-out on a/b wires
Type of Input
:
Single value, optional
Possible Values
:
50 - 2000 ms
Default Value
:
1000 ms
(TBLK 0-15)
TBLK
Timer block
Type of Input
:
Single value, optional
Possible Values
:
0 - 15
Parameters of the branch TYPE = TSAC:
ASSTYPE1
Assessment time for pulses to be received for IMPTYPE1. This establishes up to which length incoming pulses are evaluated as IMPTYPE1. Longer pulses are evaluated as IMPTYPE2 or, if the timer for evaluation range IMPTYPE2 (ASSTYPE2) has expired, result in timer overflow 1.
Type of Input
:
Single value, optional
Possible Values
:
35 bis 800 ms
Default Value
:
100 ms
ASSTYPE2
Assessment time for pulses to be received for IMPTYPE2. The timer is started after it expires for ASSTYPE1 and establishes up to which length pulses are evaluated as IMPTYPE2. The maximum pulse length is the sum of ASSTYPE1 and ASSTYPE2.
Type of Input
:
Single value, optional
Possible Values
:
35 bis 800 ms
Default Value
:
120 ms
IMPTYPE1
Length of pulses to be sent for type 1 (in ms) for
• Seizure ( TIE - 1)
• Start-of-pulse signal
• Answer
• Seizure acknowledgement
Type of Input
:
Single value, optional
Possible Values
:
40 to 800 ms in steps of 20ms
Default Value
:
60 ms
IMPTYPE2
Length of pulse to be sent for type 2 (in ms) for
• Gate seizure( TIE - 2 )
• End-of-selection
IMPTYPE2 must always be larger than IMPTYPE1.
Type of Input
:
Single value, optional
Possible Values
:
80 to 800 ms in steps of 20ms
Default Value
:
140 ms
RLSPBK
Length of backward release/release
acknowledgement pulse to be sent
Type of Input
:
Single value, optional
Possible Values
:
120 bis 4000 ms
Default Value
:
2300 ms
RLSPFW
Length of forward release pulse to be sent
Type of Input
:
Single value, optional
Possible Values
:
120 bis 4000 ms
Default Value
:
700 ms
TBLK
Timer block
Block in which the specified times are entered.
Type of Input
:
Single value, optional
Possible Values
:
0 bis 5
Description of the parameters of branch TYPE = REST:
BTYPE
Branching parameter for addressing LONGTIME, SHORTTIME and SHORTPARA-TBL for all remaining device types (TYPE=REST)
Type of Input
:
Single value, mandatory
Possible Values
:
LONG, SHORT, PARA
DEV
Device types
Device type to be specified for DISPLAY-PTIME:TYPE=REST
Type of Input
:
Single value, optional
Possible Values
:
see APPENDIX 1
TBLK
Timer block
Block in which the specified times are to be entered.
Type of Input
:
Single value, mandatory
Possible Values
:
0 bis 31
Note on the parameters LONG, SHORT, PARA for BTYPE
The above parameters are described in APPENDIX 2 because they vary with the device type used.
L1 - L 7
Parameters for LONG timer
S1 - S14
Parameters for SHORT timer
P1 - P14
Parameters for PARA
Description of the parameters of branch TYPE = REST:
INIBLOCK
Initialization block number in file on hard disk (see Appendix)
Type of Input
:
numerical, mandatory
Possible Values
:
0 - 255
If INIBLOCK = 0, a timer block will be deleted.
In this case, the parameter TBLK must be specified.
TBLK
Number of timer block in database
Block in which the specified times are entered.
Type of Input
:
Single value, mandatory (for INIBLOCK = 0)
Single value, optional (for INIBLOCK > 0)
Possible Values
:
0 to 31
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.