155.2.2
CHANGE-RCSU
Parameters of a created recorder can be changed by means of the function CHANGE-RCSU. With the exception of PEN, all parameters are optional, but at least one of the optional parameters must be entered.
A recorder which is in the ready state cannot have data changed unless deactivated by AMO DSSU. When a random start recorder is deactivated, it should be an immediate deactivation (DEA-DSSU:DI,...) whereas the fixed start recorder can be deactivated conditionally (DEA-DSSU:DC,...) or immediate. To determine the status of the recorder, use AMO SDSU (DIS-SDSU:,,PEN,PER3, <LTG>,<LTU>,<SLOT>,<CIRC>;).
The entered parameters are checked together with the unchanged parameters, as in the case for the function ADD.
The recorder application type (RECAPL) may be changed. If changed to ACDR and the parameter RECNUM is not input, it will be defaulted to the first logical recorder number available for ACD recorded announcements. The LENGTH parameter will be defaulted if the OPTYPE is RANDOM; but if the recorder is FIXED, the LENGTH must be entered. If changed to ACDMUS, the parameter MUSNUM will be defaulted to the first available number for ACD music recorders.
A recorder that is referenced by either AMO DNIT or AMO ACDRT can not have the following parameters changed: OPMODE, OPTYPE, RECAPL, RECNUM or MUSNUM. The parameter LENGTH may be changed even if the recorder is referenced.
Procedure Overview
Command Code
Parameter
CHANGE-RCSU
PEN=<GG-UU-BBB-SS>,[OPMODE=<param>],[OPTYPE=<param>]
,[COFIDX=<number>],[CCTIDX=<number>],[CLASSMRK=<param>]
|,[RECAPL=ACDR],[RECNUM=<number>],[LENGTH=<number>];
|,[RECAPL=ACDMUS],[MUSNUM=<number>];
|,[RECAPL=HMUSIC],[HMUSIC=<number>];
Examples:
1.
Change the RECNUM of a recorded announcement for ACD at 1-2-13-5.
Input:
CHANGE-RCSU:PEN=1-2-13-05,RECAPL=ACDR,RECNUM=4;
Output:
H06: RECORDER AT PORT 01-02-013-05 HAS BEEN CHANGED.
2.
Change RECAPL,OPMODE, and OPTYPE for recorder at 1-5-13-0;
Input:
CHANGE-RCSU:PEN=1-5-13-00,OPMODE=CONT,OPTYPE=RANDOM,RECAPL=ACDMUS;
Output:
H06: RECORDER AT PORT 01-05-013-00 HAS BEEN CHANGED.