155.4
Error Messages and Advisories
155.4.1
Error Messages
F01:
INVALID PORT POSITION:'LTG' (LINE TRUNK GROUP) FOR 'PEN' OUT OF RANGE.
F02:
INVALID PORT POSITION:'LTU' (LINE TRUNK UNIT) FOR 'PEN' OUT OF RANGE.
F03:
INVALID PORT POSITION:'SLOT' (BOARD SLOT NUMBER) FOR 'PEN' INCORRECT.
F04:
INVALID PORT POSITION:
'CIRCUIT' (BOARD CIRCUIT NUMBER) FOR 'PEN' INCORRECT.
F05:
MEMORY RESERVED FOR SUBSCIBERS (NEEDED FOR THE
CONFIGURATION OF ANNOUNCEMENT RECORDERS) IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-DIMSU:STN=<?>;
F06:
NO DEVICE CONFIGURED. INCORRECT TYPE OF BOARD AT 'SLOT' OF 'PEN'.
F07:
BEFORE ACTIONS CHANGE/DELETE PLEASE DEACTIVATE
THE RECORDER WITH THE FOLLOWING COMMAND:
DEACT-DSSU:OFFTYPE=DI,TYPE=PEN,PEN1=<?>;
F09:
THE 'PEN' SPECIFIED IS ALREADY USED.
(AMO @@@@@,PEN=@@-@@-@@@-@@@)
(AMO @@@@@,STNO=@@@@@@)
F10:
NO PERIPHERAL MODULE CONFIGURED YET FOR THE 'SLOT' OF 'PEN'.
(SEE AMO BCSU,MTYPE=PER)
F11:
NO FREE PORT FOR RECORDERS FOUND ON THE APPROPRIATE MODULES.
F12:
NO RECORDER CAN BE ATTACHED TO THE GIVEN 'SLOT' OF
'PEN'. BOARD MISSING OR OF INCORRECT TYPE:
ONLY MODULES OF TYPE 'SLMA, SLMAB, SLMA3, SLMA24'
ARE ALLOWED (SEE AMO BCSU, MTYPE=PER).
F13:
CANNOT CHANGE DATA - NO RECORDER CONFIGURED YET
FOR PORT PEN=@@-@@-@@@-@@.
F15:
MEMORY RESERVED FOR LODEN VALUES (LOGICAL DEVICE
TABLE NUMBERS FOR CALL PROCESSING) IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-DIMSU:LODEN=<?>;
F16:
MEMORY RESERVED FOR DEVICE TABLE ENTRIES
(DEVICE HANDLER) IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-DIMSU:LTGNO=<?>,DTILTG=<?>;
F17:
MEMORY RESERVED FOR SUB-UNIT POOL
(CALL PROCESSING) IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-DIMSU:SU=<?>;
F18:
MEMORY RESERVED FOR
DEVICE INDICATOR POOL (DEVICE HANDLER) IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-DIMSU:LTGNO=<?>,DILTG=<?>;
F19:
THIS COMMAND INPUT DOES NOT INDUCE CHANGES IN CURRENT CONFIGURATION DATA.
F20:
THE 'PEN' SPECIFIED IS USED BY A DIFFERENT TYPE
OF DEVICE (NOT AN ACD RECORDER).
F21:
CANNOT CHANGE DATA - NO RECORDER CONFIGURED YET
FOR PORT PEN=@@-@@-@@@-@@.
BOARD MISSING OR OF INCORRECT TYPE:
ONLY MODULES OF TYPE 'SLMA, SLMAB, SLMA3, SLMA24'
ARE ALLOWED (SEE AMO BCSU, MTYPE=PER).
F25:
MUSIC-ON-HOLD HMUSIC=@@@ HAS ALREADY BEEN ASSIGNED.
F26:
THE UPPER LIMIT FOR THE NUMBER OF RECORDERS
IN THE SYSTEM HAS BEEN ATTAINED.
F27:
OPTYPE=RANDOM IS NOT ALLOWED TO BE SET WITH OPMODE=DEMAND.
F28:
OPTYPE=FIXED IS NOT ALLOWED TO BE SET WITH OPMODE=CONT.
F29:
FEATURE "FLEX+TDM" HAS BEEN ATTAINED. USE 'DISP-CODEW'
F34:
THERE IS NO RECORDER CONFIGURED FOR THE 'PEN' ENTERED.
F35:
THE UPPER LIMIT FOR THE NUMBER OF RECORDERS
WITH THIS APPLICATION HAS BEEN ATTAINED.
F36:
ACD ANNOUNCEMENT RECNUM=@@@ HAS ALREADY BEEN CONFIGURED.
F37:
ACD MUSIC MUSNUM=@@ HAS ALREADY BEEN CONFIGURED.
F38:
THE RECORDED ANNOUNCEMENT LENGTH (LENGTH)
ENTERED IS INCORRECT FOR OPTYPE=FIXED.
POSSIBLE VALUES: 1,2,...,13,14,15,20,...,85,90.
F39:
THE RECORDED ANNOUNCEMENT LENGTH (LENGTH)
ENTERED IS INCORRECT FOR OPTYPE=RANDOM.
POSSIBLE VALUES: 1,2,...,15,16.
F40:
AN ACD RECORDED ANNOUNCEMENT WITH OPTYPE=FIXED
MUST HAVE AN ANNOUNCEMENT LENGTH (LENGTH).
POSSIBLE VALUES: 1,2,...,13,14,15,20,...,85,90.
F43:
CANNOT DELETE RECORDER - IT IS STILL REFERENCED BY DNI TABLES.
(SEE AMO DNIT, TBL=DNI, AUDSRCID)
F44:
CANNOT DELETE RECORDER - IT IS STILL
REFERENCED BY ACD ROUTING TABLES.
(SEE AMO ACDRT, ACT=RTREC, ACT=RTMUS)
F45:
THE FIELDS 'OPMODE, OPTYPE, RECAPL, RECNUM, MUSNUM'
CANNOT BE CHANGED - THE RECORDER IS STILL
REFERENCED BY ACD ROUTING TABLES.
(SEE AMO ACDRT, ACT=RTREC, ACT=RTMUS)
F46:
THE FIELDS 'OPMODE, OPTYPE, RECAPL, RECNUM'
CANNOT BE CHANGED - THE RECORDER IS STILL
REFERENCED BY DNI TABLES.
(SEE AMO DNIT, TBL=DNI, AUDSRCID)
F47:
A MUSIC-ON-HOLD RECORDER (RECAPL=HMUSIC)
MUST HAVE OPMODE=CONT AND OPTYPE=RANDOM.
F49:
A MUSIC RECORDER (RECAPL=ACDMUS)
MUST HAVE OPMODE=CONT AND OPTYPE=RANDOM.
F50:
THE MODULE OF PORT PEN=@@-@@-@@@-@@ HAS BEEN DEACTIVATED.(SEE AMO BSSU)
F51:
RECORDER CANNOT BE CHANGED OR DELETED - IT IS STILL
BEING ASSIGNED TO SUBSCRIBERS.
(DISP-RCSU:RECAPL=HMUSIC,HMUSIC=@@@,REFRN=YES;)
F52:
THE CLASSMRK VALUES 'INIT' OR 'NONE' MAY NOT BE"
CONCATENATED.
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.