167.3.2
CHANGE-SCREN
This action changes the screening data and/or the screening pattern plan of a source node number.
Before the screening pattern plan of a source node number can been changed the plan must have been configured with screening patterns.
If no screening pattern plan SCRPPLAN but the type of plan SCRPTON is entered, the change command will not be performed.
If no default number operator DNO but the type of default number operator DNOTON is entered, the change command will not be performed.
Procedure overview
Commandcode
Parameter
CHANGE-SCREN
SNNO=<number>, {(min 1) [DNO=<key-num>],
[DNOTON=<param>], [TOSCAL=<param>],[PRESCAL=<param>],
[TOSCOL=<param>], [PRESCOL=<param>],
[SCRPPLAN=<number>], [SCRPTON=<param>],
[LOCDEST=<key-num>]};
Example
1.
Change the screening data (DNO, TOSCAL, SCRPTON) of source node number 12-343.
Input:
CHANGE-SCREN:SNNO=12-343,DNO=56667*88787,TOSCAL=SPECARR,SCRPTON=NATIONAL;