167.4
Parameter Description
DATATYPE
Type of screening data to be deleted
Type of Input
:
0 to 9 single values, concatenated with &, optional
Possible Values
:
DNO
= default number operator
DNOTON
= type of default number operator
LOCDEST
= origin local destination code
PRESCAL
= presentation of calling line number
PRESCOL
= presentation of connected line number
SCRPPLAN
= screening pattern plan
SCRPTON
= type of screening pattern plan
TOSCAL
= type of screening calling line number
TOSCOL
= type of screening connected line number
DNO
Default number operator
Type of Input
:
single value, 1. parameter of a min-1-group, up to 22 characters (CHANGE)
single value, optional, up to 22 characters (ADD,TYPE=SCRDATA)
Possible Values
:
0-9,*
DNOTON
Type of default number operator
Type of Input
:
single value, 2. parameter of a min-1-group (CHANGE)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
INTERNAT
= international number
NATIONAL
= national number
SUBSCR
= local subscriber number
UNKNOWN
= unknown number
Default Value
:
none (field is empty for DISPLAY/ REGENERATE)
LOCDEST
Origin local destination code
Type of Input
:
single value, 9. parameter of a min-1-group, up to 6 characters (CHANGE)
single value, optional, up to 6 characters (ADD,TYPE=SCRDATA)
Possible Values
:
0-9,*,#,A-D
PRESCAL
Presentation of calling line number
Type of Input
:
single value, 4. parameter of a min-1-group (CHANGE)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
CLIPPERM
= presentation of permanent A-subscriber, no restriction
CLIPDEF
= presentation of default A-subscriber, restriction per call
CLIRPERM
= restriction of permanent A-subscriber, no presentation
CLIRDEF
= restriction of default A-subscriber, presentation per call
Default Value
:
CLIPDEF
PRESCOL
Presentation of connected line number
Type of Input
:
single value, 6. parameter of a min-1-group (CHANGE)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
COLPPERM
= presentation of permanent B-subscriber, no restriction
COLPDEF
= presentation of default B-subscriber, restriction per call
COLRPERM
= restriction of permanent B-subscriber, no presentation
COLRDEF
= restriction of default B-subscriber, presentation per call
Default Value
:
COLPDEF
SCRP
Screening pattern
Type of Input
:
1 to 10 single values, concatenated with &, mandatory, up to 22 characters (ADD,TYPE=SCRPATT)
1 to 10 single values, concatenated with &, optional, up to 22 characters (DELETE,TYPE=SCRPATT)
Possible Values
:
0-9,*,X,#
SCRPOUT
Output of screening patterns
Type of Input
:
single value, optional
Possible Values
:
Y
= yes
N
= no
Default Value
:
N
SCRPPLAN
Screening pattern plan
Type of Input
:
1 to 10 single values, concatenated with &, optional
(DISPLAY,TYPE=SCRPATT / REGENERATE,TYPE=SCRPATT)
single value, 7. parameter of a min-1-group (CHANGE)
single value, mandatory
(ADD,TYPE=SCRPATT / DELETE,TYPE=SCRPATT)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
numeric, 0-65535 (ADD,TYPE=SCRDATA)
numeric, 1-65535
(ADD,TYPE=SCRPATT / DELETE,TYPE=SCRPATT / DISPLAY,TYPE=SCRPATT / REGENERATE,TYPE=SCRPATT / CHANGE)
Default Value
:
0 (ADD,TYPE=SCRDATA)
all (DISPLAY/ REGENERATE)
SCRPTON
Type of screening pattern plan
Type of Input
:
single value, 8. parameter of a min-1-group (CHANGE)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
INTERNAT
= international number
NATIONAL
= national number
SUBSCR
= local subscriber number
UNKNOWN
= unknown number
Default Value
:
none (field is empty for DISPLAY/ REGENERATE)
SNNO
Source node number
Type of Input
:
1 to 3 single values, concatenated with -, mandatory
(ADD,TYPE=SCRDATA / DELETE,TYPE=SCRDATA / CHANGE)
1 to 3 single values, concatenated with -, optional
(DISPLAY,TYPE=SCRDATA / REGENERATE,TYPE=SCRDATA)
Possible Values
:
numeric, 0-999 (level2-level1-level0)
level0: 0-999
level1: 0-253
level2: 0-29
TOSCAL
Type of screening calling line number
Type of Input
:
single value, 3. parameter of a min-1-group (CHANGE)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
NOSCR
= no screening
SCREEN
= number permitted for screening
SPECARR
= any national or international number permitted
Default Value
:
NOSCR
TOSCOL
Type of screening connected line number
Type of Input
:
single value, 5. parameter of a min-1-group (CHANGE)
single value, optional (ADD,TYPE=SCRDATA)
Possible Values
:
NOSCR
= no screening
SCREEN
= number permitted for screening
SPECARR
= any national or international number permitted
Default Value
:
NOSCR
TYPE
Type of screening data
Type of Input
:
single value, mandatory (ADD / DELETE)
single value, optional (DISPLAY / REGENERATE)
Possible Values
:
SCRDATA
= screening data
SCRPATT
= screening patterns
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.