175.3
Functions of the AMO
•
ADD-SIGNL
:
–
(TYPE=EVT) Create a new individual message (CD and NO) within a message class (U1020 -> Fxxxx).
–
(TYPE=FST) Create elements in the error element special table.
–
(TYPE=FMTEXT) Create a user defined text to a particular message. This text will be displayed in short format only.
•
ACTIVATE-SIGNL
:
–
(SWITCH=IMPTMSG) The devices enterd in this function will forced receive all reststart messages and special events, independent of other settings
–
(SWITCH=FILTER) The devices enterd in this function will receive service relevant messages only
–
(SWITCH=ALLMSG) The devices enterd in this function will receive all messages independent of other settings
–
(SWITCH=SHORTFM) The devices enterd in this function will receive messages in short form
•
DEACTIVATE-SIGNL
:
–
(SWITCH=IMPTMSG) Above function for entered devices deactivated
(SWITCH=FILTER) Above function for entered devices deactivated
–
(SWITCH=ALLMSG) Above function for entered devices deactivated
–
(SWITCH=SHORTFM) Above function for entered devices deactivated
•
CHANGE-SIGNL
:
–
(TYPE=EVT) Change the data of a defined message class (status, current and configured symbolic devices).
–
(TYPE=MID) Change the data of an error element or a signalling message.
–
(output authorization, priority, current and configured devices).
–
(TYPE=NID) Change the message identification (MID) of an already defined signalling message.
–
(TYPE=FST) Change the priority of elements in the error element special table.
•
DELETE-SIGNL
:
–
(TYPE=EVT) Delete symbolic devices within message classes and/or altogether
–
(TYPE=MID) Delete the symbolic devices of one or more signalling messages.
–
(TYPE=AL) Delete the alarm memory (AL) in the Attendant Console Task (ACT).
–
(TYPE=SIT) Delete the SIT-internal error statistics table.
–
(TYPE=FST) Delete elements from the error element special table.
–
(TYPE=FMTEXT) Delete an element from the FMTEXT table.
•
SET-SIGNL
:
Set the current output device to the configured standard device assignment
–
(TYPE=EVT) for one, two or more or all message classes.
–
(TYPE=MID) for one or more signalling messages;
•
DISPLAY-SIGNL
:
–
(TYPE=ALL) Display the names (discrete single values of the current implemented message class with specification of numeric values message classes not implemented.
–
(TYPE=EVT, FORMAT=STA) Display the status
–
(FREE, LOCK, UNDEF, OOS) of one, two or more or all message classes.
–
(TYPE=EVT, FORMAT=SEV) Display the error messages allocated to one, two or more or all message classes in table form.
–
(TYPE=MID) Display the the data of an error element for a signalling message:
Output authorization - S-FREE
Priority - AFR-PRIO
current symbolic devices - DEV-ACT
configured symbolic devices - DEV-KONF
–
(TYPE=SIF) Display the SIT-internal error statistics table.
–
(TYPE=FST) Display elements of the error element special table.
–
(TYPE=LOCKMSG) Display messages that cannot be output for any reason, e.g locked.
–
(TYPE=SYSTEM) Display system status information:
- state og CCA,CCB,ADP
- state of reference clock
- state of failure switchover
- alarms
–
(TYPE=STATUS) Display settings of IMPTMSG, ALLMSG, FILTER, SHORTFM, user defined FMTEXT, LOCK settings
•
REGENERATE-SIGNL
:
–
Regenerate all settings administered by the
AMO-SIGNL.