175.3.2
ACTIVATE-SIGNL
Setting of
1.
the set of devices that have to get any restart messages and special events independently of other settings (IMPTMSG = important messages).
2.
the set of devices that have to get service relevant messages only. Other messages are suppressed (FILTER)
3.
the set of devices that have to get all messages independently of other settings (ALLMSG).
4.
the set of devices that have to get short messages (SHORTFM, see above)
Prozedure overview
Command Code
Parameter
ADD-SIGNL
SWITCH=IMPTMSG,DEV=<param>
SWITCH=FILTER,DEV=<param>
SWITCH=ALLMSG,DEV=<param>
SWITCH=SHORTFM,DEV=<param>
Examples
1.
Activating several devices for the switch function FILTER
Input:
ACT-SIGNL:FILTER,DPT2&AFR1&AC;
Output:
ACT-SIGNL:FILTER,DPT2&AFR1&AC;
H500: AMO SIGNL STARTED
AMO-SIGNL-... SIGNALLING CONTROL
ACTIVATE COMPLETED;
2.
Activating one device for SWITCH funktion ALLMSG
Input:
ACT-SIGNL:ALLMSG,DPT3;
Output:
ACT-SIGNL:ALLMSG,DPT3;
H500: AMO SIGNL STARTED
AMO-SIGNL-... SIGNALLING CONTROL
ACTIVATE COMPLETED;
3.
activating several devices for the switch function SHORTFM
Input:
ADD-SIGNL:SHORTFM,DPT1&AC&AFR2&AFR3;
Output:
ADD-SIGNL:SHORTFM,DPT1&AC&AFR2&AFR3;
H500: AMO SIGNL STARTED
AMO-SIGNL-... SIGNALLING CONTROL
ACTIVATE COMPLETED;