175.3.4
CHANGE-SIGNL
The following data can be changed:
1.
the status, current and configured symbolic devices or one, two or more or all message classes;
2.
the data of an error element for a signalling message;
3.
the message identification (MID);
4.
the priority of elements in the error element special table (FST).
Note
The symbolic devices are added to those already generated.
Procedure Overview
Command Code
Parameter
CHANGE-SIGNL
TYPE=EVT,EVT=<param>,{[STATE=<param>],[ASD=<param>]
,[CSD=<param>]};
TYPE=MID,CD=<param>,NO=<number>,{[OUT=<param>]
,[PRI=<param>],[ASD=<param>],[CSD=<param>]};
TYPE=NID,OLDCD=<param>,OLDNO=<number>
,NEWCD=<param>,NEWNO=<number>;
TYPE=FST,NO=<number>,ACTION=<param>,PRI=<param>;
Example
Change the priority of error message 3062 to E4.
Input:
CHANGE-SIGNL:MID,F,3062,,E4;
Output:
CHANGE-SIGNL:MID,F,3062,,E4;
H500: AMO SIGNL STARTED
AMO-SIGNL -... ERROR SIGNALLING CONTROL
CHANGE COMPLETED;