180.2.1
ADD-SSC
The parameter PEN (= port) designates the terminal connection at which the special station is connected. If the PEN parameter is not entered, the system is searched for an available port.
The entered parameters cannot be altered.
A special station can only be cancelled and newly created.
Procedure Overview
Command Code
Parameter
ADD-SSC
[PEN=<gg-uu-bbb-ss>]
,TYPE=MSGR,MSGRNO=<number> (1)
,[COFIDX=<number>],[INS=<param>];
|TYPE=GENANS,UNANO=<number> (2)
,[COFIDX=<number>],[INS=<param>];
|TYPE=CC,CCNO=<number> (3)
,[COFIDX=<number>],ITR=<number>,[INS=<param>];
|TYPE=VMXMWI,MSTNO=<number> (4)
,[COFIDX=<number>],COS=<number>
,LCOSV1=<number>,[DPLN=<number>]
,[INS=<param>];
|TYPE=EXTANN,CPCALL=<param> (5)
,[COFIDX=<number>],[CLASSMRK=<param>];
,[LTU=<number>];
Examples
1.
Create and put into service a messenger station with STNO 101. An available port is to be allocated by the AMO.
Input:
ADD-SSC:,MSGR,101,,Y;
Output:
H01: THE MSGR USER 101 WAS ADDED IN LOCATION 1-1-1-1.
2.
Create a CC station with STNO 9 at port 1-1-1-0, allocate to traffic relations group 15 and put into service.
Input:
ADD-SSC:1-1-1-0,CC,9,0,15,Y;
Output:
H01: THE CC USER 9 WAS ADDED IN LOCATION 1-1-1-0.
3.
Create an EXTANN station with CPCALL=EXTDTN, the PEN will be searched by AMO.
Input:
ADD-SSC:,EXTANN,EXTDTN,1,;
Output:
H05: AT LOCATION 1-4-79-1, THE EXTANN USER WITH THE FOLLOWING CP CALL TONES
WAS ADDED:
EXTDTN
4.
To the EXTANN station at port 1-4-79-1 will be added the CP-Calls INTDTN and BUSY. Reset classmarks to EC&G711.
Input:
ADD-SSC:1-4-79-1,EXTANN,INTDTN&BUSY,EC&G711;
Output:
H08: TO THE EXTANN SUBSCRIBER AT LOCATION 1-4-79-1,
THE FOLLOWING CPCALL TONES HAVE BEEN ADDED:
INTDTN&BUSY
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.