180.3
Parameter Description
CCNO
Code calling access code (STNO of the CC terminal connection)
The CCNO must not be assigned yet. The size of the STNO range depends on the maximum number of single CC.
Type of Input
:
single value, mandatory
Possible values
:
0 - 9
CLASSMRK
DNIL classmarks (for feature IPDA)
Type of Input
:
max. 4 single values, concatenated with ’&’, optional
(ADD)
VAD
voice activity detection
EC
echo cancellation
G711
no voice compression, according to G.711
G729
voice compression (mandatory) according to G.729A
G729OPT
voice compression (optional) according to G.729A
INIT
initialisation of classmarks to default
NONE
deactivation of all classmarks
Default Value
EC&G711&
G729OPT
COFIDX
Index of COFI data file to be loaded
(index of a data block with which the SICOFI components must be loaded on an SLMA)
Type of Input
:
single value, optional
Possible values
:
0- data block for short lines (L < 100 m)
1- data block for lines of medium length
(100 m < L < 1000 m)
2- data block for long lines (L > 1000 m)
Default Value
:
0
COS
Class of service
Type of Input
:
single value, mandatory
Possible values
:
0 - 1199
CPCALL
HICOM-signal.
Every CPCALL belongs to one EXTANN.
Type of Input
:
single value, 1 to max. 16 values,
optional (ADD, DELETE)
Possible values
:
ALERT
notification/alert tone,
ANNICPT
announcement for attendant intercept,
BONHK
B party on hook,
BUSY
busy tone,
CAMP
knocking/camp-on/call waiting tone,
CBKALERT
call back alert tone,
CONFTN
conference tone,
CONG
congestion tone,
DATA
data tone,
DND
do not disturb tone,
EXTDTN
external dial tone,
EXTDTN2
secondary CO dial tone,
FRNGBK
fist burst of ringback tone,
HOLDLINE
hold the line please
NOPO
not possible,
IMPOSSFM
impossible for the moment,
INTDTN
internal dial tone,
KNCONF
camp-on tone for conference,
LOCANN
local announcement,
MUSIC
music on hold,
MWI
message waiting information,
NACK
negative acknowledgement tone,
NODIAL
timeout tone if digits not dialed,
NOTALWD
not allowed,
NOTREACH
not reachable,
NU
number obtainable tone,
OVR
automatic override tone,
OVRTN
override tone,
OVRWARN
override warning tone,
PACK
positive acknowledgement tone,
PACKWD
positive ack. tone with dialing,
REORDER
reorder tone,
RNGBK
ringback tone,
RTO
RTO test tone,
SPEC
special dial tone,
TEST
test tone,
VOICEMAL
voice mail,
HOLD
call waiting tone
DISCTONE
disconnect tone
HOLDEXT
holdtone external
HOLDH1
holdtone hold 1
HOLDH2
holdtone hold 2
HOLDINT
holdtone internal
HOLDCC
holdtone for code calling syst.
HOLDHT
holdtone for hunting group
FCAMP
first camp on tone
HOLDHT
call monitoring alerting tone
CCMABSEN
ccm tracer in rack
DPLN
Dial plan group
Type of Input
:
single value, optional
Possible values
:
0 - 15
Default Value
:
0
INS
Station in service?
(putting the terminal connection into service by means of the centralized device status administration)
Type of Input
:
single value, optional
Possible values
:
Y, N
Default Value
:
Y
ITR
Internal traffic restriction group / closed user group
Type of Input
:
single value, mandatory
Possible values
:
0 - 15
LCOSV1
LCR class of service 1
Type of Input
:
single value, mandatory
Possible values
:
1 - 32
LTU
LTU Number
Type of Input
:
1 to 4 single values, concatenated with & or &&, optional
Possible values
:
numeric, 1-15, 17-99
MSGRNO
Messenger station number
The MSGRNO must not be assigned yet.
The MSGRNO must not be greater than the STNO + the
maximum number of executive/secretary systems.
Type of Input
:
single value, mandatory
Possible values
:
101 - 999
MSTNO
VMX message waiting information station number
Type of Input
:
single value, mandatory
Possible values
:
0 - 9
PEN
Port equipment number of station
(terminal connection of the special station: LTG-LTU-SLOT-CCT)
If an entered module is not specified within the "6" grouping, it is automatically corrected to the next lowest permitted trunk number.
Type of Input
:
single value, optional (g-uu-sss-ccc)
Possible values
:
g
= LTG Number: 1 (no other value)
uu
= LTU Number: 1-15 in HHS (host Shelf)
17-99 in AP (Access Point Shelf)
16 not defined
sss
= SLOT Number: 1-121; slot in groups of 6
except 61 or 25-121 except 73 for compact shelfs
ccc
= Circuit Number: 0-254
A suitable module must be configured to the slot addressed by PEN (AMO BCSU).
The possible LTU and Slot values for PEN depend on the systems architecture and can be found in the BCSU AMO description.
The possible Line values depend on the module type and its functionality.
They can be listed using DISP-BCSU: TYPE=PEN [,LTG=, LTU=, SLOT=, CCT=]; which will also output the actual PEN status (e.g. NOT CONNECTED).
TYPE
Special station type
Type of Input
:
single value, mandatory
Possible values
:
MSGR, GENANS, CC, VMXMWI
(TYPE=ALL is also possible for DISPLAY)
UNANO
Device number of night answer station / bell (STNO of the GENANS terminal connection) The UNANO must not be assigned yet. The size of the STNO range depends on the maximum number of answering stations.
Type of Input
:
single value, mandatory
Possible values
:
0 - 15