184.2.1
DISPLAY-SYNC
Outputting the version statuses of the SEAT. AMO SYNC reads the version statuses of the SEAT from the file on hard disk which SE uses for restart-proof saving of this data.
Procedure Overview
Command Code
Parameter
DISPLAY-SYNC
;
Example
Input:
DISPLAY-SYNC;
Output:
+---------------------------------------------------------------+
| SEAT OF SURVEILLANCE ENTITY |
+-------+-------------+-------------+-------------+-------------+
| | SWU | ACD | EMML | EEA |
| AMO |ACTUAL|SHOULD|ACTUAL|SHOULD|ACTUAL|SHOULD|ACTUAL|SHOULD|
+-------+------+------+------+------+------+------+------+------+
| |4 |4 |0 |0 |0 |0 |0 |0 |
| SCSU |2 |2 | | | | | | |
| PERSI |4 |4 | | | | | | |
+-------+------+------+------+------+------+------+------+------+
Note
The first entry of the seat-table (without AMO-Noun) is the backupentry. The backupentry shows the logbooknumber of the SE (e.g. 4) and the state of the serveral services. If the SHOULD-value of the backupentry of a service is not equal 0 , that means that the service is activated.