190.4
Parameter Description
CATALOG
Catalog in which the mailbox of the receiver task is catalogued
Type of Input
:
Single value, mandatory
Possible Values
:
MODUL
The mailbox is catalogued in modul catalog.
SYSTEM
the mailbox ist catalogued in system catalog.
CATTYPE
How is the mailbox of the receiver task catalogued
Type of Input
:
Single value, mandatory
Possible Values
:
NAME
The mailbox is catalogued by name.
INDEX
The mailbox is catalogued by index.
DESTPROC
Identification of the destination processor
Type of Input
:
Single value, mandatory
Possible Values
:
A1
ADS
BPA
Base Processor A
BPB
Base Processor B
BPS
Base Processor stand-by
C1
Call charge server
GP1A
Group Processor 1 A
GP1B
Group Processor 1 B
.
.
.
.
GP32A
Group Processor 32 A
GP32B
Group Processor 32 B
T1
Tele-Communications Service 1
T2
Tele-Communications Service 2
T3
Tele-Communications Service 3
V1
Voice Mail Service 1
V2
Voice Mail Service 2
V3
Voice Mail Service 3
DIGIT
Test parameter for DIALOG and WRT/READ message.
Background parameter for test step 10 and 11.
Type of Input
:
Single value, optional
Possible Values
:
0 to 9
FUNCT
Selection of function
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 15, 16, 99.
See Functional Overview for an explanation of the values.
IB
Value initialization for bytes of a message segment
Type of Input
:
Single value, optional
Possible Values
:
If this optional parameter is not specified, the bytes of a message segment, which are not specified by parameter MSG, will stay undefined.
MBXIDX
mailbox basic index of the task, which shall receive the message (look into DB_M_BASIC_MBX_IDX_SET).
Type of Input
:
Single value, mandatory
Possible Values
:
00 to FF (hex)
MBXNAME
mailbox name of the task, which shall receive the message
Type of Input
:
Single value, mandatory
Possible Values
:
Alphanummeric, 1 to 7 charcters
MSG
Message to receiver task
Message string, hexadecimals.
Background parameter for test step 16.
Type of Input
:
Single value, optional
Possible Values
:
00 to FF (hex); "hh,hh,.....";
The significance of the message string depends on the interpretation by the task.
MSGSIZE
Size of the message segment.
Type of Input
:
Single value, optional
Possible Values
:
00 to FFFF (hex)
If no input for MSGSIZE, then the size of the message segment depents directly from the number of bytes in the message.
PAUSE
Delay in seconds till next message.
Type of Input
:
Single value, optional
Possible Values
:
0 to 60
Standard value
:
0
PROMPT
Test parameter for prompt AMO
Test parameter, requested if necessary in auto-dialog.
Also requested for function 9.
Type of Input
:
Single value, optional
Possible Values
:
0 to 9
UNIT
Functional system unit i.e. SWU or server
Type of Input
:
Single value, mandatory
Possible Values
:
A1
ADS
BP
Base processor active
BPA
Base processor A
BPB
Base processor B
BPS
Base processor stand-by
C1
Call charge server
GP0
Group processor 0 active
GP0A
Group processor 0 A
GP0B
Group processor 0 B
GP0S
Group processor 0 stand-by
.
.
.
.
GP31
Group processor 31 active
GP31A
Group Processor 31 A
GP31B
Group Processor 31 B
GP31S
Group processor 31 stand-by
T1
Tele-Communications Service 1
T2
Tele-Communications Service 2
T3
Tele-Communications Service 3
V1
Voice Mail Service 1
V2
Voice Mail Service 2
V3
Voice Mail Service 3
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.