195.5 Technical Clarification

If an error is detected during tracing, the tracer enters in the trace buffer a data record with an error indication. In the case of the display commands with TYPE=ALL these error indications are visible; they are indicated by the fact that a hexadecimal number is specified as the object type.
first Byte indicates the type of Error
first hexadecimal digit indicates Group of conditions, which is affected
second hexadecimal digit is an Error code
second Byte indicates involved Object type