198.4
Error Messages and Advisories
198.4.1
Error Messages
F01:
PEN ERROR; PERMISSIBLE RANGE FOR LTG: 1-<ltg_max>
F02:
PEN ERROR; PERMISSIBLE RANGE FOR LTU: 1-<ltu_max>
F03:
PEN ERROR; SLOT <sss> FORMALLY INCORRECT
F04:
PEN ERROR; PERMISSIBLE RANGE FOR CIRCUIT NUMBER: 0-<cct_max>
F05:
NO FURTHER TRUNKS CAN BE ASSIGNED IN THE PABX
F06:
LTG <gg> NOT ASSIGNED
F07:
LTU <uu> NOT ASSIGNED
F08:
THE TRUNK WITH PEN <pen> IS ACTIVE
REPEAT COMMAND WITH OFFTYPE=DI OR OFFTYPE=DC
OR DEACTIVATE WITH AMO DSSU
F09:
THE TRUNK WITH PEN <pen> IS CAMP-ON BLOCKED
REPEAT COMMAND LATER OR WITH OFFTYPE=DI
OR DEACTIVATE IMMEDIATELY WITH AMO DSSU
F10:
TRUNK ALREADY ASSIGNED
F11:
TRUNK NOT ASSIGNED
F12:
NO FREE PEN FOUND FOR THIS DEVICE
F13:
REQUIRED MODULE NOT CONFIGURED AT SLOT <sss>
F14:
NO MODULE CONFIGURED AT SLOT <sss>
F15:
THE LAST TRUNK OF A TRUNK GROUP WHICH IS ASSIGNED TO AN ACCESS CODE MAY NOT BE DELETED
F16:
COT (TRUNK PARAMETER) NOT ASSIGNED
F17:
COP (LINE PARAMETER) NOT ASSIGNED
F18:
INSUFFICIENT MEMORY SPACE (AMO DIMSU: PARAMETER <param>)
F20:
<param> <value> NOT ASSIGNED
F22:
THE PARAMETERS OF THE TRUNK TO BE ASSIGNED DO NOT MATCH THE PARAMETERS OF THE OTHER TRUNKS IN THE TRUNK GROUP
F23:
TRUNK GROUP NOT YET ASSIGNED
F24:
TRUNK GROUP ALREADY FULL
(Expand trunk group with AMO BUEND or configure new trunk group with the AMO BUEND and assign the identical route access code with the AMO RICHT)
F25:
TRUNK GROUP CANNOT ACCOMODATE ALL TRUNKS
(Expand trunk group with AMO BUEND or configure new trunk group with the AMO BUEND and assign the identical route access code with the AMO RICHT)
F26:
DEVICE TYPE MAY NOT BE CHANGED
F27:
DEVICE IS NOT PROCESSED BY AMO TSCSU
F28:
BLOCK SEPARATOR (OPTYPE=BLKSEP) ONLY POSSIBLE WITH DTMF SIGNALING
F29:
END-OF-BLOCK (OPTYPE=BLKEND) SIGNAL ONLY POSSIBLE WITH DTMF SIGNALING
F30:
ONLY TWO CCMS MAY BE ASSIGNED IN THE PABX
F31:
A MAXIMUM OF 8 DICTATION SYSTEMS MAY BE ASSIGNED PER TRUNK GROUP
F32:
ONLY 64 RAS DEVICES MAY BE ASSIGNED IN THE PABX
F33:
THE TRUNK GROUP FOR THE TCOM MAY ONLY CONTAIN ONE DEVICE
F34:
PARAMETER MUST BE SPECIFIED
(If no default value for COPNO or COTNO can be assigned, it must be entered.)
F41:
PEN1 MAY NOT BE GREATER THAN PEN2
F43:
PEN NOT SPECIFIED AT THE PHYSICAL MODULE LOCATION
F57:
THE LINE CANNOT BE ADDED;
THE CONTRACTED NUMBER OF FLEX+TDM LINES <number> IS REACHED.
PLEASE USE DISP-CODEW FOR DISPLAY OF THE CONTRACTED FEATURE PACKAGES.
PLEASE CONTACT YOUR SERVICE CENTER IF YOU WISH TO ADD MORE LINES.
F62:
THE TRUNK WITH PEN <pen> DOES NOT BELONG TO TRGRP ^tgrp^
F63:
THE TRUNK WITH PEN @@@@@@@@@@@@ IS BUSY REPEAT COMMAND LATER OR WITH LOCK=DI OR DEACTIVATE IMMEDIATELY WITH AMO DSSU
F99:
THE NUMBER OF VARIABLE FIELDS IN THE MASK ABOVE IS EXCEEDED BY @@@@@.
F100
THE GIVEN ALARM NUMBER IS NOT VALID BECAUSE IT DOES NOT LEAD EITHER TO A LOGICAL ALARM OR THE ALARM TYPE DOES NOT MATCH DIR.