- ’ ALL CC INPUT/OUTPUT CONTROLLERS (IOCC)’
- ’ ALL CC INPUT/OUTPUT CONTROLLERS (IOCC-STANDBY)’
- ’ ALL CC INPUT/OUTPUT CONTROLLERS (IOCSN)’
- ’ ALL CC INPUT/OUTPUT CONTROLLERS (IOCSN-STANDBY)’
- ’ ALL CIRCUITS; ALL TERMINALS’
- ’ ALL CIRCUITS’
- ’ ALL FIRMWARE PROCESSORS’
- ’ ALL LTUS’
- ’ ALL MESSAGE BUFFER UNITS (MBU)’
- ’ ALL MODULES OF LTU’
- ’ ALL SERVERS; INTERROGATE’
- ’ ALL TIMESLOTS OF ALL HIGHWAYS TO ALL LTUS OF ONE LTG’
- ’ ANY CIRCUIT’
- ’ ANY TIMESLOT ON ALL CSN-HWYS BETWEEN 2 LTGS’
- ’ BOARD-HIGHWAYS OF A LTU-SHELF’
- ’ CENTRAL SWITCHING NETWORK (CSN)’
- ’ CLOCK GENERATOR; INTERROGATION’
- ’ CHECK ALIVE TEST ON OPTISET TERMINALS’
- ’ COMMON CONTROL’
- ’ CONNECTION BETWEEN WAML BOARD AND ADP’
- ’ CONF; ALL CELLS OF ALL HIGHWAYS’
- ’ CONF; ANY CELL OF A SPECIFIED HIGHWAY’
- ’ CONF; ANY CELL OF ALL HIGHWAYS’
- ’ CONF; ANY CELL OF ANY HIGHWAY’
- ’ CONF; SPECIFIED CELL OF A SPECIFIED HIGHWAY’
- ’ CONF; STATUS WORD MICROPROCESSOR’
- ’ CONF’
- ’ CROSS CHANNEL; IEC BUS’
- ’ CROSS CHANNEL; INTERROGATION’
- ’ CROSS CHANNEL’
- ’ CSN HIGHWAY (LONG ROUTE); ALL TIME SLOTS’
- ’ CSN HIGHWAY (LONG ROUTE); ANY TIME SLOT’
- ’ DATA COMMUNICATION LINK; INTERROGATION’
- ’ DATA COMMUNICATION LINK’
- ’ DATA PROCESSOR; MULTIBUS TIMEOUT’
- ’ DATA PROCESSOR; STATUS OF PARTNER PROCESSOR’
- ’ DATA PROCESSOR; WATCHDOG COUNTER 0’
- ’ DATA PROCESSOR; WATCHDOG COUNTER 1’
- ’ DATA PROCESSOR’
- ’ DCM AND WORKSTATION SELFTEST’
- ’ DOUBLE DATA COMMUNICATION LINK; INTERROGATION’
- ’ DOUBLE DATA COMMUNICATION LINK’
- ’ FIRMWARE, COMMON CONTROL’
- ’ GSN/MTS IN THE STANDBY PART FOR MTS64-BOARDS’
- ’ INPUT OUTPUT CONTROLLER, GP’
- ’ INPUT OUTPUT CONTROLLER, GP’
- ’ INTERFACE PROCESSOR; INTERROGATION’
- ’ INTERFACE PROCESSOR’
- ’ INTERROGATE ALL CC INPUT/OUTPUT CONTROLLERS (IOCC)’
- ’ INTERROGATE ALL CC INPUT/OUTPUT CONTROLLERS (IOCC-ACTIV)’
- ’ INTERROGATE ALL CC INPUT/OUTPUT CONTROLLERS (IOCSN)’
- ’ INTERROGATE ALL CC INPUT/OUTPUT CONTROLLERS (IOCSN-ACTIV)’
- ’ INTERROGATE ALL MESSAGE BUFFER UNITS (MBU)’
- ’ INTERROGATE GP INPUT/OUTPUT CONTROLLER’
- ’ INTERROGATE GP INPUT/OUTPUT CONTROLLER’
- ’ INTERROGATE READY LINE OF PARTNER DATA PROCESSOR’
- ’ LINE CIRCUIT MODULE; STATUS WORD MICROPROCESSOR’
- ’ LINE CIRCUIT MODULE’
- ’ LINEPOWER TEST ON OPTISET TERMINALS’
- ’ LINE TEST BETWEEN SLMA BOARD AND SUBSCRIBER’
- ’ LTG’
- ’ LTU SPEECH HIGHWAYS; ANY TIME SLOT’
- ’ LTU; STATUS WORD MICROPROCESSOR’
- ’ LTU’
- ’ MEMORY; INTERROGATE 1-BIT ERROR DETECTION’
- ’ MEMORY; READING ALL CELLS’
- ’ MEMORY; READING ANY CELL’
- ’ MEMORY; RELEASE WRITE PROTECT MONITOR’
- ’ MEMORY; RELEASE 1-BIT ERROR’
- ’ MEMORY; RELEASE 2-BIT ERROR’
- ’ MEMORY: READ SPECIFIED CELL’
- ’ MEMORY’
- ’ MEMORYTEST’
- ’ MTS-64; READ TS ON ALL MTS-MODULES’
- ’ MULTIBUS’
- ’ PERIPHERAL SIU; LOOP ALL TRANSMITTERS TO ALL RECEIVERS’
- ’ PERIPHERAL SIU; LOOP ANY TRANSMITTER TO SPECIFIED RECEIVER’
- ’ PERIPHERAL SIU; LOOP SPECIFIED TRANSMITTER TO ANY RECEIVER’
- ’ PERIPHERAL SIU; LOOP SPECIFIED TRANSMITTER TO SPECIFIED RECEIVER’
- ’ PERIPHERAL SIU; MICROPROCESSOR STATUS WORD’
- ’ PERIPHERAL SIU’
- ’ PERIPHERY’
- ’ PHONE SELFTEST’
- ’ SCC DATA COMMUNICATION LINK; INTERROGATION’
- ’ SCC DATA COMMUNICATION LINK’
- ’ SCC-SIUCO MICROPROCESSORTEST’
- ’ SCC-SIUCO; ALL CELLS OF ALL HIGHWAYS’
- ’ SCC-SIUCO; ANY CELL OF A SPECIFIED HIGHWAY’
- ’ SCC-SIUCO; ANY CELL OF ALL HIGHWAYS’
- ’ SCC-SIUCO; ANY CELL OF ANY HIGHWAY’
- ’ SCC-SIUCO; ANY TRANSMITTER, ALL RECEIVERS’
- ’ SCC-SIUCO; ANY TRANSMITTER, SPECIFIED RECEIVER’
- ’ SCC-SIUCO; CONTINUANCE TONE TO ANY RECEIVER’
- ’ SCC-SIUCO; CONTINUANCE TONE TO SPECIFIED RECEIVER’
- ’ SCC-SIUCO; LOOP BACK TEST TRANSMITTER TO ANY RECEIVER’
- ’ SCC-SIUCO; LOOP BACK TEST TRANSMITTERS TO SPECIFIED RECEIVER’
- ’ SCC-SIUCO; LOOP CADENCED TONE TO ANY RECEIVER’
- ’ SCC-SIUCO; LOOP CADENCED TONE TO SPECIFIED RECEIVER’
- ’ SCC-SIUCO; LOOP SPECIFIC DIAL TONE TO ANY RECEIVER’
- ’ SCC-SIUCO; SPECIFIED CELL OF A SPECIFIED HIGHWAY’
- ’ SCC-SIUCO; SPECIFIED TRANSMITTER, SPECIFIED RECEIVER’
- ’ SCC-SIUCO; STATUS WORD MICROPROCESSOR’
- ’ SCC-SIUCO; STATUS WORD MICROPROCESSOR’
- ’ SCC-SIUCO’
- ’ SERVICE UNIT OF ONE LTG’
- ’ SIU; ANY TRANSMITTER, ALL RECEIVERS’
- ’ SIU; ANY TRANSMITTER, SPECIFIED RECEIVER’
- ’ SIU; CONTINUANCE TONE TO ANY RECEIVER’
- ’ SIU; CONTINUANCE TONE TO SPECIFIED RECEIVER’
- ’ SIU; LOOP BACK TEST TRANSMITTER TO ANY RECEIVER’
- ’ SIU; LOOP BACK TEST TRANSMITTERS TO SPECIFIED RECEIVER’
- ’ SIU; LOOP CADENCED TONE TO ANY RECEIVER’
- ’ SIU; LOOP CADENCED TONE TO SPECIFIED RECEIVERS’
- ’ SIU; LOOP SPECIFIC DIAL TONE TO ANY RECEIVER’
- ’ SIU; SPECIFIED TRANSMITTER, SPECIFIED RECEIVER’
- ’ SIU; STATUS WORD MICROPROCESSOR’
- ’ SIU/CONF-MICROPROCESSORTEST’
- ’ SIUCO; ALL CELLS OF ALL HIGHWAYS’
- ’ SIUCO; ANY CELL OF A SPECIFIED HIGHWAY’
- ’ SIUCO; ANY CELL OF ALL HIGHWAYS’
- ’ SIUCO; ANY CELL OF ANY HIGHWAY’
- ’ SIUCO; ANY TRANSMITTER, ALL RECEIVERS’
- ’ SIUCO; ANY TRANSMITTER, SPECIFIED RECEIVER’
- ’ SIUCO; CONTINUANCE TONE TO ANY RECEIVER’
- ’ SIUCO; CONTINUANCE TONE TO SPECIFIED RECEIVER’
- ’ SIUCO; LOOP BACK TEST TRANSMITTER TO ANY RECEIVER’
- ’ SIUCO; LOOP BACK TEST TRANSMITTERS TO SPECIFIED RECEIVER’
- ’ SIUCO; LOOP CADENCED TONE TO ANY RECEIVER’
- ’ SIUCO; LOOP CADENCED TONE TO SPECIFIED RECEIVER’
- ’ SIUCO; LOOP SPECIFIC DIAL TONE TO ANY RECEIVER’
- ’ SIUCO; SPECIFIED CELL OF A SPECIFIED HIGHWAY’
- ’ SIUCO; SPECIFIED TRANSMITTER, SPECIFIED RECEIVER’
- ’ SIUCO; STATUS WORD MICROPROCESSOR’
- ’ SIUCO-MICROPROCESSORTEST’
- ’ SIUCO’
- ’ SPECIFIED CIRCUIT; ALL TERMINALS’
- ’ SPECIFIED CIRCUIT; SPECIFIED TERMINAL’
- ’ SPECIFIED CIRCUIT’
- ’ SPECIFIED LTU’
- ’ SPECIFIED PCM-HWY’
- ’ SPECIFIED SERVER; INTERROGATE’
- ’ SPEECH HIGHWAYS; ALL TIME SLOTS’
- ’ SPEECH HIGHWAYS; ANY TIME SLOT’
- ’ SPEECH HIGHWAYS; SPECIFIED TIME SLOT’
- ’ STANDARD SCC-SIUCO’
- ’ STANDARD SIU’
- ’ STANDARD SIUCO’
- ’ SWITCHING NETWORK; READ ALL CONTROL MEMORY CELLS’
- ’ SWITCHING NETWORK; READ ANY CONTROL MEMORY CELL’
- ’ SWITCHING NETWORK; READ SPECIFIED CONTROL MEMORY CELL’
- ’ SWITCHING UNIT’
- ’ T1 MODULE’
- ’ THE RESET OF THE ATTENUATION HAS BEEN INITATED BY RTO’
- ’ THE TIMESLOT HAS BEEN SWITCHED OFF BY RTO’
SIU: LTG = aa LTU = b SLOT = ccc
TRANSMITTER: LTG = aa LTU = b SLOT = ccc FUNCTION = d
RECEIVER: LTG = aa LTU = b SLOT = ccc FUNCTION = d
TIMESLOT-INDEX = ee
STATUS : fffff / fffff / fffff / fffff / fffff
Value abbreviations: aa LTG Number 1-32
b LTU Number 1-99
ccc Slot 1-151
d SIU function 0-3
ee Timeslot 0-255
fffff Status
The status of the testobject will be displayed at test result
’ADVISORY: CANNOT BE TESTED BECAUSE OF BASIC STATUS’
Values for status are
NOGEN, AMO, LOCK, HIRAMO, SOFTLOCK, READY, UNACH,
UNACA, DEFECT, NPR, WBT, NL, TRS, WAIT, DEP, CP, CPH
TEST : Detailed test job which led to negative result.
ERROR : Test result
OBJECT : Test object (LTG, LTU and PBC number)
TRANSMITTER : Tone transmitter used for echoplexing
RECEIVER : Tone receiver used for echoplexing
CSN : Central switching network
LTG : Line/Trunk Group (1-32)
LTU : Line/Trunk Unit (1-99)
PBC : Peripheral Board Controller number (1-25)
SLOT : Slot (1-151)
FUNCTION : SIU funktion (0-3)
MTS : Memory time switch (1-7)
HWY : Highway number (0-127)
TIMESLOT : Timeslot (0-31)
CIRCUIT : Line circuit number (0-63)
B-CHANNEL : B-channel (0, B, B’)
MODULE TYPE : Line circuit module (SLMA, SLMD, OLMD, TMDE, TMBD...?)
STATUS : Status (0-255)
TS INDEX : Timeslot index (0-255)
LOOPB : Test loop (2A, 2B, 2C, 4, 5, 6)
QUANTITY : Number of 1-bit errors which occured (0-1023)
ADDRESS : Memory address (0-255 / 0-65535)
TONE : Numerical value of TONE power set (int.dial tone, busy tone,.?)
PROCESSOR : Processor (system unit) name (ADS, CM, VM1, TF1,...?)
TSI : Terminal selection identifier (1-8)