Error Messages and Advisories
199.5.1
Error Messages
F01:
TEST IN PROGRESS - FURTHER START NOT PERMISSIBLE
(Any new test job may only be started when the test in progress has been terminated internally or aborted by the operator.)
F02:
TEST NOT POSSBILE AT THE MOMENT
F03:
TEST HAS BEEN INTERRUPTED
F04:
LTG NOT ASSIGNED
F05:
LTG NOT PRESENT
F06:
LTG NUMBER DOES NOT HAVE ADMISSIBLE VALUE; MAXIMUM LTG NUMBER: <number>
F07:
LTU NOT ASSIGNED OR LOCKED
F08:
LTU NOT PRESENT
F09:
LTU NUMBER DOES NOT HAVE ADMISSIBLE VALUE; MAXIMUM LTU NUMBER: <number>
F10:
MODULE NOT ASSIGNED (NOGEN)
F11:
MODULE NOT PRESENT (NPR)
F12:
MODULE HIERARCHICALLY LOCKED (UNACH)
F13:
MODULE TYPE <brdtype> CANNOT BE TESTED
F14:
WRONG MODULE TYPE (WBT)
F15:
LOOP NOT ALLOWED FOR THIS MODULE TYPE
F16:
NO RESPONSE FROM RTO
F17:
TEST IS NOT POSSIBLE FOR THIS SYSTEM VARIANT
F18:
CIRCUIT NUMBER DOES NOT HAVE ADMISSIBLE VALUE; MAXIMUM CIRCUIT NUMBER: <number>
F19:
MODULE HAS NOT LINE CIRCUITS
F20:
DESTINATION PROCESSOR NOT AVAILABLE
F21:
WRONG SLOT OR MODULE NOT PRESENT
F22:
NO STATION HAS BEEN CONFIGURED WITH THIS DATA
F23:
LOOP TEST ONLY VALID FOR CORNET-T TERMINALS OR OPTISET-TERMINALS
F24:
PCMLINE TEST NOT ALLOWED FOR <board-type>
F25:
SELFTEST NOT ALLOWED FOR <board-type>
F26:
LTG1 NOT ASSIGNED
F27:
LTG1 NOT PRESENT
F28:
LTG2 NOT ASSIGNED
F29:
LTG2 NOT PRESENT
F30:
LTG1 AND LTG2 ARE EQUAL
F31:
WORKSTATION NOT ASSIGNED
F32:
BOARD NOT LOADED (NL)
F33:
CIRCUIT NOT CONFIGURED
F34:
STATION WITHOUT PHYSICAL DEVICE
F35:
STATION NOT CONFIGURED FOR THIS NUMBER AND THIS SERVICE
F36:
TEST IN PROGRESS - FURTHER START NOT POSSIBLE !
F37:
AT TMD/T1 BOARDS ONLY CIRCUIT = 1 IS ALLOWED
F38:
TEST IS ONLY POSSIBLE AT AN OPTISET E TERMINAL
F39:
TEST IS ONLY POSSIBLE AT AN OPTISET MASTER TERMINAL
F40:
CIRCUIT TEST NOT POSSIBLE ON THIS BOARD
F41:
NO TERMINAL IS ASSIGNED TO THIS STATION NUMBER
F42:
TERMINAL IS SIGNED OFF AND THEREFORE IT CANNOT BE TESTED
F43:
IN THIS SLOT THERE IS NO WAML BOARD !
F44:
TEST ALLOWED ON DIUS2, DIUS7, DIUN2, DIUN4 OR SLMN-E1 ONLY !
F45:
ONLY MDL TEST IS POSSIBLE ON THIS CARD.
NO CIRCUIT TESTS OR DEVICE (TERMINAL) TESTS ARE ALLOWED.
F46:
TEST OF NAILED CONNECTIONS NOT ALLOWED
F47:
TEST OF LOCAL LOOP (ILOC) ON BOARD SLMN-T1 : THE FIRST 24 CIRCUITS OF A SPAN (1 - 24, 26 - 49, 51 - 74 OR 76 - 99) MUST BE TAKEN OUT OF SERVICE VIA AMO DSSU AND THE LAST CIRCUIT OF A SPAN VIA AMO BSSU ! AMO TSU EXPECTS THE NUMBER OF THE SPAN (1,2,3 OR 4) AS INPUT OF PARAMETER ’CIRCUIT’
F48:
TEST OF REMOTE LOOP (IDC OR EDC) ON BOARD SLMN-T1 : THE LAST CIRCUIT OF A SPAN (25, 50, 75 OR 100) MUST BE IN SERVICE, BUT THE OTHER CIRCUITS (1 -24, 26 - 49, 51 -74, 76 -99) MUST BE BLOCKED VIA AMO DSSU ! AMO TSU EXPECTS THE NUMBER OF THE SPAN (1,2,3 OR 4) AS INPUT OF PARAMETER ’CIRCUIT’
F49:
TEST OF TERMINALS CONNECTED TO SLMO-ROUTING BOARD NOT POSSIBLE
F50:
THIS TEST IS ONLY POSSIBLE IN SUBSCRIBER STATE ’OFFHOOK’. THIS DOES NOT CORRESPOND TO THE CALL PROCESSING STATE AT THE MOMENT. THE TEST CAN BE CARRIED OUT, WHEN THE LINE IS TAKEN OUT OF OPERATION BY CALLING AMO DSSU. AFTER THE TEST THE LINE MUST BE TAKEN BACK TO OPERATION !
F51:
THIS TEST IS ONLY POSSIBLE IN SUBSCRIBER STATE ’ONHOOK’ (THIS DOES NOT CORRESPOND TO THE CALL PROCESSING STATE ’IDLE’). AT THE MOMENT THE SUBSCRIBER IS NOT IN STATE ’IDLE’. THE TEST CAN BE CARRIED OUT, WHEN THE LINE IS TAKEN OUT OF OPERATION BY CALLING AMO DSSU. AFTER THE TEST THE LINE MUST BE TAKEN BACK TO OPERATION !
F52:
SUBSCRIBER IS IN STATE ’CONNECTED’. THE TEST CAN ONLY BE STARTED WHEN THE LINE IS TAKEN OUT OF OPERATION BY CALL OF AMO DSSU. AFTER THE TEST THE LINE MUST BE TAKEN BACK TO OPERATION !
F53:
LINETEST IS ONLY POSSIBLE ON SLMA BOARD TYPES Q2141, Q2157, Q2246, ON SLMAR BOARD Q2480-X000 AND ON SLMA3 BOARD Q2191-X
F54:
LINETEST CAN NOT BE CARRIED OUT, BECAUSE NECESSARY SIUX BOARD (Q2233-X, FUNCTION ID 7) IS NOT AVAILABLE IN THE SWITCH
F55:
ON STMA CARD DEVICE (TERMINAL) TEST IS POSSIBLE ONLY IN OPERATION MODES ’TFA’ OR ’PSW’
F56:
ON DSC80 CARD CONF, MDL AND HIGHWAY TESTS ARE NOT POSSIBLE.
F57:
TMDN DIAGNOSTIC TESTS ARE NOT POSSIBLE OVER CORNET-N TRUNK LINKS TO GENERIC SERVER.
F58:
ONLY SELFTEST VALID FOR WORKSTATIONS, ROLMPHONES OR DCM (DATA COMMUNICATION MODULE).
F59:
HIGHWAY NOT ASSIGNED TO THIS BOARD
F60:
LOOP 4 TEST NOT POSSIBLE ON ANALOG TERMINAL ADAPTER.
F61:
TEST OF LTU 1 ON 80CMX-DSC AND 40CMX-DSC SWITCHES IS NOT POSSIBLE .
F62:
PCMLINE <number> NOT ALLOWED FOR <boardtype>
F63:
TEST IS ONLY ALLOWED ON LTUC BOARDS WITH CENTRAL BYTE MANIPULATION MODULES
F64:
AP NOT ASSIGNED OR LOCKED
F65:
AP NOT PRESENT
F66:
THIS FUNCTION IS NOT ALLOWED FOR SOFTGATE SHELVES.