202.3
Parameter Description
ALARMNO
Alarm number
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
0, 8 to 519
Default Value
:
0
APDATA
AP Data
Type of Input
:
Single value, optional (DISPLAY)
Possible Values
:
GEN
General Data
TONES
Tone Table
APRTADDR
AP gateway IP address (i.e 20.1.2.129)
Type of Input
:
1 to 4 single values, concatenated with "."
optional (ADD, CHANGE)
Possible Values
:
0 to 255
BCHLCNT
Amount of b-channels on NCUI board
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
1 - 30
Default Value
:
30
CNTRYCD
Loadware variant for SLMA2 / SLMAR
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
0
Germany (DB-Initialization)
1
Austria
10
Hungary
11
India
12
Oman
13
GUS (Russia, Ukraine, Belorussia,Georgia
14
Cameroon
15
Israel
16
South Korea
17
Turkey
18
Japan
19
Vietnam
2
Switzerland
20
Kenya
21
Zimbabwe
23
Algeria
24
Nigeria
25
Congo
26
Ethiopia
27
Burundi
28
Pakistan
29
Yugoslavia
3
Belgium
4
Australia
5
Spain
6
Republic South Africa
7
Great Britain, Ireland
8
Finland
9
Portugal
A
France
B
Netherlands
C
China, Tanzania
D
Italy
E
Malaysia
F
Poland
G
Mexico
H
Denmark
I
Argentina
J
Czech Republic
K
USA
L
Luxembourg
M
Singapore
N
Indonisia
O
Thailand
P
Philippines
Q
Brazil
R
Greece
S
Hongkong
T
Morocco
U
Sweden
V
DSN - A-law coding
W
DSN - U-law coding
CONNTYPE
Connection type of the LTU shelf
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
LOCAL
local LTU
FLEX
via Fiber Link connected LTU
APDL
AP shelf via IP - direct linked
APNW
AP shelf via IP - network
Default Value
:
LOCAL
only for HHS shelves
CONVLAW
Convertion from A-Law to Mu-Law on NCUIx board (
in advance)
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
YES, NO
Default Value
:
YES
CP
Call processing tone
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
ALERT
Notification/alert tone
ANNICPT
Announcement for attendant intercept
BONHK
B-party on hook (for US only)
BRKMSGWT
Broken dial tone when message waiting
BUSY
Busy tone
CAMP
Camp-on tone
CAMPBRK
Ringback tone when camped on
CBKALERT
Callback alert tone
CCMABSEN
CCM tracer in rack
CMALTONE
Call monitoring alerting tone
CONFDISC
Conference disconnect tone
CONFTN
Conference tone
CONG
Congestion tone
DATA
Data tone
DISCTONE
Disconnect tone
DND
Do not disturb tone
EXTDTN
External Dial tone
EXTDTN2
Secondary co dial tone
FCAMP
first camp-on tone
FRNGBK
First burst of ringback tone
HOLD
Hold tone
HOLDCCS
Hold tone code calling system (ccs)
HOLDEXT
Hold tone external
HOLDH1
Hold tone hold 1
HOLDH2
Hold tone hold 2
HOLDHUNT
Hold tone hunting-group
HOLDINT
Hold tone internal
HOLDLINE
Hold the line please
HOWLTONE
Howltone after busytone timeout
HUNTGRUP
Announcement huntgroup queue
IMPOSSFM
Impossible for the moment
INTDTN
Internal dial tone
KNCONF
Camp-on tone for conference
LCRET
LCR Expensive route tone
LOCANN
Local announcement
MOH
Music on hold
MWI
Message waiting indication
NACK
Negative acknowledgement tone
NODIAL
Timeout tone if digits not dialed
NOPO
Not possible
NOTALWD
Not allowed
NOTREACH
Not reachable
NU
Number unobtainable tone
OFFHKTRQ
Off hook trunk queueing
OVR
Automatic override tone
OVRTN
Override tone
OVRWARN
Override warning tone
PACK
Positive acknowledgement tone
PACKWD
Positive acknowledge tone with dialing
POSTDIAL
Announcement post dial
RECDIALT
Recall dial tone
REORDER
Reorder tone (includes BONHK-Tone outside US)
REQDIALT
Request Dial Tone
RNGBK
Ringback tone
ROUTTONE
SCNF France: Connect routing tone
RTCHKNTF
LCR route check not finished
RTOTON1
Test for first tone receiver group
RTOTON2
Test for second tone receiver group
SECDIALT
Second Dial Tone
SPEC
Special Dial Tone
TEST
Test tone
VOICEMAL
Voice mail
ZIPTONE
Alerttone for acd-g automatic connection
DHCPV4
DHCP version 4
Type of Input
:
single value, optional (ADD)
Possible Values
:
YES, NO
DHCPV6
DHCP version 6
Type of Input
:
single value, optional (ADD)
Possible Values
:
YES, NO
DTR
Selection of country-specific dial tone receiver table
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
0
Germany (DB-Initialization)
1
Austria
10
Hungary
12
Oman
13
GUS
14
Cameroon
15
Israel
16
South Korea
17
Turkey
18
Japan
19
Vietnam
2
Switzerland
20
Kenya
21
Zimbabwe
23
Algeria
24
Nigeria
25
Congo
26
Ethiopia
27
Burundi
28
Pakistan
29
Yugoslavia
3
Belgium
4
Australia
5
Spain
6
South Africa
7
Great Britain, Ireland
8
Finland
9
Portugal, Brazil
A
France
B
Netherlands
C
China, Tanzania
D
Italy
E
Malaysia
F
Poland
G
Mexico
H
Denmark
J
Czech Republic
K
USA
M
Singapore
N
Indonisia
O
Thailand
P
Philippines
Q
Brazil
R
Greece
S
Hongkong
T
Morocco
U
Sweden
FAX
Fax number at the shelf location
Type of Input
:
up to 22 digits, optional (ADD, CHANGE)
Possible Values
:
0 - 9, *, #, A - D, up to 22 characters
ENTGW
LOCAL SYSTEM SHELF
Type of Input
single value, optional
FRMTYPE
Type of LTU frame
Type of Input
:
Single value, mandatory (ADD, CHANGE)
Possible Values
:
AP370013
SAPP frame for 600cpci shelves
AP37009
SAPP frame for ENTGW shelves
INCH19
19 inch frame for AP shelves
L80XF
for 600cpci and AP shelves
LTUW
frame for 600ecx and AP shelves
SOCOAP
Virtual AP37009 frame for softgate AP shelves
IPMODE
IP Mode
Type of Input
:
single value, optional (ADD)
Possible Values
:
DUALSTCK
IP version 4 and IP version 6
IPV4
IP version 4
LANGID
LANGUAGE ID FOR OPTISET
Type of Input
:
1 to 5 single values, concatenated with &, optional
Possible Values
:
DUTCH
dutch
ENGLISH
english
FRENCH
french
GERMAN
german
GREEK
greek
ITALIAN
italian
PICTO
pictogram
PORTUG
portuguese
RES1
Reserve 1
RES2
Reserve 2
RES3
Reserve 3
RES4
Reserve 4
RES5
Reserve 5
RES6
Reserve 6
SPANISCH
spanish
LOCATION
postal adress of the LTU shelf
Type of Input
:
Single value, optional (ADD, CHANGE - UNIT = LTU)
:
Single value, mandatory (ADD, CHANGE - UNIT = AP)
Possible Values
:
Text string with max. 45 alphanumerical characters
Default Value
:
45 blanks
LOCID
Location ID of LTU
Type of Input
:
Single value, optional (ADD, CHANGE - UNIT = LTU)
:
Single value, mandatory (ADD, CHANGE - UNIT = AP)
Possible Values
:
0 - 999
LSRTADDR
IP address (i.e 198.16.16.78) of primary signalling router for NCUI board
Type of Input
:
1 to 4 single values, concatenated with "."
:
optional (ADD, CHANGE)
Possible Values
:
0 to 255
LTG
Specification of the LTG
Type of Input
:
Single value, optional
Single value or area, optional (DISPLAY, REGENERATE)
mandatory (ADD, DELETE)
Possible Values
:
1 - 1
Default Value
:
1
LTPARTNO
Partnumber of adding LTUC module.
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
Text string with max. 10 alphanumerical characters
LTU
Specification of the LTU in an LTG. The LTU shelves (module frames for line units) are numbered consecutively in the cabinet from top to bottom.
Type of Input
:
Single value or area, optional (DISPLAY, REGENERATE)
mandatory (ADD, DELETE)
Possible Values
:
1 to LTU number max for UNIT = LTU
:
17 to 99 for UNIT = AP (gap between LTU number max and 17 depends on the HW platform)
PHONE
Phone number at the shelf location
Type of Input
:
up to 22 digits, optional (ADD, CHANGE)
Possible Values
:
0 - 9, *, #, A - D, max 22 characters
PLCHECK
check payload quality matrix
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
YES, NO
Default Value
:
YES
REGDEF
regenerate also default values of tone table
Type of Input
:
single value, optional (REG)
Possible Values
:
YES, NO
Default Value
:
NO
SRCGRP
SOURCE GROUP INDEX
Type of Input
single value, mandatory
Possible Values
numeric, 1-255
SIGMODE
signaling mode
Type of Input
:
single value, optional
Possible Values
:
HSRTCP
HSR over TCP
HSRUDP
HSR over UDP
SIPARTNO
Specification of the central SIU module for each LTG
Type of Input
:
single value, mandatory (ADD)
Possible Values
:
text, up to 10 characters
SIU
Assigned siu tones. Countryspecific meanings are listed in Service Handbook in country chapters.
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
numeric, 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26
SIUANN
Set options for SIU announcement texts (no AC). Enter loadware variant into DB. (Reload of SIU data for AP shelves by means of EXEC-USSU:NCUILOAD;)
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
1
Germany (DB-Initialization)
2
English
3
French
4
Spanish
5
Portuguese
6
Dutch
7
Danish
8
Finnish
9
Portuguese (Brazil)
A
Italian
C
Chinese
C
chinese
D
American-English
E
Hungarian
F
Polish
H
Russian(CIS)
N
Greek
SIUC
Selection of country specific SIU tone table
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
0
Germany (DB-Initialization)
1
Austria
10
Hungary
12
Oman
13
GUS
14
Cameroon
15
Israel
16
South Korea
17
Turkey
18
Japan
19
Vietnam
2
Switzerland
20
Kenya
21
Zimbabwe
23
Algeria
24
Nigeria
25
Congo
26
Ethiopia
27
Burundi
28
Pakistan
29
Yugoslavia
3
Belgium
4
Australia
5
Spain
6
South Africa
7
Great Britain, Ireland
8
Finland
9
Portugal, Brazil
A
France
B
Netherlands
C
China, Tanzania
D
Italy
E
Malaysia
F
Poland
G
Mexico
H
Denmark
J
Czech Republic
K
USA
L
Luxembourg
M
Singapore
N
Indonisia
O
Thailand
P
Philippines
Q
Brazil
R
Greece
S
Hongkong
T
Morocco
U
Sweden
V
DSN - A-law coding
W
DSN - U-law coding
SOCOTYPE
SoftGate config type
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
SOCO50
SoftGate with BCSU 50 STN port check
SOCO1000
SoftGate with BCSU 1000 STN port check
SOCO500
NO LONGER USED
SRCGRP
Source group index
Type of Input
:
1 to 2 single values, concatenated with "&"
optional (DISPLAY / CHANGE)
Singe value, mandatory (ADD)
Possible Values
:
1 - 99
TCLASS
Time class index
Type of Input
:
Single value, optional (ADD, CHANGE -UNIT = AP)
Possible Values
:
0 to 50
Default Value
:
0
TEXTSEL
AP settings for individual language setting of display texts.
Type of Input
:
1 to 5 single values, concatenated with &, optional
Possible Values
:
AMERICAN
american english
BRAZIL
brazil
CATALAN
catalan
CHINESE
chinese
CROATIAN
croatian
CZECH
czech
DANISH
danish
DUTCH
dutch
ENGLISH
english
ESTON
estonian
FINNISH
finnish
FRENCH
french
GERMAN
german
GERNOUML
german without umlauts
GREEK
greek
HUNGARY
hungarian
INDONES
indonesian
ITALIAN
italian
JPN
japanese
KOREAN
korean
LATVIAN
latvian
LITHUAN
lithuanian
MALAY
malayan
NORWEG
norwegian
POLISH
polish
PORTUG
portuguese
ROMANIAN
romanian
RUSSCYR
russian (cyrillic letters)
RUSSLAT
russian (latin letters)
SERBCYR
serbian (cyrillic letters)
SERBLAT
serbian (latin letters)
SLOVAK
slovakian
SLOVEN
slovenian
SPANISH
spanish
SWEDISH
swedish
THAI
thai
TURKISH
turkish
UNIT
Type of unit to be processed
Type of Input
:
Single value, optional (DISPLAY, REGENERATE)
mandatory (ADD, CHANGE, DELETE)
Possible Values
:
LTG
= LINE/TRUNK GROUP
The LTG unit without its LTU and peripheral module configuration is processed. In duplex-systems, LTG halves A and B are processed.
LTPARTNO
PARTNUMBER OF ADDING LTUC/NCUI MODULE
LTU
= LINE/TRUNK UNIT
LSRTADDR
AP PRIMARY ROUTER IP ADDRESS IN LS NET
The LTU without its configuration of peripheral modules is processed.
AP
= LINE/TRUNK UNIT access point for NBCS
APRTADDR
IP ADDRESS OF AP FIRST-HOP ROUTER
The LTU without its configuration of peripheral modules is processed.
PARTNO
= cat. number (CHANGE)
Change PARTNO of central SIU.
SIPARTNO
CAT. NUMBER OF SIU/RTM FROM PART CATALOG
SRCGRP
(DISPLAY)
Default Value
:
LTU
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.