203.3.2
CHANGE-UPDAT
This function is used
•
to set the twelve times for automatic update,
•
to activate or deactivate the automatic update.
Note
•
The cross signaling of data changes (if duplex) cannot be deactivated.
•
The status and times of the automatic update are stored as data in the database itself so that any change will only be permanent after an automatic or manual update has been performed.
•
The automatic update times for the various HW modules should not coincide, or else there will be a HD backup queue.
•
If the automatic update is to be performed less than 12 times per day, the same update time should be entered several times (see Example).
Procedure Overview
Command Code
Parameter
CHANGE-UPDAT
UNIT=<param>,{STATE=<param>
,UPDT01=<St-Mi>,....,UPDT12=<St-Mi>};
Examples
1.
Setting the update times in the SWU to 03:30 and 13:30 (twice a day).
Input:
CHANGE-UPDAT:BP,,03-30,13-30,13-30,13-30,13-30,13-30,
13-30,13-30,13-30,13-30,13-30,13-30;
2.
Activating the automatic hard disk update in the SWU.
Input:
CHANGE-UPDAT:BP,ON;