207.5.4
DEACTIVATE-VADSU
Deactivate a not active alarm. All alarms can be deactivated, even those, whose thresholds can not be changed.
When threshold values can be changed, an alarm can also be deactivated using ’CHANGE-VADSU’.
Procedure Overview
Command Code
Parameter
DEACTIVATE-VADSU
[ALARMGR=CENTRAL,ALARMNO=<range>;
|ALARMGR=PERIPHER,ALARMNO=<range>;
|ALARMGR=LOGICAL,ALARMNO=<range>;;
|ALARMGR=SNAPSHOT;
Examples
1.
Deactivate a central alarm:
Input:
DEACT-VADSU:CENTRAL,5;
Output:
H500: AMO VADSU STARTED
H02: MINOR ALARM 5 HAS BEEN DEACTIVATED.
H03: MAJOR ALARM 5 HAS BEEN DEACTIVATED.
AMO-VADSU-69 NMC ALARMS CONFIGURATION, SWITCHING UNIT
DEACTIVATE COMPLETED;
2.
Activate the SNAPSHOT function
Input:
DEACT-VADSU:SNAPSHOT;
Output:
H500: AMO VADSU STARTED
AMO-VADSU-69 NMC ALARMS CONFIGURATION, SWITCHING UNIT
DEACTIVATE COMPLETED;