214.4.4
DEACTIVATE-VOICO
This command is used to deactivate the activated VC connections.
Mind following steps:
–
Both circuits (VCM and partner board) have to be deactivated.
–
The VC connection of the specified VCSU has to be configuried and activated.
–
The VC connection VCSU1 has to be deactivated last.
Procedure Overview
Command Code
Parameter
DEACTIVATE-VOICO
PEN1=<pen>,[VCSU=<number>];
Examples
1.
Deactivate a VC connection with VCSU2 for VCM pen: 1-1-49-0.
Input:
DEACT-VOICO:1-1-49-0,2;
2.
Deactivate all activated VC connections for VCM pen: 1-1-49-0.
Input:
DEACT-VOICO:1-1-49-0;