Collapse AllExpand All

2.2.5.4. Required Bandwidth per Connection Previous topic Parent topic Child topic Next topic

Note that the bandwidth calculation is based on 70 bytes of overhead: RTP (12 bytes), UDP (8 bytes), IP (20 bytes), 802.1Q VLAN Tagging (4 Bytes), MAC (incl. Preamble, FCS, 26 Bytes).
IMPORTANT:
Bandwidth requirements assume Full Duplex operation! When running Half Duplex, twice the bandwidth is required.
Bandwidth for active DMC master connections without SPE:

Table 5. Bandwidth for active DMC master connections without SPE

Codec
Sampling Time [ms]
Payload Frames per second
Payload [Bytes]
Total Bytes
Bandwidth [Bit/s]
G.711
10
100,00
80
150
120000
 
20
50,00
160
230
92000
 
30
33,33
240
310
82667
 
40
25,00
320
390
78000
 
G.729AB
20
50
20
90
36000
 
30
33,33
30
100
26667
 
40
25,00
40
110
22000
 
60
16,67
60
130
17333
 
G.723
30
33.33
24
94
25067
 
60
16,67
48
118
15733
Bandwidth for active DMC master connections with SPE:

Table 6. Bandwidth for active DMC master connections with SPE

Codec
Sampling Time [ms]
Payload Frames per second
Payload [Bytes]
Total Bytes
Bandwidth [Bit/s]
G.711
10
100,00
90
160
128000
 
20
50
170
240
96000
 
30
33,33
250
320
85333
 
40
25,00
330
400
80000
 
G.729AB
20
50
30
100
40000
 
30
33,33
40
110
29333
 
40
25,00
50
120
24000
 
60
16,67
70
140
18667
 
G.723
30
33.33
34
104
27733
 
60
16,67
58
128
17067
Bandwidth for master connections no longer used (without SPE):

Table 7. Bandwidth for master connections no longer used (without SPE)

Codec
Frame
Packets
Packet Size [Byte]
Bandwidth [kBit/s]
SID(1) relative to Active
Length [Byte]
Length
Rate
Pure Data
Ethernet
Ethernet
Ethernet
G.711
1
1000 ms
1,00 /s
1
71
0,6
0,7%
G.729A
2
1000 ms
1,00 /s
2
72
0,6
1,6%
G.723
4
990 ms
1,01/s
4
74
0,6
2,4%
Bandwidth for master connections no longer used (with SPE):

Table 8. Bandwidth for master connections no longer used (with SPE)

Codec
Frame
Packets
Packet Size [Byte]
Bandwidth [kBit/s]
SID(2) relative to Active
Length [Byte]
Length
Rate
Pure Data
Ethernet
Ethernet
Ethernet
G.711
1
1000 ms
1,00 /s
11
81
0,6
0,8%
G.729A
2
1000 ms
1,00 /s
12
82
0,7
1,6%
G.723
4
990 ms
1,01/s
14
84
0,7
2,4%

 (1) rate between active master connections and master connections no longer used
 (2) rate between active master connections and master connections no longer used