Collapse AllExpand All

2.2.6. B Channels Previous topic Parent topic Child topic Next topic

The following table provides an overview of the number of available B channels that are dependent on enabled features.

Table 9. Number of B channels dependent on enabled features

 
STMI2
NCUI2+
STMI4
NCUI4
STMIX
STMIY
2 DSP
(Q2316-X)
4 DSP
(Q2316-X10)
2 DSP
(Q2305-X35)
4 DSP
(2305-X40)
2 DSP
(Q2324-X500)
5 DSP
(Q2324-X511)
2 DSP
(Q2324-X)
5 DSP
(Q2324-X11)
(Q2343)
(Q2361)
Standards
60
120
60
120
60
120
60
120
120
120
QDC
56
112
56
112
60
120
60
120
120
120
SRTP
45
90
45
90
50
120
50
120
120
120
QDC+
SRTP
42
84
42
84
50
120
50
120
120
120
DMC
45
90
45
90
50
100
50
100
120
120
QDC+
DMC
42
84
42
84
50
100
50
100
120
120
DMC+
SRTP
32
63
32
63
40
100
40
100
120
120
QDC+
DMC
+SRTP
30
60
30
60
40
100
40
100
120
120

Important Notes for QDC

QDC is activated on the gateway via WBM and needs additional performance resources.
QDC is not automatically considered for channel reduction. Therefore the number of channels has to be adapted manual (depending on the type of the board) to the values mentioned in the table above when QDC is activated. If no adaption takes place performance problems will occur.

Automatic b channel reduction

Using the features for signaling and payload encryption (SPE) and also DMC, automatic b channel reduction is performed, i.e. the current values set are reduced by a fixed percentage. This percentage depends on the hardware used.
IMPORTANT:
The automatic b channel reduction is not performed with the feature QDC. This b channel reduction has to be done manually referring to Table 9, “Number of B channels dependent on enabled features”.
This reduction is not only calculated on board level but on function level. This means that the percentage values from above will be calculated per configured function.

Examples for single feature support (STMI2/STMI4):

  1. DMC is activated for HG 3550 on Q2324-X511
  2. DMC activated on Q2324-X511: reduction of the b channels of 17% (= minus 20 b channels)
    => Maximum number of available b-channels: 120-20=100
  3. SPE and DMC is activated for HG 3550 on Q2316-X.
  4. SPE activated on Q2316-X: reduction of the b channels of 25% (= minus 15 b channels)
    => 60-15=45
    DMC additionally activated on Q2316-X: reduction of the b channels of 25% (of the maximum number of available b channels / depending on the board and/or number of DSPs = minus 15 b channels)
    => Maximum number of available b-channels: 45-15=30

Example for multiple feature support (STMI2/STMI4):

  1. DMC is activated for 2 HG 3550 circuits with 40 b-channels on Q2324-X500. The remaining 20 b-channels are configured for HG 3530.
  2. SPE activated on Q2324-X500 for HG 3550: reduction of the b channels of 17% (of 40 b channels = minus 7 b channels )
    => Maximum number of available b-channels for HG 3550: 40-7=33
    The HG 3530 gateway cannot act as DMC endpoint. Therefore the 20 b channels won’t be reduced for HG 3530.
  3. SPE is activated for 2 HG 3550 circuits with 40 b-channels and HG 3530 for 20 b channels on Q2324-X500.
  4. SPE activated on Q2324-X500 for HG 3550: reduction of the b channels of 17% (of 40 b channels = minus 7 b channels)
    => Maximum number of available b-channels for HG 3550: 40-7=33
    SPE activated on Q2324-X500 for HG 3530: reduction of the b channels of 17% (of 20 b channels = minus 3 b channels)
    => Maximum number of available b-channels for HG 3530: 20-3=17
    These reduced b-channel values are the upper limit for path selection.
    The B channel number increases appropriately when features are deactivated.
    Summary:
    In the AMO BFDAT, only the maximum number of B channels can be configured. Using the AMO BCSU, the number of currently available B channels can be displayed and the B channels configured.
    The following tables provide an overview of the number of available B channels that are dependent on enabled features.