Problem description:
An HG 3500 is configured as a SIP trunking gateway. The parameters
for the connection to the Web Based Management of the board (AMO CGWB,
parameter MGNTIP and MGNTPN) and the backup server (AMO
CGWB, parameter BUSIP and BUSPN) have to be configured.
After a reset of the board or after a loadware update the IP addresses
(MGNTIP and BUSIP) are restored but not the port numbers
(MGNTPN and BUSPN). These parameter values are set to the
default value (in both cases „0“). Therefore a connection to the
backup server cannot be established anymore. The needed configuration
data for SIP trunking that has been configured in the WBM and has been
saved on the backup server cannot be restored. The SIP trunking connection
cannot be re-established again.
Solutions:
Check parameter in AMO CGWB and configure it again:
CHANGE-CGWB:MTYPE=CGW,LTU=<number>,SLOT=<number>,TYPE=MGNTDATA,MGNTPN=8000,BUS
PN=443;
Or save the configuration data in the local flash of the
board during installation of the board:
WBM > Maintenance > Config & Update > Save Local Configuration
for Upgrade
For a detailed description, see "OpenScape 4000 V, Gateways HG 3500
and HG 3575, Administrator Documentation" ().