2.16.2. Configuring Functional Blocks with the AMO BFDAT Previous topic Parent topic Child topic Next topic

Functional block 1

/* Functional block 1: Adding the IPDA function (HG3570)
ADD-BFDAT:FCTBLK=1,FUNCTION=HG3570,BRDBCHL=BCHAN120;
>>>>> IPDA with 120 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=1,FUNCTION=HG3570,BCHLCNT=120;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=1,ANSW=YES;

Functional block 2

/* Functional block 2: Adding the functions IPDA (HG3570), IP trunking (HG3550) and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=2,FUNCTION=HG3570&HG3550&HG3530,BRDBCHL=BCHAN;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=2,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with three units (=30 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=2,FUNCTION=HG3550,LINECNT=1,UNITS=3;
>>>>> HFA with 60 circuits with 60 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=2,FUNCTION=HG3530,LINECNT=60,BCHLCNT=60;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=2,ANSW=YES;

Functional block 3

/* Functional block 3: Adding the functions IPDA (HG3570), IP trunking (HG3550), WAML and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=3,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with three units (=30 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3550,LINECNT=1,UNITS=3;
>>>>> WAML
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=WAML,UNITS=3;
>>>>> HFA with 30 circuits with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3530,LINECNT=30,BCHLCNT=30;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=3,ANSW=YES;

Functional block 4

/* Functional block 4: Adding the functions IPDA (HG3570), IP trunking (HG3550), WAML and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=4,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3550,LINECNT=1,UNITS=1;
>>>>> WAML with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=WAML;
>>>>> HFA with 70 circuits with 70 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3530,LINECNT=70,BCHLCNT=70;
>>>>> End configuration of block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=4,ANSW=YES;

Functional block 5

/* Functional block 5: Adding the functions IPDA (HG3570), IP trunking (HG3550), WAML and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=5,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with 10 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=HG3550,LINECNT=1;
>>>>> WAML with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=WAML;
>>>>> HFA with 140 circuits with 70 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=HG3530,LINECNT=140,BCHLCNT=70;
>>>>> End configuration of block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=5,ANSW=YES;

Functional block 6

/* Functional block 6: Adding the functions IP trunking (HG3550) and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=6,FUNCTION=HG3550&HG3530,BRDBCHL=BCHAN120;
>>>>> IP trunking with one circuit with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=6,FUNCTION=HG3550,LINECNT=1,UNITS=3;
>>>>> HFA with 90 circuits with 90 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=6,FUNCTION=HG3530,LINECNT=90,BCHLCNT=90;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=6,ANSW=YES;

Functional block 7

/* Functional block 7: IP trunking, HFA subscriber function (HG3530) and reserve HFA subscriber (HG3530R)
IMPORTANT:
The reserved HFA B channels must be specified during configu­ration of the HG3530 function as subscriber B channels are not accepted during reservation.
ADD-BFDAT:FCTBLK=7,FUNCTION=HG3550&HG3530&HG3530R,BRDBCHL=BCHAN120;
>>>>> HFA with 80 circuits with 80 B channels and 20 reserve B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=7,FUNCTION=HG3530,LINECNT=80,BCHLCNT=100;
>>>>> Reserve HFA subscriber with 20 circuits
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=7,FUNCTION=HG3530R,LINECNT=20;
>>>>> IP trunking with 10 circuits with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=7,FUNCTION=HG3550,LINECNT=10,UNITS=1;

Displaying all functional blocks

DISPLAY-BFDAT;
H500:  AMO BFDAT STARTED
--------------------------------------------------------------------------------
| FCTBLK =  1    BRDBCHL: BCHAN120                    STATUS=      OK          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3570       1 LINES    UNITS ??  BCHLCNT 120  TOTAL BCHAN 120  |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK =  2    BRDBCHL : BCHL120                    STATUS=      OK          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3570       1 LINES    UNITS 30  BCHLCNT  30  TOTAL BCHAN  30  |
|  2nd FUNCT : HG3550       1 LINES    UNITS  3  BCHLCNT  30  TOTAL BCHAN  30  |
|  3rd FUNCT : HG3530      60 LINES    UNITS 60  BCHLCNT  60  TOTAL BCHAN  60  |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK =  3    BRDBCHL : BCHL120                    STATUS=      OK          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3570       1 LINES    UNITS 30  BCHLCNT  30  TOTAL BCHAN  30  |
|  2nd FUNCT : HG3550       1 LINES    UNITS  3  BCHLCNT  30  TOTAL BCHAN  30  |
|  3rd FUNCT : WAML         1 LINES    UNITS  3  BCHLCNT  30  TOTAL BCHAN  30  |
|  4th FUNCT : HG3530      30 LINES    UNITS 30  BCHLCNT  30  TOTAL BCHAN  30  |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK =  4    BRDBCHL : BCHL120                    STATUS=      OK          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3570       1 LINES    UNITS 30  BCHLCNT  30  TOTAL BCHAN  30  |
|  2nd FUNCT : HG3550       1 LINES    UNITS  1  BCHLCNT  10  TOTAL BCHAN  10  |
|  3rd FUNCT : WAML         1 LINES    UNITS  1  BCHLCNT  10  TOTAL BCHAN  10  |
|  4th FUNCT : HG3530      70 LINES    UNITS 70  BCHLCNT  70  TOTAL BCHAN  70  |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK =  5    BRDBCHL : BCHL120                    STATUS=    CONT          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3570       1 LINES    UNITS 30  BCHLCNT  30  TOTAL BCHAN  30  |
|  2nd FUNCT : HG3550       1 LINES    UNITS  1  BCHLCNT  10  TOTAL BCHAN  10  |
|  3rd FUNCT : WAML         1 LINES    UNITS  1  BCHLCNT  10  TOTAL BCHAN  10  |
|  4th FUNCT : HG3530     140 LINES    UNITS 70  BCHLCNT  70  TOTAL BCHAN  70  |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK =  6    BRDBCHL : BCHL120                    STATUS=      OK          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3550       1 LINES    UNITS  3  BCHLCNT  30  TOTAL BCHAN  30  |
|  2nd FUNCT : HG3530      90 LINES    UNITS 90  BCHLCNT  90  TOTAL BCHAN  90  |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK =  7    BRDBCHL : BCHL120                    STATUS=      OK          |
--------------------------------------------------------------------------------
|  1st FUNCT : HG3530      80 LINES    UNITS 80  BCHLCNT 100  TOTAL BCHAN 100  |
|  2nd FUNCT : HG3530R     20 LINES    UNITS 20  BCHLCNT   0  TOTAL BCHAN   0  |
|  3rd FUNCT : HG3550      10 LINES    UNITS 10  BCHLCNT  10  TOTAL BCHAN  10  |
--------------------------------------------------------------------------------
AMO-BFDAT-54        CONFIGURATION OF FUNCTIONAL BLOCKS FOR CGW BOARDS           
DISPLAY COMPLETED;
  <