Functional block 1
/* Functional block 1: Adding the IPDA function (HG3570)
ADD-BFDAT:FCTBLK=1,FUNCTION=HG3570,BRDBCHL=BCHAN120;
>>>>> IPDA with 120 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=1,FUNCTION=HG3570,BCHLCNT=120;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=1,ANSW=YES;
Functional block 2
/* Functional block 2: Adding the functions IPDA (HG3570), IP trunking
(HG3550) and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=2,FUNCTION=HG3570&HG3550&HG3530,BRDBCHL=BCHAN;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=2,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with
three units (=30 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=2,FUNCTION=HG3550,LINECNT=1,UNITS=3;
>>>>> HFA with 60 circuits with 60 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=2,FUNCTION=HG3530,LINECNT=60,BCHLCNT=60;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=2,ANSW=YES;
Functional block 3
/* Functional block 3: Adding the functions IPDA (HG3570), IP trunking
(HG3550), WAML and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=3,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with
three units (=30 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3550,LINECNT=1,UNITS=3;
>>>>> WAML
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=WAML,UNITS=3;
>>>>> HFA with 30 circuits with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3530,LINECNT=30,BCHLCNT=30;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=3,ANSW=YES;
Functional block 4
/* Functional block 4: Adding the functions IPDA (HG3570), IP trunking
(HG3550), WAML and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=4,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with
one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3550,LINECNT=1,UNITS=1;
>>>>> WAML with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=WAML;
>>>>> HFA with 70 circuits with 70 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3530,LINECNT=70,BCHLCNT=70;
>>>>> End configuration of block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=4,ANSW=YES;
Functional block 5
/* Functional block 5: Adding the functions IPDA (HG3570), IP trunking
(HG3550), WAML and HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=5,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit with
10 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=HG3550,LINECNT=1;
>>>>> WAML with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=WAML;
>>>>> HFA with 140 circuits with 70 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=5,FUNCTION=HG3530,LINECNT=140,BCHLCNT=70;
>>>>> End configuration of block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=5,ANSW=YES;
Functional block 6
/* Functional block 6: Adding the functions IP trunking (HG3550) and
HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=6,FUNCTION=HG3550&HG3530,BRDBCHL=BCHAN120;
>>>>> IP trunking with one circuit with
30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=6,FUNCTION=HG3550,LINECNT=1,UNITS=3;
>>>>> HFA with 90 circuits with 90 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=6,FUNCTION=HG3530,LINECNT=90,BCHLCNT=90;
>>>>> End configuration of this block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=6,ANSW=YES;
Functional block 7
/* Functional block 7: IP trunking, HFA subscriber function (HG3530)
and reserve HFA subscriber (HG3530R)
IMPORTANT:
The reserved HFA B channels must be specified
during configuration of the HG3530 function as subscriber B channels
are not accepted during reservation.
ADD-BFDAT:FCTBLK=7,FUNCTION=HG3550&HG3530&HG3530R,BRDBCHL=BCHAN120;
>>>>> HFA with 80 circuits with 80 B channels
and 20 reserve B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=7,FUNCTION=HG3530,LINECNT=80,BCHLCNT=100;
>>>>> Reserve HFA subscriber with 20 circuits
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=7,FUNCTION=HG3530R,LINECNT=20;
>>>>> IP trunking with 10 circuits with
one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=7,FUNCTION=HG3550,LINECNT=10,UNITS=1;
Displaying all functional blocks
DISPLAY-BFDAT;
H500: AMO BFDAT STARTED
--------------------------------------------------------------------------------
| FCTBLK = 1 BRDBCHL: BCHAN120 STATUS= OK |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3570 1 LINES UNITS ?? BCHLCNT 120 TOTAL BCHAN 120 |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK = 2 BRDBCHL : BCHL120 STATUS= OK |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3570 1 LINES UNITS 30 BCHLCNT 30 TOTAL BCHAN 30 |
| 2nd FUNCT : HG3550 1 LINES UNITS 3 BCHLCNT 30 TOTAL BCHAN 30 |
| 3rd FUNCT : HG3530 60 LINES UNITS 60 BCHLCNT 60 TOTAL BCHAN 60 |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK = 3 BRDBCHL : BCHL120 STATUS= OK |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3570 1 LINES UNITS 30 BCHLCNT 30 TOTAL BCHAN 30 |
| 2nd FUNCT : HG3550 1 LINES UNITS 3 BCHLCNT 30 TOTAL BCHAN 30 |
| 3rd FUNCT : WAML 1 LINES UNITS 3 BCHLCNT 30 TOTAL BCHAN 30 |
| 4th FUNCT : HG3530 30 LINES UNITS 30 BCHLCNT 30 TOTAL BCHAN 30 |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK = 4 BRDBCHL : BCHL120 STATUS= OK |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3570 1 LINES UNITS 30 BCHLCNT 30 TOTAL BCHAN 30 |
| 2nd FUNCT : HG3550 1 LINES UNITS 1 BCHLCNT 10 TOTAL BCHAN 10 |
| 3rd FUNCT : WAML 1 LINES UNITS 1 BCHLCNT 10 TOTAL BCHAN 10 |
| 4th FUNCT : HG3530 70 LINES UNITS 70 BCHLCNT 70 TOTAL BCHAN 70 |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK = 5 BRDBCHL : BCHL120 STATUS= CONT |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3570 1 LINES UNITS 30 BCHLCNT 30 TOTAL BCHAN 30 |
| 2nd FUNCT : HG3550 1 LINES UNITS 1 BCHLCNT 10 TOTAL BCHAN 10 |
| 3rd FUNCT : WAML 1 LINES UNITS 1 BCHLCNT 10 TOTAL BCHAN 10 |
| 4th FUNCT : HG3530 140 LINES UNITS 70 BCHLCNT 70 TOTAL BCHAN 70 |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK = 6 BRDBCHL : BCHL120 STATUS= OK |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3550 1 LINES UNITS 3 BCHLCNT 30 TOTAL BCHAN 30 |
| 2nd FUNCT : HG3530 90 LINES UNITS 90 BCHLCNT 90 TOTAL BCHAN 90 |
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
| FCTBLK = 7 BRDBCHL : BCHL120 STATUS= OK |
--------------------------------------------------------------------------------
| 1st FUNCT : HG3530 80 LINES UNITS 80 BCHLCNT 100 TOTAL BCHAN 100 |
| 2nd FUNCT : HG3530R 20 LINES UNITS 20 BCHLCNT 0 TOTAL BCHAN 0 |
| 3rd FUNCT : HG3550 10 LINES UNITS 10 BCHLCNT 10 TOTAL BCHAN 10 |
--------------------------------------------------------------------------------
AMO-BFDAT-54 CONFIGURATION OF FUNCTIONAL BLOCKS FOR CGW BOARDS
DISPLAY COMPLETED;
<