The gateway starts up using its default configuration data. No retry
to reach the backup server is executed.
Loadware Update via HDLC
Same procedures as normal restart. When upgrading via HDLC the board
can’t have stored the current configuration data to the local flash
(TFFS).
Configuration data is essentially no longer lost when a loadware update
is performed via HDLC as a backup file is created on the local flash
whenever data is saved in the WBM.
Loadware Update via OpenScape 4000 Assistant / WBM
After activating the new loadware the gateway will be automatically
rebooted. The new gateway loadware is loaded. The new loadware image
loads the previously stored configuration data. The data on the backup
server can not be more up-to-date, therefore it is not taken into consideration.
Loadware Update via OpenScape 4000 Assistant / WBM: backup server
not configured
Same as „Loadware Update via OpenScape 4000 Assistant / WBM“.
Loadware Update via OpenScape 4000 Assistant / WBM: backup server
configured but not reachable (via IP)
Same as „Loadware Update via OpenScape 4000 Assistant / WBM“.
Loadware Update via OpenScape 4000 Assistant / WBM: backup server
configured and reachable, but no backup with configuration data is stored/found
Same as „Loadware Update via OpenScape 4000 Assistant / WBM“.
Loadware Update via OpenScape 4000 Assistant / WBM: backup server
configured and reachable, but on the backup server an older configuration
than the current one is found
Same as„Loadware Update via OpenScape 4000 Assistant / WBM“.