2.11.1. General description Previous topic Parent topic Child topic Next topic

The STMIX can be re-flashed in case the board is not booting or not becoming READY in RMX.
The process can also be used to factory reset an STMIX board. All customer saved data will be erased from the board.

Hardware and cabling requirements

  • PC or Notebook with Windows OS: A connection must be established between the PC/Notebook and the STMIX board via a LAN cable connected to STMIX LAN1.
    In the example provided in this document the STMIX uses the 192.0.2.101 IP address. It is strongly recommended for the PC to use 192.0.2.100 with netmask 255.255.255.0. Do NOT configure any other IP address on the same interface to avoid issues.
    INFO:
    It is possible to use a secondary PC network interface if available.
  • USB cable, type A to type B cable (e.g. USB printer cable): connect the Windows PC via USB (type A) and the STMIX via USB (type B).
  • STMIX in OpenScape 4000, any type shelf: AP37009, AP370013, LTUW, etc.

Software requirements

  • DHCP Server + TFTPD Server: e.g. tftpd64.exe from https://tftpd64.software.informer.com/download/
    INFO:
    Use the 32 bit version in case of 32 bit Windows OS.
  • HTTP fileserver: e.g. HFS.exe from https://www.rejetto.com/hfs/?f=dl
  • Decompression tool which supports .exe and .gz unzipping: e.g. 7zip.
  • SSH client (e.g. Putty) for SSH access to OpenScape 4000 and for COM port access to STMIX via USB port.
  • SFTP client (e.g. WinSCP) for downloading files from the OpenScape 400 platform.
  • STMIX USB Driver from OS4K Installation ISO: e.g. OS4K_V10_R0.28.0_InstallImage.iso\DriversAndTools\STMIX_USB_Serial_Console_Driver\
  • JeOS image for STMIX, generated on the OS4K Linux platform.
    INFO:
    Minimum required OS4K PLT version: V8 R2.22.9 or V10 R0.28.5.